J7-c USB Tester English Manual (SZB)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

USB Energy Tester

- Usage introduction -
Range of application:
USB
INPUT

charge Mobile
r load phone
Micro USB
table
Adjus
INPUT

1: Notebook 5.15V 2.18 A


DISPLAY

Car ch insert RESET


insert
arger Type-C Type-C
INPUT 0085.27W/32C 000.03Ah OUTPUT

 0000.38Wh 000:05:56T


 USB DIGITAL TESTER

  1A
/1 0W 5
R e s is to rs
Desktop Mobile Power Pack USB lo a d
OUTPUT

USB power etc USB Equipment etc


USB Teset
Type-C
OUTPUT
RESET
DISPLAY

USB DIGITAL TESTER


0085.27W/32C 000.03Ah
0000.38Wh 000:05:56T
5.15V 2.18 A

insert
2: insert
INPUT
USB

USB
OUTPUT
Micro USB

Mobile
INPUT

phone
INPUT
Type-C

USB power supoly The tested data line


USB Teset
According to the above drawing 2 complete the connection , under the condition of constant
power supply and load, change different data cable, current displayed on USB tester is larger,
quality of data cable is better, and the charge speed is faster.
Tips:
When the ambient temperature changes or the outside heat conduction to tester
causes the current to not return to zero and the display shows 0.01A or 0.02A or
otherwise,Please Hold on the key buttion then insert to USB Charger It can make
the current temperature of the ambient current zero calibration,After the zero can
more accurate measurements.And when in Zero calibration,the output can not have
any load current consumption, so usb tester display 0.00A
Operation introduction:
(1)Long press in the main interface means that electricity, time all are reset and
cleared to zero (Wh、00:00:00)
(2)Double click means that power is reset and cleared to zero (Wh)
(3)Triple click means that time is reset and cleared to zero (00:00:00)
(4) without holding down the key not to put into electricity, electricity is the current
temperature environment current zero calibration(at the ambient temperature
changes or external thermal conductivity to U table lead to current is not zero, zero
calibration by this method,Zero calibration, the output shall not have any load
current consumption, so as to avoid mistakes zero)
(5) if the enter background mode, short press the switch calibration interface,
double-click the calibration starts
Specification:
Voltage measuring range: 3.60V ~ 32.5 V Resolution precision: 0.01 V
Current measuring range: 0.00 ~ 5.00 A Resolution precision: 0.01 A
Power cumulative range: 0 ~ 999999 MWH Resolution precision: 0.001 Wh
Power metering range: 0 ~ 299.999 W Resolution precision: 0.001 W
Timing maximum time: 999 H 59 M 59 S Resolution precision: 1 S
Time to refresh: > 500 ms/time > 500 ms/times
Measurement rate: 0.5 times/s Working temperature: - 10 ~ + 60 ℃
Product size: 65 x 24 x 14 mm Working humidity: 10 ~ 80 (no doubt)
Since the power flow: < 0.015 A The pressure of work: 80 ~ 106 kpa