Control Unit Cerberus FIT FC360 - Addressable Fire Control Panels

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

© Siemens 2020

are binding only when they are expressly agreed upon in the concluded contract.
course of further development of the products. The requested performance features
specifically reflect those described, or which may undergo modification in the
contains general descriptions and/or performance features which may not always
Subject to changes and errors. The information given in this document only
Article no. SI_0195_EN (Status 12/2020)

United States
Alpharetta, GA 30005
100 Technology Drive

Siemens Industry Inc.


For the U.S. published by

Tel +41 58 724 24 24


Switzerland
6300 Zug
Theilerstrasse 1a
Global Headquarters
Smart Infrastructure

Siemens Switzerland Ltd


Published by

siemens.com/smart-infrastructure
Creating environments that care.

and supports sustainable development.


It helps our customers to thrive, communities to progress

people and helps customers to better use resources.


an ecosystem that intuitively responds to the needs of
We work together with customers and partners to create

we live and work.


buildings and industries to adapt and evolve the way
Smart Infrastructure intelligently connects energy systems,
siemens.com/cerberus-fit
Planning Tool
Cerberus FIT
FC360 –
Cerberus FIT FC360 – addressable fire control panels Control unit

1-loop panels 2-loop panels Hardware components


– 1 loop or 2 stubs – 2 loop or 4 stubs
– Number of addresses: max. 126 – Number of addresses: max. 256 8 Legend
9
Shared properties 5 1 Power supply 8 Mains fuse
– Total current capacity: max. 2.5 A
2 Space for batteries 9 Main board connectors:
– 4 programmable inputs/outputs
– 2 collective sounder circuits
(DC 24 V/max. 0.1 A and 0.2 A in total) 3 Mainboard
– 24 V auxiliary outputs
– 3 programmable potential-free relay outputs
4 3 1 4 Output card (4M) (optional) – 4 programmable inputs/outputs
(DC 60 V/max. 2.0 A)
– 3 programmable relay outputs
– 2 collective sounder circuits (DC 24 V/max. 0.5 A) 6 10 5 Space for RS232/485 module
– Loop connector
– Auxiliary power output (DC 24 V/max. 0.2 A) 7 (optional)
10 Ethernet connector
6 User interface (PMI)
2
11 Detachable door
7 Space for options:
Fire control panel Fire control panel Fire control panel Fire control panel
– Evacuation module (NL)
(1L, Compact) FC361-ZZ (1L, Comfort) FC361-ZA (2L, Compact) FC362-ZZ (2L, Comfort) FC362-ZA
– LED indicator (32 zones)
– Housing: 402x372x132 mm – Housing: 402x372x211 mm – Housing: 402x372x132 mm – Housing: 402x372x211 mm 11
– Key switch/key switch (Nordic)
– Batteries: max. 2x 12 V, 12 Ah – Batteries: max. 2x 12 V, 25 Ah – Batteries: max. 2x 12 V, 12 Ah – Batteries: max. 2x 12 V, 25 Ah
Order no.: S54433-C112-A1 Order no.: S54433-C111-A1 Order no.: S54433-C119-A1 Order no.: S54433-C120-A1

Options

LED indicator (32 zones) Evacuation module (NL) Key switch Key switch (Nordic) Output card (4M) RS232 module (isolated) RS485 module (isolated)
FTO3603-Z1 FTO3601-H1 FCA3601-Z1 FCA3603-Z1 FCA3602-Z1 FCA2001-A1 FCA2002-A1
– Visual fire zone indication – Special option for The Netherlands – Standard key switch to provide – Special key switch (Nordic) to pro- – 4 configurable monitored – Communication module for –C
 ommunication module for
– Up to 32 fire zones – Independent cont rol of EVAC zone level 2 (user) access on panel vide level 2 (user) access on panel outputs (DC 24 V) peripheral devices with RS232 peripheral devices with RS485
Order no.: S54433-B118-A1 – Acc. NEN 2575 Order no.: S54433-N113-A1 Order no.: S54433-N115-A1 – Output current per output: 1.0 A interface (e.g. event printer interface
Order no.: S54433-B116-A1 – Max. current of output card: 2.0 A DL3750+) Order no.: A5Q00009923
Order no.: S54433-A114-A1 Order no.: A5Q00005327

Note: Unit can be powered from the


integral power supply or from an
additional external power supply.

