Electrical Test Instruments: PAT400 Series

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

Electrical Test Instruments

PAT400 series downloading portable


appliance tester
With memory for 10,000 assets and capability of uploading asset, test and location
you can be assured that you are working with the most productive PAT tester on the
market.

TPT series and MPU690 two pole testers


and proving unit
A really tough combination that could save your life, bring Megger build quality and
performance to safety checking.

Innovative
installation
AVO410 multimeter testers for your
A delightful new tester from the inventors of multimeters, offering true rms local standards
measurement and CAT IV safety.
The choice
of European
professional
testers MFT1800
series
Extra fast
portable
appliance tester
PAT400 series
True RMS
multimeter
AVO410

The word ‘Megger’ is a registered trademark


Multifunction testers RCD testing ranges MFT
Multifunction
n Type AC, A, S and B, programmable and 3-phase RCDs Features testers
dependant on model
MFT1800 series n Range of RCD tests available ½ x IDN, 1 x IDN, 2 x IDN and 5 x
IDN dependant on model
MFT
with
Electrician’s
certification
n Automatic polarity monitoring, changes input polarity and insulation
starts test tester
The MFT1800 series is tough n Auto RCD on MFT1825 and MFT1835 Electrical
n Fast RCD ramp test to measure RCD trip current with fast ramp test kits
It won’t go bang if it’s connected across phases, when it’s option Industrial
dropped, when it’s used in the rain, when the wrong range is insulation
Loop testing ranges Part P
testers
selected or when it’s connected to live circuits – even with the kits
n Automatic polarity monitoring, changes input polarity and
test button locked on! Combined
starts test
loop and
Dust and rain proof to IP54 the MFT1800 series offers CAT IV n 2-wire and 3-wire non-trip 0.01Ω L-PE High voltage
Usefully the MFT1800 series has Colour-coded selection knobs Large brightly backlit display Carry case has extra space so you RCD testers
safety meaning you can use it in any environment with out a n L-PE 48 V to 280 V, 45 Hz to 65Hz insulation
test buttons at both ends of the make sure you are in full control shows 2 parameters at a time can store tools as well as test testers
second thought. It can test to any IEC 60364 derived standard n Won’t trip 6 A MCBs tester, so there is always one to of testing. like insulation resistance and leads, and even a certificate pad.
quickly, easily and safely. The tester is supplied in a tough carry n PFC measurement at same time as loop resistance hand. applied test voltage
case ready to work, complete with batteries, user guides and n High current loop testing L–L and L-N
Low
n L-L 48 V to 480 V, 45 Hz to 65Hz resistance
calibration certificate.
n Auto-start loop test testers
With a good selection of earth tests, 15 mA auto-reversing
MFT series
Continuity and resistance testing range MFT1815 MFT1825 MFT835
continuity testing, and Type B and 2 x IDN RCD testing, and
n 200 mA test with an option of 15 mA on MFT1825 and MFT1835 Insulation test ranges 1000 V n n n
automatic reverse polarity correction for live tests on-board the
MFT1800 series is perfect for the testing you do. n Auto-reverse continuity test, displays the highest result
n Auto-start continuity test


