List of delivery limits for the Siemens

(Mechanical)
Limit ID Siemens Drawing Design pressure bar(g)
LBQ30/10 BPS-LBQ-15040 8.5

- BPS-LCC-15054 3

- BPS-LCC-15054 3

- BPS-LCC-15054 3
LCA70/05 BPS-LCC-15054 25
LCA75/05 BPS-LCC-15054 25
LCA75/10 BPS-LCC-15054 5
LCC10/05 BPS-LCC-15054 3
LCC10/15 BPS-LCC-15054 3
LCC10/20 BPS-LCC-15054 3
LCC10/25 BPS-LCC-15054 3
LCC10/30 BPS-LCC-15054 3
LCC10/35 BPS-LCC-15054 3
LCJ10/05 BPS-LCC-15054 3
LCJ11/10 BPS-LCC-15054 3
LCJ20/10 BPS-LCC-15054 3

- BPS-LCC-15055 3

LCA80/10 BPS-LCC-15055 25
LCA85/05 BPS-LCC-15055 5
LCA85/10 BPS-LCC-15055 25
LCC20/05 BPS-LCC-15055 3
LCC20/10 BPS-LCC-15055 3
LCC20/15 BPS-LCC-15055 3
LCC20/20 BPS-LCC-15055 3
LCC20/25 BPS-LCC-15055 3
LCC20/35 BPS-LCC-15055 3
LCJ20/05 BPS-LCC-15055 3
LAB30/05 BPS-LCC-15056 230
LAB40/05 BPS-LCC-15056 230
LAD10/05 BPS-LCC-15056 17
LAD10/10 BPS-LCC-15056 6
LAD10/15 BPS-LCC-15056 17
LAD10/20 BPS-LCC-15056 17
LAD10/25 BPS-LCC-15056 17
LAD10/30 BPS-LCC-15056 17
LCH10/05 BPS-LCC-15056 17
LCH20/10 BPS-LCC-15056 17
- BPS-LCC-15057 6
LAB40/10 BPS-LCC-15057 230
LAB50/05 BPS-LCC-15057 230

LAB50/10 BPS-LCC-15057 12
LAB50/15 BPS-LCC-15057 230
LAD20/05 BPS-LCC-15057 29
LAD20/15 BPS-LCC-15057 29
LAD20/20 BPS-LCC-15057 29
LAD20/25 BPS-LCC-15057 29
LAD20/30 BPS-LCC-15057 29
LCH20/05 BPS-LCC-15057 29

LBA10/25 BPS-MAB-15042 156


MAB10/05 BPS-MAB-15042 0.7
MAL10/51 BPS-MAB-15042 1
LBQ10/10 BPS-MAL-15044 0.5
LBQ10/15 BPS-MAL-15044 0.5
LBQ20/15 BPS-MAL-15044 0.5
LBQ20/20 BPS-MAL-15044 0.5
LBQ30/15 BPS-MAL-15044 0.5
LBQ30/20 BPS-MAL-15044 0.5
MAL10/135 BPS-MAL-15044 0.5
MAL10/90 BPS-MAL-15044 1
MAL10/91 BPS-MAL-15044 1
MAL60/05 BPS-MAL-15059 0.7
MAL60/06 BPS-MAL-15059 0.7

MAL60/07 BPS-MAL-15059 0.7


MAL65/05 BPS-MAL-15059 15
MAL65/10 BPS-MAL-15059 16
MAL65/15 BPS-MAL-15059 16
MAM10/10 BPS-MAM-15045 25

MAM10/15 BPS-MAM-15045 25
MAM10/25 BPS-MAM-15045 1
MAM10/30 BPS-MAM-15045 25
MAM10/35 BPS-MAM-15045 25
MAM10/40 BPS-MAM-15045 1
MAM10/45 BPS-MAM-15045 1
LCE10/15 BPS-MAN-15058 25
LCE10/20 BPS-MAN-15058 25
LCE10/25 BPS-MAN-15058 25
MAN30/05 BPS-MAN-15058 156
MAN30/10 BPS-MAN-15058 5

