Floboss S600+ Flow Computer: S600+ Product Data Sheet
Floboss S600+ Flow Computer: S600+ Product Data Sheet
Floboss S600+ Flow Computer: S600+ Product Data Sheet
2 www.EmersonProcess.com/Remote
March 2016 S600+
www.EmersonProcess.com/Remote 3
S600+ March 2016
Liquid API CH 11.1 – 2004 / ASTM D 1250-04 / IP 200/04 and Addendum 1 2007
ASTM D 1250-1980 and API MPMS Chapter 11.1 – 1980 (Tables 5, 5A, 5B, 5D, 6, 6A, 6B, 6C,
6D, 23, 23A, 23B, 23D, 23E, 24, 24A, 24B, 24C, 24D, 24E, 53, 53A, 53B, 54, 54A, 54B, 54C,
54D, 59A, 59B, 60A, 60B)
ASTM/API 1952 (lookup tables for table 5, 6, 23 and 24)
ASTM/API 1952 (algorithm support for tables 23, 24, 53, and 54)
API 11.1, API 11.2.1, API 11.2.1M, API 11.2.2, API 11.2.2M, API 11.2.4
API 12.2.1, API 12.2.2, API 12.2.3, API 2540
API 21.2
ASTM D1555 & D1555M
GPA TP15, GPA TP16, GPA TP25, GPA TP27
Propylene API 11.3.2.2
Ethylene IUPAC, NIST 1045 & API 11.3.2.1
ISO 91/1 (IP2), ISO 91/2 (IP3)
STO 5.9 08 B1, B2, B3
NORSOK I-105 Annex D (water in oil)
Steam & Water IAPWS-IF97/2007 – regions 1, 2, 4, & 5; IFC-67 – regions 1 & 2
Downer 1979 calculation of CPL
ISO 17089-1 Annex E (Daniel ultrasonic meters, correction of meter geometry)
NPD
Densitometer algorithms Solartron/Micro Motion, Sarasota/PEEK
Prover Compact, uni-directional, bi-directional, master meter, dual chronometry
Support for NORSOK statistical evaluation of repeatability
Support for 1, 2, or 4 sphere switches
Each S600+ can support up to two provers (not simultaneously)
Note: Master meter (MM) proving support for MM volume vs Stream volume, MM mass vs
Stream mass, and MM volume vs Stream mass.
Communications
Configuration Port (located on Connector 6-pin RJ12
the bottom of the front panel) Communication RS232D
Standard
Signals Supplied Tx, Rx, CTS, GND
Baud Rate 2400, 4800, 9600, 19200, 38400, 57600
Format Config600 Protocol
Ethernet Speed 10 or 100 Mb/s, full Duplex
(NTWK1, NTWK2)
Media Connectivity 10 or 100baseT, twisted pair utilising standard RJ45
Protocol Modbus/TCP or Modbus over Ethernet
Master, slave, and peer-to-peer
Support for gas chromatographs, ultrasonic (Daniel, Instromet,
Caldon, and Sick), and Coriolis (Micro Motion)
Network printers Can support multiple printers for separate reports, alarms, and events
4 www.EmersonProcess.com/Remote
March 2016 S600+
www.EmersonProcess.com/Remote 5
S600+ March 2016
6 www.EmersonProcess.com/Remote
March 2016 S600+
www.EmersonProcess.com/Remote 7
S600+ March 2016
The FloBoss S600+ is supplied with one I/O (P144) module and one Pulse Mezzanine (P148) module as standard. Two additional
module slots are available. Optional modules include the following:
I/O (P144) Module Provides the S600+ with additional analog and digital I/O
(1 standard, additional Analog Inputs Quantity 12
modules are optional)
Analog Outputs Quantity 4
Digital Inputs Quantity 16
Digital Outputs Quantity 12
Pulse Inputs – Flow Quantity 2 dual pulse or 4 single pulse
(requires Pulse
Mezzanine module)
Frequency Density Quantity 3
Inputs
PRT (RTD) Inputs Quantity 3
Pulse Outputs Quantity 5
Raw Pulse Output Quantity 1, raw pulse output for proving, 0 to 10 kHz
Pulse Mezzanine (P148) Provides S600+ with pulse input capability.
Module
Quantity 2 dual pulse or 4 single pulse
Note: The Pulse Mezzanine module is installed as a daughter board
on an I/O (P144) or Prover (P154) module and does not use an
additional module slot.
Prover (P154) Module Provides the S600+ with an interface to a prover
(optional) Prover Types Compact, uni-directional, bi-directional, master meter, dual
chronometry. Up to 4 sphere switch
Digital Inputs Quantity 32
Digital Outputs Quantity 12
Pulse Inputs – Flow Quantity 2 dual pulse or 4 single pulse
(requires Pulse
Mezzanine module)
Frequency Density Quantity 2
Inputs
Pulse Outputs Quantity 4
Raw Pulse Input Quantity 3
Phase Loop Lock Quantity 1
Input
Switch Detect Quantity 4
HART (P188) Module Provides the S600+ with an interface to HART transmitters
(optional)
Quantity 12 channels. Each channel can be configured for point-point or multi-
drop communications. In multi-drop mode, each channel can support
up to 8 transmitters.
Modes Supports dual master (primary or secondary), read only (can not be
used to change constants on the HART device). Does not support
burst mode.
Max. Number of 50
HART Transmitters
Note: Contact technical support to obtain a list of HART devices tested with the S600+.
Power
Supply Voltage 20 to 32 Vdc, 30 Vdc nominal, 48 W maximum
Typical 18 W with 1 I/O module
8 www.EmersonProcess.com/Remote
March 2016 S600+
www.EmersonProcess.com/Remote 9
S600+ March 2016
Approvals
Approval Standards EMC Directive 2004/108/EC
TR CU 004/2011, TR CU 020/2011
Certified by “Technoneftegaz”
TC RU C-US.HO03.B.00304 valid from 30.06.2015 to 29.06.2020