500 V
250 V
n
n
n
n
n
n
accessories Earth loop
tester
100 V n
n Easy test lead null – stored even when switched off
Test voltage display n n n
n Fast buzzer with adjustable threshold on MFT1825 and
Adjustable buzzer threshold n n Earth
MFT1835
Continuity and 200 mA n n n resistance
n Resistance measurement from 0.01 Ω to 99.9 kΩ 0.01 Ω to 99.9 kΩ
resistance range 15 mA n n testers
Insulation testing ranges Easy lead null n n n
Auto-reverse continuity test n n n
n 1000 V, 500 V and 250 V with option of 100 V on MFT1835
Adjustable buzzer threshold n n n
n Test voltage displayed with insulation resistance measurement Electrical
Loop testing ranges 2 and 3-wire no-trip test L-PE n n n test kits
n Adjustable buzzer threshold
PSCC and PFC calculation displayed with
n 25 V or 50 V test inhibit option 1001-975
loop resistance n n n
n Voltage block protection against live circuits up to 600 V even 3-wire 10 A fused test lead set
L-PE 48 V to 280 V, 45 Hz to 65 Hz n n n
when test button is locked on
High current testing L-L and L-N n n n
L-L / L-N 48 V to 480 V, 45 Hz to 65 Hz n n Accessories
Earth tests
L-N 48 V to 280 V, 45 Hz to 65 Hz n n n
n Two-pole for use where 3-pole testing is not practical on
20 kA fault current n n n
MFT1825 and MFT1835
Touch voltage display 0 – 230 V n n n
n Three-pole earth electrode test on MFT1825 and MFT1835 Voltage
RCD Testing range 1 x IDN and fast ramp test n n n detector,
n Earth electrode testing using attached rod technique on
½ x IDN, 2 x IDN and 5 x IDN test n n Socket
MFT1835 tester
0º + 180º phase angle n n n
n Stakeless testing on MFT1835
30 mA, 100 mA, 300 mA, 500 mA RCD test n n n
Voltage, rotation and frequency test range 10 mA, 1000 mA RCD test n n
Auto RCD testing n n 1001-991 Clamp and
n 10 V – 600 V a.c. / d.c. Trms on MFT1835 3-wire lead test set
Fast ramp test n n n multimeters
n Phase rotation on MFT1825 and MFT1835
Type AC, A, S RCDs n n n
n Frequency measurement 15 Hz to 400 Hz
Type B RCDs n
n Touch voltage Programmable RCDs n n Solar and
3 phase RCDs n n earth
Communications on MFT1835 leakage
Voltage frequency and 6 V – 600 V a.c. and d.c. voltage n n n
n Bluetooth downloading testing
phase rotation range TRMS measurement n
n On-board memory sufficient Frequency 15 Hz – 400 Hz n n n
for 1000 records
Phase rotation n n
Earth testing 2-pole n n Appliance
Large bright dual testers
parameter display Requires optional 3-pole earth electrode n n
accessories Earth electrode using attached rod 1001-811
n Displays test voltage at the
technique n 3-wire earth electrode test set
same time as insulation
resistance Stakeless method n
Cable fault
25 V and 50 V output voltage n n
locator
Rechargeable Ground noise voltage check n n
Intelligent safety system Test lockout n n n
n Cells rechargeable in situ on Safe contact detector n n n
MFT1835
Live circuit warning n n n Network
Auto discharge n n n performance
Analogue arc display n n n
tester
Additional benefit Bright easy-to-read display n n n
Current measurement with optional clamp n n
Remote test probe n n Other
ICLAMP Megger
Rechargeable n 100 A current clamp products
FREE calibration certificate n n n
Warranty upgradeable to 3 years FREE n n n
Dust and weatherproof to IP54 n n n
Safety rating CAT IV 300 V CAT IV 300 V CAT IV 300 V About
Megger