MAN30/15 BPS-MAN-15058 156


MAN30/20 BPS-MAN-15058 5
MAN30/25 BPS-MAN-15058 5
MAV10/05 BPS-MAV-15046 ATM
MAV10/10 BPS-MAV-15046 1
MAV10/15 BPS-MAV-15046 ATM
MAV10/20 BPS-MAV-15046 1
MAV10/40 BPS-MAV-15046 ATM
MAV30/05 BPS-MAV-15046 6
MAV30/10 BPS-MAV-15046 6
MAV30/15 BPS-MAV-15046 6
MAV30/20 BPS-MAV-15046 6
MAV30/25 BPS-MAV-15046 6
MAV30/30 BPS-MAV-15046 6
MAV30/35 BPS-MAV-15046 6
MAV40/05 BPS-MAV-15046 3
MAV40/10 BPS-MAV-15046 3
MAV40/15 BPS-MAV-15046 3
MAV40/20 BPS-MAV-15046 3
MAV40/25 BPS-MAV-15046 3
MAV10/50 BPS-MAV-15047 0.5
MAV15/05 BPS-MAV-15048 ATM
MAV15/10 BPS-MAV-15048 4
MAV15/15 BPS-MAV-15048 4
MAV15/20 BPS-MAV-15048 4

LBA12/05 BPS-MAW-15049 156


LCA32/05 BPS-MAW-15049 25
MAW10/25 BPS-MAW-15049 5
MAX10/05 BPS-MAX-15050 ATM

MAX35/05 BPS-MAX-15050 160


MAX30/05 BPS-MAX-15050 10
MAX30/10 BPS-MAX-15050 6
MAX30/15 BPS-MAX-15050 6

MKA10/05 BPS-MKA-15052 6

MKA10/05 BPS-MKA-15052 6
MKA10/10 BPS-MKA-15052 6

MKA10/15 BPS-MKA-15052 6

MKA10/20 BPS-MKA-15052 6

MKA10/25 BPS-MKA-15052 6

MKA10/30 BPS-MKA-15052 6

MKA10/35 BPS-MKA-15052 6

MKA10/40 BPS-MKA-15052 6

MKA10/45 BPS-MKA-15052 6

MKA10/50 BPS-MKA-15052 6
(Mechanical)
Design temperature °C Notes
195

150 If applicable, shell safety valve outlet


Vent from pump, as per project
150 meeting 4.12.2013
Vent from pump, as per project
150 meeting 4.12.2013
150
150
150
150
150
150
150
150
150 Client design 16 bar(g), 150°C
150
150 Client design 25 bar(g), 150°C
150

150 If applicable, shell safety valve outlet

150
150
150
150
150
150
150
150
150 Client design 16 bar(g), 150°C
150
210
210
275
275
275
210
210
275
210
275 Client design 27 bar(g), 240°C
240 If applicable, shell safety valve outlet
240
240

240
240
335
335
240
240
335
240
Live steam design values are 136,5
545 bar(g), 553°C
150
150
235
235
285
285
170
170
485
100
100
410
120
(Seems that valve is missing in your
120 PID)
150
90
90
120

Siemens should inform in which


condition 1 bar(g) steam can create
224 224°C condensate in tube side
200
120
120
200
200
120
120
120
Live steam design values are 136,5
545 bar(g), 553°C
500
Live steam design values are 136,5
545 bar(g), 553°C
500
500
80
80
80
80
80
80
100 As per project meeting 4.12.2013
100 As per project meeting 4.12.2013
100 As per project meeting 4.12.2013
100 As per project meeting 4.12.2013
80
80
80
80
80
80
80
100
80
80
80
80
Live steam design values are 136,5
545 bar(g), 553°C
120
340
80

There is no note marked. Do we need


80 to direct terminal point somewhere
80
100 As per project meeting 4.12.2013
100 As per project meeting 4.12.2013

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)
As per project meeting 4.12.2013,
please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)

As per project meeting 4.12.2013,


please check possibility to increase
90 for 10 bar(g)
Values confirmed by Siemens (y/n)
yes

not applicable

not applicable

not applicable
yes
yes
yes; 2" class 150 flange connection
yes
yes
yes
yes
yes
yes; Nozzle A106 GrB STD
yes
yes; Nozzle A106 GrB STD
yes

not applicable

yes
yes; 2" class 150 flange connection
yes
yes
yes
yes
yes
yes
yes; Nozzle A106 GrB STD
yes
yes
yes
yes
yes; 4" class 150 flange connection
yes
yes
yes
yes
yes
yes
yes
yes
No, see change red marked.
2" class 150 flange connection
yes
yes
no, see change red marked
no, see change red marked
no, see change red marked
yes
yes

yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes

yes
yes
in clarification; probably ok
in clarification; probably ok
yes

yes.
224°C is in order to avoid damage by locked water in
the condenser.
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes

yes
yes
yes
yes
yes
yes
yes
yes
yes
no, see change red marked
no, see change red marked
no, see change red marked
no, see change red marked
no, see change red marked
no, see change red marked
yes
yes
yes
yes
yes
yes
no, see change red marked
yes
yes
yes

yes
yes
yes
yes

No action needed. This is filling connection


yes
no, see change red marked
no, see change red marked

6 bar g, yes

6 bar g, yes
6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes

6 bar g, yes