Versus Fluid Coupling 2
Versus Fluid Coupling 2
Model KRG
Coupling Connection / Direct Couple
Model KSD
Pulley Connection
MEDAN : JL. Cemara No. 53 Brayan Darat II ( 061 ) 8880 8888 FAX. 8880 8765 : sales@versusnetwork.co.id
PONTIANAK : JL. Adi Sucipto KM 10 Pondok Kita No. 7 ( 0561 ) 6726679 : pontianak@versusnetwork.co.id
WEIGHT SHEAVE
WEIGHT
OUT
SHEAVE OIL
T SHEAVE NO
SIZE Q S (WITH MAX. U V
MAX (WITH GROVE PITCH DIA
OUT OIL) LTD
OUT SECTION
KG
OIL) KG
5 SPB-5 B 112 10 15
M16 M10 M12
11 KSD 69 15 16~22 2.75 4 SPB-5 B •125 160 15.34
19
M20 M16 3 SPB-5 B •200 58
M16 M12 5 SPB-5 B 40 12
19
12 KSD 80 19 23~27 4.1 4 SPB-4 B •180 50
M20 M16
3 SPC-4 B •200 51 25.5
M16 8 SPB-8 B 140 12
13 KSD M27 88 31 37.6~45.5 5.2 19
M20 6 SPB-6 B •180 •250 50
15 KSD M27 M20 102 46 55.7~67.5 7.65 8 SPB-8 B 160 •200 •280 12 19
17 KSD M27 M20 132 74 97.5~99 11.7 10 SPB-10 B •224 •280 31 19
19 KSD M27 M20 132 82 107~108 14.2 10 SPB-10 B •224 •280 31 19
M20 M24 12 for D=80~90
21 KSD M36 145 110 146.5 19 12 SPB- 12B •250 •315 90
M24 52 for D=100
ACCESSORY FOR OVERLOAD PROTECTION
FUSIBLE PLUG
In overload conditions, when the slip reaches high value, the oil temperature rises damaging the seals and causing
the oil leakges. In order to avoid damages, in critical applications. It is advisable to fit a fusible plug.
FILLING INSTRUCTIONS
Fluid couplings are supplied without oil. It is essential to follow proper oil filling procedure.
1. With the fluid coupling mounted in a horizontal position, turn the coupling until the “X” mark is in vertical
position, which will ensure the filter/level plug is in the correct angular position as shown in Figure 6.
2. Fill oil until it overflows throught filter hole. During fillings, rock the coupling on its axis to ensure venting
of air from the circuit. Table A shows oil quantities for these fillings. The procedure for intermediate fills is
the same as above. Please ensure thar chosen number is at the top of the unit.
3. Use thread sealant on filter plug thread to avoid leakge during operation.
4. To obtain sealant on filter plug thread to avoid leakge during operation.
5. Fot application with ambient temperature up to -10˚C. Oil SAE 10W must be used (see below recommended
oils) at lower temperature use SAE 5W oil.
6. Also for vertical mounted applications, recommended oil fills are indicated in Table A.
RECOMMENDED
SAE 10W
OIL
AGIP OSO 32
ARAL VITAM GF 32
BP ENERGOL HLP 32
CASTROL HYSPIN AWS 32
CHEVRON HYDRAULIC OIL EP 32
ESSO NUTO H 32
MOBILE DTE (OIL LIGHT 24)
SHELL TELLUS 32
TEXACO RANDO HD 32 TABLE-A
TOTAL AZOLLA ZS 32
FIGURE-6