4 MULTIFUNCTION TESTERS MULTIFUNCTION TESTERS 5


Insulation and continuity testers
MFT
Multifunction
Features testers

MFT
MIT300 series with
Electrician’s
certification
insulation
tester
The new Megger insulation testers are like no other tester you have used Electrical
test kits
Industrial
The Megger insulation testers will take the bashing that Your safety is Megger’s number one concern insulation
Part P
testers
testers receive when they are on site These safety features look after you and the tester – kits
They are rubber armoured and have an integral solid lid to n Safety interlock to prevent unsafe connection of the test Combined
cover the display. leads loop and
High voltage
Handy neck strap for hands Clear range selector for poor Double hinge keeps screen Shutter to prevent hazardous RCD testers
The lid has a heavy-duty hinge that locks away underneath n Safe contact detector keeping you and your tester safe insulation
free operation light conditions free from scratches or swings lead combinations testers
when in use, making it easy to use and impossible to lose. during continuity testing if it’s accidentally connected to a under to snap out of sight
And you don’t need to pull out the test leads to shut the lid. live circuit
n Live voltage warning alerts the user to a circuit voltage over
Low
The Megger MIT insulation testers are easy to use and quick 25 V when insulation testing resistance
to learn n Safety lockouts – MIT300 MIT310 MIT320 MIT310A MIT330 testers
Analogue
There are no buried functions, so it is easy to use these new – Prevents continuity testing on live circuits Insulation testing 250 V n n n n n
insulation testers. – Prevents insulation testing when circuit voltage is 500 V n n n n n
The colour coding helps test selection, speeding up testing time greater than 50 V 1000 V n n n n Earth loop
and helping you identify faults fast. Test range 1000 MΩ 1000 MΩ 1000 MΩ 1000 MΩ 1000 MΩ tester
Hands free operation Insulation limit alarm 0.01 MΩ to 1000 MΩ n n
The quick start guide in the lid keeps all the basic information
MIT300 series insulation testers are well balanced to hang Continuity testing Continuity to 100 Ω n n n n n
at hand if you need it.
comfortably around your neck enabling hands free operation Continuity buzzer n n n n n Earth
when you need it. Lead null to 9 Ω n n n <1⁄2 Ω n resistance
Adjustable buzzer 1 to 100 Ω n n testers
The continuity test and buzzer start automatically when you
How it works connect to a circuit, saving you time.

Voltage measurement
Audible buzzer disable
Volts AC/DC
n n
600 V 600 V 600 V 600 V
Insulation tests can be started using a switched probe or the Resistance measurement 10 Ω to 1 MΩ range n n
test button on the front of the tester. Electrical
The best place for a test button is on the probe. 10 Ω to 2 KΩ range n test kits
By using a switched probe rather than a standard one Features Voltage warning n
Default voltmeter n n n n
there is no longer a need to look away from the probe
Backlit display n n
to find the TEST button on the instrument, or use a third
Backlit selector ranges n n
hand if both are already holding the probes. Simply press Accessories
Locking test button n n n n n
the button already under your finger. Auto power-down n n n n
Definitely safer and quicker. Switched test probe n n
Data storage n Voltage
Download via USB port n detector,
IP54 weatherproof n n n n n Socket
Accepts rechargeable batteries n n n n n tester
Included accessories 2 wire lead set n n n n n
Free calibration certificate n n n n
Warranty upgradeable to 3 years FREE n n n n n Clamp and
multimeters

MIT series accessories Solar and


earth
MIT320 comes with switched probe leakage
and calibration certificate testing

Special features
Appliance
testers

n Thick rubber armoured case 1002-491 1002-001


Red and black probes 2 wire test lead set
n Clear colour coded selectors and clips
Cable fault
locator
n Large, easy to read display
n Super grip test-leads with lock on
Network
croc clips performance
Tough lid prevents damage tester
n Tough to the display

n Easy to use
Other
n Safe 1002-015 1001-884 Megger
2-wire 500 mA fused Remote switched probe products
n Weatherproof test lead set with special plug
n USB downloading on MIT330
See page 8 and 9 for our industrial About
Megger
insulation testers

