Field test form

7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

RELAY DETAILS

RELAY FUNCTION MOTOR PROTECTION AUX SUPPLY VOLTAGE 120 V

RELAY MAKE Siemens NOMINAL CURRENT 5A


ACTIVATED
TYPE / STYLE 7SK80
FUNCTIONS
S. NO.
Note:

1- Relay test were done as found activated protection functions.


2- Relay setting were left as found in the end of all testing (set as found before testing).

SECTION 1: GENERAL INSPECTION:

DESCRIPTION STATUS NOTE


Preliminary general examination, prior to energizing

Energizing

Parameter and protection settings

Logic input /output connections

Verify type/connections as per drawings.

Temperature sensor input connection to the relay (if applicable)

Actual trip test conducted (By perform trip test to the C.B coil).

Relay setting Was left as found

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
1
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

SECTION 2: PRIMARY SETTINGS RECORD:

General Description Setting


Motor full load
Network frequency
CT rating (Primary)
Characteristics CT rating (Secondary): 1A or 5A
Residual CT or Ground fault CT ratio
CT connections
VT connection
Rated primary voltage
Rated secondary voltage
Residual voltage (if applicable)

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
2
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

SECTION 3: METERING TEST:

Checking the relay Accuracy for the metering function


Current Expected current Measured current Measured current Measured current Tolerance
injection reading Phase A (A) Phase B (A) Phase C (A) ±5%
1.25
2.5
3.75

ground Current injection (A) Expected reading(A) Measured ground current (A) Tolerance ±5%
2.5
5

Checking the relay Accuracy for the metering function


voltage Expected voltage Measured voltage Measured voltage Measured voltage Tolerance
injection reading Phase A (v) Phase B (v) Phase C (V) ±5%
120

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
3
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

SECTION 4: PROTECTION TESTS

A- Current elements
Setting and Testing Points
t
Function I Picku I
Phase curve Td (expected t measured acceptance
adjusted p injected
)

A
Over
50 B
current
C
Earth 51 N N
fault 50 N N
Dir EF 67 N
Negative
46 ABC
sequence

Setting and Testing Points


Function (General)
Injected Expected Measured
Phase Set Value Curve Acceptance
current time time

Thermal over
49 ABC
load

B: Voltage Elements
Function Phase Setting and Testing Points

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
4
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

U adjusted u applied T adjusted t measured error ± 5% Acceptance

A
Under voltage 27 B
C
A
Over voltage 59 B
C
A
Negative sequence 47 B
C

Setting and Testing Points


Function Phase
F adjusted f applied T adjusted t measured error ± 5% acceptance
A
81L B
Under \Over C
Frequency A
81H B
C

Setting and Testing Points


Function Phase error ±
pickup i applied Adj time Measured time acceptance
5%

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
5
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

Mechanical jam ABC


Acceleration ABC ------

Setting and Testing Points


Function
Period of time adjusted Period of time applied Number of starts adjusted relay Start Blok function

Motor Restart
Inhibit 66
\

Voltage Phase reversal test


Injected value Expected result Observed result Remark

Va=120v , < 0

Vb= 0 v , < 0 NOT TRIP

Vc=120v , < 60

Va=120v , < 60
TRIP
Vb=0 v , < 0

Vc=120v , < 0

(49T) RTD accuracy testing RTD Type = ……..

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
6
Field test form
7SK80 Relay

CUSTOMER: PROJECT:
EQUIPMENT TAG NO.: DESCRIPTION: MOTOR RELAY
Drawing No: PLANT NO. / LOCATION:
TEST COMPLETION DATE:

RTD Under Applied Expected Temp Actual Temp


Alarm Level Trip Level
Test Resistance Reading Reading Note
ºC ºC
Ω ºC ºC
RTD1
RTD2
RTD3
RTD4
RTD5
RTD6

Relay Healthy status Please Tick √

After performing the test, the Relay Yes No Comment


was found in Healthy condition

SECTION 5: TEST EQUIPMENTS LISTING AND CALIBRATION DATA

DEVICE MAKE CALIBRATION DATE CALIBRATION EXP.


Relay Test Unit

RTD Unit

EEIC SHARQ PMD SHARQ AED


Name
Signature
Date
# Uncontrolled Form, Customer Requirement.
7