THE INSTITUTE OF PETROLEUM

PETROLEUM MEASUREMENT MANUAL

PART XV
Metering Systems

SECTION 2

GUIDE TO GAS METERING SYSTEMS


THE INSTITUTE OF PETROLEUM

PETROLEUM MEASUREMENT MANUAL

PART XV
Metering Systems

SECTION 2

GUIDE TO GAS METERING SYSTEMS

March 2002

Published by
The Institute of Petroleum, London
A charitable company limited by guarantee
Copyright © 2002 by The Institute of Petroleum, London:
A charitable company limited by guarantee. Registered No. 135273, England

All rights reserved

No part of this book may be reproduced by any means, or transmitted or translated into
a machine language without the written permission of the publisher.

ISBN 0 85293 360 6

Published by The Institute of Petroleum

Further copies can be obtained from Portland Press Ltd. Commerce Way,
Whitehall Industrial Estate, Colchester CO2 8HP, UK. Tel: +44 (0) 1206 796 351
email: sales@portlandpress.com
CONTENTS

Page

Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

1 Definitions and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


1.1 Quantitative and qualitative measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Flow measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Uncertainty and accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Applications - General requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5


2.1 Basic design considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Gas acceptability criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Performance and calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Choice of primary device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.5 Mass, volume and density measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.6 Service considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3 System design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 Design criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Piping configurations and valving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3 Secondary instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.4 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

4 Orifice meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 General principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2 Flow equations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.3 Meter design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

v
Contents Cont... Page

5 Other meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 Turbine meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2 Displacement meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.3 Vortex meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.4 Ultrasonic meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.5 Sonic nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.6 Some other meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

6 Calibration and proving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27


6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.2 Off-site calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.3 In-service proving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.4 Tracer methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

7 Secondary instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.1 Differential pressure transmitters (DPTs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.2 Temperature measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.3 Pressure measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.4 Density measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.5 Continuous measurement of density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.6 The pTZ method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.7 Measurement of relative density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.8 Installation of line density transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.9 Redundancy in density measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

8 Equipment for composition and quality measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39


8.1 Gas sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.2 Measurement of composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
8.3 Measurement of calorific value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.4 Measurement of Wobbe index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8.5 Measurement of hydrocarbon dewpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8.6 Measurement of water dewpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.7 Measurement of contaminants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

9 Flow computation and display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47


9.1 Flow computers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
9.2 Calculation of gas quantities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.3 Calculation of gas properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
9.4 Simple flow computers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

10 Commissioning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55


10.1 Testing and commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
10.2 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
10.3 Inspection and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Table 1- Main features of primary devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57


Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Annexes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

vi
FOREWORD
Measurement accuracy is essential in the sale, purchase and handling of petroleum products. It avoids disputes
between buyer and seller and provides control over losses. Accurate measurement involves the use of standard
equipment and procedures.

The Petroleum Measurement Committee of the Institute of Petroleum is responsible for the production and
maintenance of standards and guides covering the various aspects of static and dynamic measurement of petroleum.
These are issued as separate Parts and Sections of the Institute’s Petroleum Measurement Manual, which was first
published in 1952.

Membership of the IP working panels includes experts from the oil industry, equipment manufacturers, cargo
surveyors and government authorities. Liaison is maintained where appropriate with parallel working groups of the
Committee on Petroleum Measurement of the American Petroleum Institute, and is extended as necessary to
embrace other organizations concerned with quantitative measurement in other countries and in other industries.

Users are invited to send comments, suggestions, or details of experience with this issue to:

The Technical Manager, Standards


Institute of Petroleum
61 New Cavendish Street
London W1G 7AR
United Kingdom

The Petroleum Measurement Manual is widely used by the petroleum industry and has received recognition in
many countries by consumers and the authorities. In order to promote their wide adoption internationally, it is the
policy to submit selected standards through the British Standards Institution to Technical Committee 28 - Petroleum
Products and Lubricants - of the International Organization for Standardization (ISO) as potential International
Standards.

A full list of Parts and Sections of the Petroleum Measurement Manual (PMM) is available on request from the
Institute of Petroleum.

Note:

The IP Petroleum Measurement Manual is recommended for general adoption but must be read and interpreted in
conjunction with weights and measures, safety and other regulations in force in a particular country in which it is
to be applied. Such regulatory requirements shall have precedence over corresponding clauses in the Manual. The
Institute disclaims responsibility for any personal injury, or loss or damage to property howsoever caused, arising
from the use or abuse of any Part or Section of the Manual.

Attention is also drawn to the fact that some of the equipment mentioned in the Manual is protected by patents
throughout the world. The mention of any proprietary information in this Guide does not imply its endorsement by
the IP for any particular application; neither does omission imply rejection.

vii
ACKNOWLEDGEMENTS
The following members of the IP Petroleum Measurement Committee and of its Sub-Committees and Panels have
been associated with the production of the revision of this section of the Petroleum Measurement Manual:

M D H Bayliss Measurement Innovation Ltd.


J H R Phipps Institute of Petroleum (Editorial)

viii
INTRODUCTION
This section of the Petroleum Measurement Manual covers the specification, design, installation and operation of
metering stations for high accuracy measurement of the bulk flow of gases in pipelines and process plants. It was
first published in 1991, this revision being updated to incorporate new technology and latest standards.

The types of metering equipment described are intended for the measurement of natural hydrocarbon gases for the
purposes of sales, custody transfer, taxation or the allocation of production in a multi-user pipeline. Such systems
will be referred to in this guide as fiscal metering systems, implying a standard of accuracy that is the highest
reasonably attainable in practice, bearing in mind the balance between cost and accuracy.

Compliance with this guide and the relevant standards to which it refers should assist approval, where appropriate,
by the UK Government and other regulatory authorities but it does not guarantee or imply such approval.

It is hoped that this guide will also be of use in the design and specification of metering systems that are not required
to meet fiscal standards of accuracy such as those used for plant operational purposes, equipment performance
monitoring, etc.

Gas metering technology, at the time of revision of this guide, is at a state where the orifice meter is still in wide
use for fiscal gas measurement. There is a large amount of data in the form of internationally accepted standards
on the performance and construction of this type of meter. Other meter types are also in operation for fiscal
measurement that can offer a similar standard of accuracy, or that have specific advantages suitable for particular
purposes. In particular, multi-path ultrasonic meters are rapidly gaining acceptance as high accuracy devices.

Whilst this guide deals with the orifice meter in greater detail than other types of meter, this does not imply that
other types of meter, such as the turbine meter, ultrasonic or vortex meter, etc., are less suitable. The choice of meter
for each metering application should be made on the basis of suitability for purpose, taking account of the
performance of the meters offered by individual manufacturers and the developments that are continuing in
measurement technology.

It must be emphasized that this guide is not intended to replace any of the national or international standards
covering the detailed aspects of meter installation and design. The guide instead gives an overall picture of the
metering system and an introduction to its component parts with references to the appropriate standards, from which
further details can be obtained.