FC360 Panel Configurator (online) Alarming highlights


Panel configuration in three easy steps. In the event of a fire it is essential to alert and evacuate people as fast as possible. A wide product portfolio range offers alarm devices for acoustic and optical alarming.
All devices are loop powered and constantly monitored.
The online tool is used to configure the panel on site. The panel has an integrated Web server that can be accessed with a Web browser. No additional software is needed.
The TCP/IP connection to the panel is established via the Web address fc360.siemens.com.
Sounder Beacon

1 Auto configuration 2 Modify 3 Apply & done The sounder creates an acoustic alarm signal in case of an event. All devices offers a broad
range of tone patterns.
Addressing two senses – an optical and an acoustical signal – speeds up the alert and evacua-
tion process. We increase the awareness of the optical signal with a high flash intensity and a
The acoustic perception is outstanding because all tones are synchronized. very short pulse length. The device has multiple options for brightness which can be adjusted
FC360 Panel Configurator – Certified for acoustic alarming according EN 54-3 according to the room size.
Apply – 3 different sound levels are selectable (minimum / medium / maximum) – Certified for optical alarming according EN 54-23
Panel –A dditional light intensity setting (supplementary optical indication) designed for system
– 16 integrated tone patterns
FC360 Panel Configurator extensions or migration.
Click Apply button
TCP/IP connection fc360.siemens.com Modify configuration
Wall devices
online at the site with
– Data from all connected detectors and peripheral
the FC360 Panel
devices are automatically configured
Configurator
– Devices are automatically assigned to zones
– Instant fire protection during the construction phase Coverage
volume

Voice
Category W – wall mounting
The devices with voice messages are able to play a precise voice instruction for different events
Detection and control view Cause and effect matrix FC360 Desktop Editor Alarm
in the building. With help of a voice message, the evacuation process is faster and the building
occupants receive clear instructions.
White LED Red LED
High: W-3.2-10 High: W-2.8-8.8
(offline) – Certified for acoustic alarming according EN 54-3. Mid: W-2.4-7.5 Mid: W-2.4-7.5
Low: O-2-6.2 Low: O-2-6.2
– Languages (15 integrated, 2 customizable)
The FC360 Desktop Editor is a tool for – Message categories (3 predefined): EVAC FIRE, EVAC EMERGENCY, TEST
O = Open category: Wall mounted, cubic coverage as category W
viewing the system’s configuration
offline as well as making text or cause- Tone Voice message Voice message (optional) Ceiling devices
and-effect changes.
In addition, the tool provides installers Language 1 Language 2
with self-learning opportunities where x

they can create their own “virtual” sys-


tem. This quickly builds solid expertise Languages (15 integrated, 2 customizable) Customer-specific voice message
y Coverage
and experience and reduces training – English – Finish 1. Order the service “Conversion of volume

costs and effort. – German – Danish voice message FDSS227” to create a


– French – Polish customer-specific audio library Category C – ceiling mounting
The FC360 configuration tool is simple to understand and use. Most systems require all alarming devices and control outputs – Italian – Portuguese
– Spanish – Turkish 2. Order customer-specific devices White LED Red LED
The connected devices are listed in a table in their order of wir- to operate with any fire. This operation is available by default. Download High: O-4-15 High: C-3-12
– English UK – Russian (..-C) with custom audio library ID
ing, allowing the user to easily visualize the devices as installed. Where more complex controls are required, the FC360’s the FC360 – Dutch – Custom language 1 Mid: C-3-12 Mid: C-3-10
Outputs and sounders can be assigned into one of 32 control or unique cause-and-effect matrix makes any required changes Desktop – Sweden – Custom language 2
Low: O-2.5-6.5 Low: O-2.5-6.5

