Professional Documents
Culture Documents
Unit-1: Auditorium: College of Architecture, Nashik 422002
Unit-1: Auditorium: College of Architecture, Nashik 422002
Unit-1: Auditorium: College of Architecture, Nashik 422002
UNIT-1: AUDITORIUM
DESIGNPROBLEM
ACENTERFORPERFORMINGARTSATGANGAPURROADNASHIK
They decided to design and construct A Center for performing arts which will also be
developed as a Cultural center of the City. It will be a center for all the performing arts
likeDance and drama. It will be a multi-functional buildings on a site, with complexities related
toadvanced services like HVAC, Fire-fighting, Acoustics & Structural design with respect to
siteplanningandintegrationofcomplexrelationshipbetweentheform,functionandcontext.
Designerhastounderstandandconsidervariousissuesandaspectslikesustainability,Earthquakepro
ofconstruction,Renewableenergy,emergency/disastermanagementetc.andtheintegrationofthe
seaspectsinarchitecturaldesign.
Design programme:
Description B/UAreainSq.mts.
A. AdministrativeOffice
1.Managerroom+Att.Toilet: 15.0
2.Ticketroom: 12.0
3.Entrancelobby: 100.0
4.Adminstaff: 20.0
5.Toilets(Male&Female): 10.0
B. Serviceareas:Locationonly.
1. AHURoom: 10.0
2. Generator 10.0
3. Storeroom 15.0
4. Transformer 20.0
5. Electricroom 10.0
C. Stagearea
1. Stage: 80.0
2. Greenrooms-(2NoswithAttachedToilets): 20.0
3. Rehearsalrooms:2Nos. 70.0
4. Backstagearea.: 100.0
5. Orchestrapit: 30.0
6. Light&Soundroom: 30.0
7. Projectorroom: 20.0
D. Auditorium
1. Groundlevel:500seatscapacity 600.0
2. Balcony:100Seats 150.0
3. Cryroom: 15.0
4. Pre-functionlobby 100.0
E. Canteen,Kitchen&pantry: 70.0
F. Publictoilets
a. Commonwashroomsatsuitablelocation: 30.0
Ladies:3WC,3WashhandbasinsGents:3W
Cs,10Urinals,3Washbasins
b. Housingkeepingandmaintenanceroom: 10.0
G. Parkingrequirement:
Cars: 50Nos.
2wheelers: 200Nos.
Servicevehicle: 2Nos.
H. Circulationspaces,stairways,ramps,Liftsetc.asperdesign.
Drawingrequirements-
Stage-1
1. Conceptualsketches
2. Zoningandsinglelinesiteplan-Suitablescale
3. Singlelinefloorplanswith1schematicsection
Stage-2
Finaldrawingrequirements:
1. Siteplanwithbuildingblockandlandscapedetails,Parking,Internalroads-1:200
2. Site section (1 No.)- 1:200
3. Detaileddrawings-AllfloorplansincludingBalconylevelplan: 1:100
4. FrontElevationwith Curtain wall- 1:100
5. Sections-Min.2- 1:100
6. Proportionate3DView- Anysuitablescale
7. Servicesplans/Layouts
forHVACLayout,
Firefighting Layout,
Electrical/Lighting Layout,
Plumbing & Sanitary Layout
8. Constructiondetails
Structuralframing,
Balcony-
Structuraldetails,(Fulcrum&Rakerbeamdetails)Acousticdetails
False ceiling details
Related advanced details
Roofing details
SITE:100.0X125.0Mts.(Withshortestsidefacing18.0mtsroadonEastside)
Setbacks:
6mts.Groundcoverage:Notmorethan1/3plot. FSI-1
SITEPLAN
100.
0
6M Mts
125.0M 6M 6M
PROPOSEDSITE
9M
18.0MWIDEROAD