6 INSULATION TESTERS INSULATION TESTERS 7


Insulation and Insulation and continuity testers
MFT
Multifunction
testers

continuity testers for industrial maintenance and telecommunications MFT


with
Electrician’s
MIT200 series Continuity testing
n Automatic continuity testing is performed at 200 mA to
MIT400 series Continuity testing
n Auto test on contact enables real two handed operation
certification
insulation
tester
n A choice of 200 mA or 20 mA continuity test currents to increase Electrical
MIT220 and MIT230 are two of the ensure compliance with international requirements. No need
to press the test button
Insulation testing battery life test kits
smallest insulation testers available n All instruments will measure up to 100 Ω on continuity, of n 50 V to 1000 V insulation test voltages available with resistance n Lead null - up to 9 Ω of resistance Industrial
to 200 G Ω n Buzzer - ON-OFF selected by simple push button insulation
which 0-10 Ω is performed at greater than 200 mA to meet Part P
testers
Both products have a combination of digital readout and n Unique 10 V to 100 V variable voltage tester (MIT40X) n Buzzer limit adjustable from 1 Ω to 20 Ω in 5 steps
international electrical testing requirements kits
analogue display, using Megger’s patented DART display n Test lock - Locks insulation test on Combined
n Lead null is possible up to 9.99 Ω of test lead resistance, n Actual test voltage is displayed as well as insulation result on the loop and
technology. The display includes a clear, accurate digital read- High voltage
ensuring the ability to null fused test leads as well as larger display
out, and an analogue pointer response for evaluating circuit
charge and discharge characteristics.
standard leads n Analogue arc replicates the response of a moving coil display Special features RCD testers
insulation
testers
n Continuity buzzer n Polarisation Index (PI), Dielectric Absorption Ratio (DAR) and
The tough ABS instrument housing is designed to withstand timer functions
the rigours of hard use, whilst small enough to drop into your
n A continuity buzzer provides a means of rapid cable testing n CATIV 600 V
and circuit identification, with voltage protection should you n Silicone leads prevent errors on high G Ω ranges
Low
pocket when not in use. A low battery warning indicator gives n Test inhibit prevents insulation testing if voltages in excess n TRMS voltage measurement resistance
accidentally touch a live circuit
advanced warning of exhausted batteries. of 50 V or 75 V on telecoms testers. Live circuit detection and testers
n The buzzer operates at a 5 Ω threshold protection n PI, DAR and timer measurement
n Insulation buzzer - Preset the buzzer to an insulation resistance and timer modes
limit from the setup menu
Insulation testing n Remote switched probe Earth loop
tester
n There is a choice of two or three test voltage ranges
providing an ideal solution to most low voltage insulation Special features
testing applications MIT400 series accessories
n Insulation testing is possible up to 1000 MΩ on all ranges n Exceptional value for money Earth
resistance
n Auto discharge ensures all circuits are safely discharged after testers
n Pocket sized tester
testing
n 1000 V insulation test ranges have a high voltage warning n Live circuit protected
prior to test voltage being applied Electrical
test kits

1002-001 1001-878 Accessories


2 wire test lead set Switched CATIV 600 V probe

Voltage
MIT220 MIT230 detector,
Socket
250 V and 500 V test ranges to 1000 MΩ n tester
250 V, 500 V and 1000 V test ranges to 1000 MΩ n
Continuity (200 mA) measurement n n
Voltage detection n n Clamp and
Intelligent safety system n n multimeters
Fast buzzer range n n 1002-015 1002-491
2-wire 500 mA fused Red and black probes
Display backlight n n
test lead set and clips
CATIII 600 V n n Solar and
earth
IEC61010 n n
leakage
Warranty upgradeable to 3 years FREE n n testing

Industrial maintenance insulation Telecommunications insulation


and continuity testers and continuity testers
Appliance
MIT400 MIT410 MIT415 MIT420 MIT430 MIT40X MIT480 MIT481 MIT485 testers
250 V, 500 V and 1000 V insulation test n n n n n n

MIT200 series accessories


50 V and 100 V insulation test n n n n n n
10 V , 25 V, 250 V and 500 V insulation test n
Cable fault
10 V to 100 V in 1 V steps n locator
Resistance to 20 GΩ 100 GΩ 50 GΩ 200 GΩ 200 GΩ 20 GΩ 100 GΩ 200 GΩ 200 GΩ
Continuity 0.01 to 200 Ω n n n n n n n n n
Live circuit warning 50 V 50 V 50 V 50 V 50 V 50 V 75 V 75 V 75 V
Network
Polarization Index PI
n n n n n n
performance
Dielectric absorption rate DAR n n n n n n tester
Frequency measurement n n n n n n
Capacitance measurement n n n n
Distance by capacitance n n Other
Data storage n n n n Megger
1002-001 1002-015 products
Bluetooth downloading n n
2 wire test lead set 2-wire 500 mA fused Safety CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V CATIV 600 V
test lead set
FREE calibration certificate n n n n n n n n n
Warranty upgradeable to 3 years FREE n n n n n n n n n About
Megger