evacuation zones and an appropriate description text (e.g. “door easy and logical. Editor – Norwegian
O = Open category: Ceiling mounted, cylindrical coverage as category C
release”) can be added for more clarity.
Cerberus FIT FC360 – compatible C-NET devices
Input/output module
FDCIO361
–1
 monitored input
(not invertible)
Fire detectors Detector base DB721 Detector base DB722 Flame detector Linear smoke detector
Relay outputs:
Fire control panel FC361-ZZ – Screw clamp terminals – Screwless terminals base FDFB291 base FDLB291
–1 output
Order no.: S54433-C112-A1 Order no.: S54319-F11-A1 – Integrated rubber seal Order no.: A5Q00003310 Order no.: A5Q00003941
–R
 elay output DC 30 V/2 A
Fire control panel FC361-ZA Order no.: S54319-F19-A1
Detector base DB721 rated
Order no.: S54433-C111-A1 Conventional line – Can be configured as moni-
or Order no.: S54319-F11-A1
Fire control panel FC362-ZZ Conventional tored, but a separate DC 24 V
Order no.: S54433-C119-A1 detectors
power supply is required
Fire control panel FC362-ZA ASA neural fire
Order no.: S54312-F102-A1
Order no.: S54433-C120-A1 Flame detector FDF241-9 detector OOH740
– For inside and outside Order no.: S54320-F7-A3
applications Linear smoke detector Input module FDCI361
– Three infrared sensors FDL241-9
–1
 monitored input
Order no.: A5Q00002298 Air sampling
Order no.: A5Q00003006 (not invertible)
smoke detection kit
FDBZ290 Order no.: S54312-F101-A1

Order no.: S54319-S32-A1


Input/output module
FDCIO221
1 collective or –1
 monitored input
Zone module
Floor repeater Shared properties FT2010 and FT2011: ASA neural fire ASA neural fire and Multi-sensor fire Smoke detector OP360 Heat detector HI360 (max + RoR) Heat detector
up
to conventional
(invertible)
10
0m FDCI723 detector line
terminal – Backlit display with plain text detector OOH740 CO detector OOHC740 detector OH360 One parameter set Two parameter sets (rate-of-rise HI722 (max) Relay outputs:
FT2010-A1 (6 lines of 40 characters each) Two optical sensors, Two optical sensors, Combined optical and and static) One parameter set
Order no.: Long-distance reflector – 1 output
Order no.: – Power supply and communication two heat sensors, two heat sensors, one thermal sensors, one S54310-F101-A1 Order no.: S54310-F104-A1 (static) DLR1191 (Prism) –R elay output DC 30 V/2 A
A5Q00014104 (individual addressed) via C-NET, three parameter sets carbon monoxide sen- parameter set Order no.: For distances between rated
additional DC 24 V feed possible Order no.: sor, three parameter sets Order no.: S54310-F102-A1 S54310-F3-A1 20 and 100 meters
Fire
control – Can be configured as
Floor repeater monitored, but a separate
– 207x282x79 mm (HxWxD) S54320-F7-A3 Order no.: Order no.: BPZ:4787710001
display Multi-sensor fire Smoke detector OP720 Heat detector HI720 (max + RoR) DC 24 V power supply is
– Max. 3 FT2010/FT2011 per FC361 S54320-F8-A3
FT2011-A1 detector OH720 Two parameter sets Two parameter sets (rate-of-rise required
Order no.: Combined optical and Order no.: S54310-F1-A1 and static)
Order no.: S54312-F2-A1
A5Q00017706 thermal sensors, two Order no.: S54310-F4-A1
Detector base accessories parameter sets C-NET
Order no.: S54310-F2-A1 The C-NET is a modern, multi-purpose bus system. Input module FDCI221
Alarm indicator Detector base seal RS720 Base attachment wet It allows rapid, fail-safe communi­cation between the Cerberus – 1 monitored input
(addressable) Order no.: S54319-F8-A1 BA721 FIT/PRO bus elements and the fire control panel. (invertible)
FDCAI221 Order no.: S54319-F29-A1 Characteristics: Order no.: S54312-F1-A1
Order no.: – Uses all cable types (shielded or unshielded)
Designation plate FDBZ291
S54370-F10-A1 4 isolated
Order no.: A5Q00002621 Detector heating – Integrates star-shaped cable networks without control inputs Input/output module
FDBH291 modifications to cable network Fire FDCIO222
damper
Order no.: A5Q00004439 – Acoustic and visual signaling on the loop – 4 monitored inputs
Detector locking device LP720
Alarm indicator FDAI92 Alarm indicator Alarm indicator – Up to 126 bus elements on one loop 4 isolated Relay outputs:
Order no.: S54319-F9-A1 control outputs
Protection cage Order no.: S54370-F3-A1 FDAI91 FDAI93 – Cable lengths up to 3.3 km
Fire
control – 4 potential-free working/
4 isolated
DBZ1194 Order no.: Order no.: Power supply FP120 Housing FDCH221 control inputs
rest contacts
Additional frame AI330 – 2-wire loop
Base attachment BA720 Order no.: BPZ:4677110001 S54370-F9-A1 S54370-F5-A1 Order no.: S54400-S122-A1 IP65 Contact loading:
Order no.: BPZ:3169430001 – Integrated isolator in every loop participant
Order no.: S54319-F20-A1 Order no.: S54312-F3-A1 – AC 250 V/4 A
– DC 30 V/4 A
Order no.: A5Q00002369

