NanoBOX - COMPRESSOR DATASHET - V 1.01


Customer Data Instrumentation
Company Base Parameters Nm3/h at 1.01 bara, 37.78ºC
Elevation 15.2 m
Unit Data Ambient Temperature 37.78ºC
Model 45‐5‐1800‐4 Suction Temperature 26.6ºC
Gas Specific Gravity 0,65

Performance Data
MINIMUM IN.PRESSURE WORKING PRESSURE MAXIMUM IN.PRESSURE
Suction Pressure 2,0 bar 3,5 bar 4,0 bar
Discharge Pressure 250,0 bar 250,0 bar 250,0 bar
Flow 142 Nm3/h 215 Nm3/h 239 Nm3/h
Power 31 kw 41 kw 44 kw
Specific Consumption 0,218 kwh/Nm3 0,190 kwh/Nm3 0,184 kwh/Nm3
COMPRESSION STAGES
1 1 2 3 4 5
Cylinder Gamma 4 LP (A) Gamma 4 LP (B) Gamma 3 LP Gamma 2 LP Gamma 1 LP Gamma 1 LP
Bore In (mm) 95 95 66 44 32 24
Inlet Pressure bar 4 4 18,1 39,9 68,0 123,7
Outlet  Pressure bar 18 18 40,3 68,7 124,8 254,5
Inlet Temperature ºC 27 27 48 48 48 48
Outlet Temperature ºC 151 151 114 96 107 111
Power kw 7,4 7,4 7,5 5,0 5,8 6,2

Pressure Alarms
PSL 1,8          
Inlet Pressure
PSH 4,4          
PSL 14,8 14,8 32,3 54,9 99,8 203,6
Outlet  Pressure
PSH 20,3 20,3 44,4 75,5 137,3 280,0
Safety Relief Valves PSV 26 26 60 140 300 300

Temperature Alarms
TSL            
Outlet Temperature
TSH 185 185 185 185 185 185

Graphics

Performance Curves
300 50

45

250
40

35
200

30

150 25

20

100
15
Flow (Nm3/h)

Power (Kw)

10
50

0 0
2,00 2,33 2,67 3,00 3,33 3,67 4,00
Inlet Pressure (bar)

Flow (Nm3/h) Power (Kw)

*All values may have a +/‐10% variation
**The manufacturer reserves the right to modify totally or partially any of the datasheet indications without any previous notification
***The power and specific consumption are at the compressor axis and do not consider losses for engine performance and equipment auxiliary systems
****The interstages pressures and performance may change depending on the different gas compositions.
*****The alarm values indicated are presented only as a reference and the Galileo's authorized technical service reserves the right of increasing or reducing them 
for the equipment performance optimization.