8 INSULATION AND CONTINUITY TESTERS INSULATION AND CONTINUITY TESTERS 9


High voltage insulation testers MIT525 and MIT1025 MFT
Multifunction
testers
Electrical engineers requiring more diagnostic functions on
their testers will find the additional sophistication of the NEW
NEW MIT515, MIT525, MIT1025 and S1 series MIT525 and MIT1025 meets their needs. Offering testing to
MFT
with
Electrician’s
5 kV and 10 kV respectively, these testers feature automatic certification
insulation
High voltage insulation testers that insulation resistance testing polarization index (PI), dielectric
absorption ratio (DAR), they add step voltage (SV)
tester
Electrical
have no equal. dielectric discharge (DD) and a ramp test. test kits
Since 1903 Megger branded instruments have been setting n Insulation test voltages from 50 V to 10 kV for maximum The 10 kV isolated USB interface makes Industrial
the standard for insulation testing. This selection of testers flexibility real time downloading of test data and insulation
Part P
testers
represents our best yet. Offering the user IEC61010-1 Category n Insulation resistance measurement up to 35 TΩ to help stored information to asset management
kits
IV 600 V safety, these testers are tough. So tough we have been predict insulation problems early software quick, easy and intuitive. Combined
able to rate them at IP65, meaning they are dust proof and n Guard terminal function available to eliminate surface All the MIT series of testers include lithium loop and
High voltage
immune to jets of water. Megger’s unique dual case design current effect ion battery technology reducing full RCD testers
insulation
means no compromises have to be made. They come in an easy n High charge current available for measurement of inductive recharge time to only 2.5 hours, while a testers
to carry outer plastic case that they can take the bashing that loads 30 minute recharge will give you an hour’s
you would expect when in use on site, while an inner case has 5 kV testing in to a 100 MΩ load.
n High noise immunity for measurement in areas of high
all the fire retardant properties you require. electrical noise Low
resistance
The whole range is relatively simple to use. A quick-start n Tough construction S1-568 and S1-1068 testers
guide is included in the lid of the tester, removing the need
to carry bulky user manual, and explaining all the controls in n Dual case design With a full 8 mA of noise rejection and 4 levels of filtering S1-
detail. Adjustable timers and limit alarms are built in. There is n Diagnostic functionality 568 and S1-1068 obtain meaningful results in extremely hostile
environments. Offering the full gamut of automatic insulation Earth loop
large, clear, back-lit display. Information shown on the screen n Quick rechargeable battery and a.c. operation tester
includes insulation resistance, the applied voltage, test current, tests, IR, timed IR, polarisation index (PI), dielectric absorption
n On-board test result storage ratio (DAR), Step Voltage, Dielectric Discharge and ramp, they
capacitance, battery status and time constant. The elapsed MIT515 can be used when
time is also displayed through out the test, so you know where allow the operator to control the test remotely from a computer plugged in to the mains, on
you are as the test proceeds. The display is back-lit to make it using the 10 kV isolated USB port, to store the date and time battery or while recharging. Earth
stamped results on board or to download them is real time using resistance
easy to read, whether you are working in bright sun light or a MIT515 testers
poorly lit area. The testers can be operated when plugged in to For customers who require a simple high voltage insulation Bluetooth. This is the perfect tester for the itinerant contractor as
an a.c. supply or on the battery power, meaning that you are tester the MIT515 is the perfect service and maintenance tool. it will give results in any electrical environment.
always in the position to get on with the job. Tough and testing to 5 kV, the MIT515 does not offer all the
Electrical
To ensure you are measuring what you think you are measuring testing flexibility of other instruments in the range but does test kits
and not surface leakage the Megger high voltage insulation offer popular test modes, basic and timed insulation resistance,
testers, like many 5 kV and 10 kV insulation testers available, polarization index and dielectric absorption ratio. With MIT515 MIT525 S1-568 MIT1025
S1-1068
are fitted with a guard terminal. However Megger actually safety features such as locking test leads, a test button that Test voltages 10.0 kV n n