Input module FDCI222


Alarm equipment for audible and visible alarming – 4 monitored inputs
Base (ceiling mounting) Base deep (ceiling mounting)
Sounder base DBS720 Base (wall mounting) Base deep (wall mounting, IP65) FDB228 FDB229 Order no.: A5Q00001984
Sound level: 88 dBA/1 m FDB226-R FDB227-R Order. no.: S54364-B5-A1 Order. no.: S54364-B6-A1
Order. no.: S54364-B1-A1 Order. no.: S54364-B3-A1
Order no.: S54319-F5-A1 Input/output module
Base (wall mounting) Base deep (wall mounting, IP65) FDCIO224
FDB226-W FDB227-W
Order. no.: S54364-B2-A1 Order. no.: S54364-B4-A1 With approval on VdS
Manual call points and accessories extinguishing interface
– 4 monitored inputs
Manual call point Manual call point Manual call point Manual call point Manual call point Manual call point Manual call point
Relay outputs:
Alarm Alarm Alarm FDM365-RP FDM221 FDM225 FDM226 FDM231-RP FDM224 FDM223
– 4 potential-free working/
Resettable, available in Standard, available Resettable, available Resettable and IP66, Standard, available IP44 or IP64, with direct IP44 or IP64, with indirect
rest contacts
red, and can be used for in different colors in red, and can be used available in red in red operation, available in alarm actuation, available
flush mounting for flush mounting different colors in different colors Contact loading:
– AC 250 V/4 A
– DC 30 V/4 A
Order no.: A5Q00002369

Manual call point with Manual call point with Manual call point with Manual call point
Sounder Voice sounder Sounder beacon Sounder beacon Standard voice Customized voice Sounder beacon Standard voice Customized Voice resettable plastic resettable plastic resettable plastic complete
FDS364-R FDS225-R FDS366-RR FDS226-RR messages messages base FDSB226-WR messages Messages element FDM365-RP element FDM225-RP element incl. back box Order no.: S54311-F11-A1
Housing red Housing red Housing red / LED red Housing red / LED red Voice sounder beacon Voice sounder beacon LED red Voice sounder beacon Voice sounder beacon FDM226-RP
Sound level: Sound level: maximum only O-2-6.2 / W-2.4-7.5 / O-2.5-6.5 / C-3-10 / Order no.: Order no.:
Order. no.: FDS227-RR FDS227-RR-C base FDSB227-WR base FDSB227-WR-C S54311-F111-A1
maximum only W-2.4-7.5 W-2.8-8.8 C-3-12 A5Q00012020 Order no.: A5Q00013436
S54364-F3-A1 Housing red / LED red Housing red / LED red LED red LED red
Order no.: Voice sounder Order. no.: S54364-F105-A1 Order. no.: S54364-F5-A1 O-2-6.2 / W-2.4-7.5 / O-2-6.2 / W-2.4-7.5 / Order. no.: O-2.5-6.5 / C-3-10 / O-2.5-6.5 / C-3-10 / Electronic switching Manual call point with Manual call point with Electronic switching Electronic switching Electronic switching
S54364-F101-A1 FDS225-W Sounder beacon Sounder beacon W-2.8-8.8 W-2.8-8.8 S54364-F13-A1 C-3-12 C-3-12 unit FDME221 glass plate FDM225-RG glass plate incl. back unit incl. key FDMK231 unit FDME224 unit FDME223
Sounder Housing white FDS366-RW FDS226-RW Order. no.: S54364-F9-A1 Order. no.: S54364-F9-A2 Sounder beacon Order. no.: Order. no.: Order no.: Order no.: box FDM226-RG FDME231 Order no.: A5Q00009392 Order no.:
FDS364-W Housing red / LED white Housing red / LED white base FDSB226-WW S54364-F15-A1 S54364-F15-A2
Order. no.: Voice sounder beacon Voice sounder beacon A5Q00002451 A5Q00013434 Order no.: Order no.: S54311-B14-A1 A5Q00003087
Housing white Sound level: maximum only O-2-6.2 / W-2.4-7.5 / FDS227-RW FDS227-RW-C LED white Voice sounder beacon Voice sounder beacon
S54364-F4-A1 A5Q00013435
Sound level: W-2.4-7.5 W-3.2-10 Housing red / LED white Housing red / LED white O-2.5-6.5 / C-3-12 / base FDSB227-WW base FDSB227-WW-C Housings: Housings with glass and key
maximum only Order. no.: S54364-F106-A1 Order. no.: S54364-F6-A1 O-2-6.2 / W-2.4-7.5 / O-2-6.2 / W-2.4-7.5 / O-4-15 LED white LED white Housing red (FDM224 and FDM223):
Order no.: Sounder beacon Sounder beacon W-3.2-10 W-3.2-10 Order. no.: O-2.5-6.5 / C-3-12 / O-2.5-6.5 / C-3-12 / with key FDMH291-R Housing red FDMH293-R
S54364-F102-A1 FDS366-WR FDS226-WR Order. no.: S54364-F10-A1 Order. no.: S54364-F10-A2 S54364-F14-A1 O-4-15 O-4-15
Order no.: Order no.: A5Q00004023
Sounder Housing white / LED red Housing white / LED red Voice sounder beacon Voice sounder beacon Order. no.: Order. no.: A5Q00002217
FDS224-R Sound level: maximum only O-2-6.2 / W-2.4-7.5 / S54364-F16-A1 S54364-F16-A2 More color options (yellow,
FDS227-WR FDS227-WR-C
Housing red W-2.4-7.5 W-2.8-8.8 More color options green, blue and orange) are
Housing white / LED red Housing white / LED red
Order. no.: Order. no.: S54364-F107-A1 (yellow, green and available
Order. no.: S54364-F7-A1 O-2-6.2 / W-2.4-7.5 / O-2-6.2 / W-2.4-7.5 /
S54364-F1-A1 W-2.8-8.8 W-2.8-8.8 blue) are available Housing red FDMH297-R
Sounder beacon Sounder beacon
Sounder FDS366-WW FDS226-WW Order. no.: S54364-F11-A1 Order. no.: S54364-F11-A2
Mounting Base (ceiling mounting) Order no.: S54311-B7-A1
FDS224-W Housing white / LED white Housing white / LED white Voice sounder beacon Voice sounder beacon example FDB228
Housing white Sound level: maximum only O-2-6.2 / W-2.4-7.5 / Accessories: Accessories: Accessories: Accessories: Accessories: Accessories
FDS227-WW FDS227-WW-C
W-2.4-7.5 W-3.2-10 Back box FDMH295-R Protective cover Back box FDMH295-R Protective cover Back box red (for FDM224 and FDM223):
Order. no.: Housing white / LED white Housing white / LED white Sounder beacon base
S54364-F2-A1 Order. no.: S54364-F108-A1 Order. no.: S54364-F8-A1 O-2-6.2 / W-2.4-7.5 / O-2-6.2 / W-2.4-7.5 / FDSB226-WR Order no.: A5Q00013437 FDMC291 Order no.: A5Q00013437 FDMC295 FDMH231-S-R Protection seal DMZ1197-AD
W-3.2-10 W-3.2-10
Back box with holes and Order no.: Back box with holes and Order no.: A5Q00013440 Order no.: S54311-B12-A1 Order no.: BPZ:5470680001
Order. no.: S54364-F12-A1 Order. no.: S54364-F12-A2 With detector Without detector A5Q00001644
grommet FDMH295-S grommet FDMH295-S Screwed cable gland Protective cover DMZ1197-AC
Detector base Order no.: A5Q00013438 Order no.: A5Q00013438 M20 x 1.5 Order no.: BPZ:5223550001
Conversion of voice DB721 Protective cover Protective cover Order no.: A5Q00004478 Locking plug M20 (1 hole)
Shared characteristics Legend
message FDSS227 FDMC295 FDMC295 Back nut M20 Order no.: A5Q00006735
– Up to 13 different tones, incl. “evacuate” as specified in DIN 33404-3
Service to convert custom Fire detector Ready-to-go
– Different volume and sound for prealarm and main alarm Order no.: A5Q00013440 Order no.: A5Q00013440 Order no.: A5Q00004479
audio message text Blanking plate Cerberus FIT devices
– Without additional power supply
Order. no.: L54364-Y1-A1 FDBZ298
– Integrated line separator C-NET
Order. no.: S54364-B8-A1

Cerberus FIT FC360 – application examples ASA parameter sets for diverse application areas

5
Faster fire detection with ASAtechnology
Heat detectors are needed in many areas due to the potential for false alarms. However, heat detection provides
3 significantly less protection. The ASA neural fire detector OOH740 with its dual optical chamber design allows advanced
1 smoke detection to be offered where others can only offer heat detection.

6 1 Two IR light sources


4
2 Dispersion of light rays by smoke particles
2
3 IR receiver
1
4 Patented labyrinth
5 Temperature sensors

5 6 CO sensor for OOHC740

Contact your local sales office for more information or application support.

In schools and In factories In hotels and In shops


nursing homes homes

Selectable parameter sets:


Benefits at a glance Fast Response Balanced Suppression Separate CO sensor
• Areas where speed of detection • Provides a good balance between • Areas requiring smoke detection • Provides fire-independent detection
1. Maximized fire safety 3. Cost and time efficient is the priority and where there effective smoke detection and false where a high number of false alarm of toxic carbon monoxide due to
• Reliable and early detection • Training efforts reduced are few false alarm sources alarm resistance sources may be expected, including incomplete oxidation from exhaust
• LPCB approved to EN 54-2, EN 54-4, EN 54-13 • Faster engineering with pre-configured devices and build-in • EN 54-27-approved detection for • Ideal for spaces where transitory false steam, cooking, cigarette smoke, gases, defective gas heating, cooking
• Fast and safe evacuation with voice sounders engineering tool air-handling ducts in conjunction alarm sources are expected aerosols, welding, etc. appliances or chemical and production-
with air sampling smoke detection • Application examples: kitchens, related processes
• Application examples: standard
FDBZ290 hotel and nursing home bedrooms workshops • Application examples: hotel garages,
2. Easy to use nursing homes, shared housing
• Auto-configuration (plug & play)
• License free engineering tool

You might also like