specifies the performance of the guard terminal, so you can’t initiate a test by simply being knocked accidentally and 5.0 kV n n n n n
Accessories
operation to 3000 m with CATIV 600V protection a user’s safety 2.5 kV n n n n n
know it really is doing its job correctly. Remember the guard
is ensured. Megger testers have the merits of a stable voltage 1.0 kV n n n n n
terminal performance is an integral part of your measurement
500 V n n n n n
uncertainty. 10 kV testers are capable of measuring insulation supply and high specification guard terminal to ensure accurate
250 V n n n n n Voltage
resistance up to 35 TΩ and 5 kV testers up to 15 TΩ. This means results. detector,
Variable test voltages 10 V steps from 40 V to 1 kV n n
that you are able to spot deteriorating insulation early, trend 10 V steps from 100 V to 1 kV n n n
Socket
tester
its deterioration and predict when it will need replacement, 25 V steps from 1 kV to max
making for a truly planned approach to maintenance. test voltage n n n n n

MIT and S1 series Measurement



Max reading
Min reading
10 TΩ
10 kΩ
10 TΩ
10 kΩ
15 TΩ
10 kΩ
20 TΩ
10 kΩ
35 TΩ
10 kΩ Clamp and
multimeters
accessories

Voltage
Capacitance
n
n
n
n
n
n
n
n
n
n
Leakage current n n n n n
Test types Insulation resistance n n n n n Solar and
earth
Timed insulation resistance n n n n n
leakage
Polarisation index n n n n n testing
Dielectric absorption ratio n n n n n
Step voltage n n n n
Dielectric Discharge n n n n
Appliance
Ramp test n n n n testers
Other Features Analogue and digital display n n n n n
8101-181 1000-441 Timer control and display n n n n n
Compact clip test lead Medium clip test lead
Short circuit current 3 mA 3 mA 6 mA 3 mA 6 mA
set available in 3, 8 and set available in 3, 10 and
15 m length 15 m length Max noise rejection 3 mA 3 mA 8 mA 3 mA 8 mA Cable fault
Remote control via USB port n n locator
Interfaces USB output n n n n n
Bluetooth output n n
Power supply Mains n n n n n
Rapid rechargeable Li ion battery n n n n n
Network
performance
Weight kg 4.5 4.5 4.5 4.5 4.5 tester
Software supplied PowerDB lite n n n n
Safety CAT IV 600 V n n n n n
1000-443 Ingress protection IP65 IP65 IP65 IP65 IP65
Other
Large clip test lead set FREE calibration certificate supplied n n n n n Megger
available in 3, 10 and 15 m Warranty upgradeable to 2 years FREE n n n n n products
length

About
Megger

10 INSULATION TESTERS INSULATION TESTERS 11


Low resistance testers n Up to 10A test currents MFT
Multifunction
testers
n Protection against accidental connection to a live circuit

DLRO10 series n Automatic checks continuity of connections


n Multiple operating modes including fully automatic
MFT
with
Electrician’s
certification
insulation
n Option of high and low power testing
High voltage insulation testers that tester
n Fast charge battery option Electrical
have no equal. n Highly accurate continuity measurement
test kits
Low resistance testing, some times know as Ducter testing, Industrial
is a method of checking the continuity of a of a bond, cable insulation
Part P
testers
joint or busbar and confirming that there is as little energy loss DLRO10HD offers a choice of kits
DLRO10HD offers a different combination of features that
across the test piece due to resistance as possible. Applications high and low power testing Combined
may more closely meet your needs, housed in a tough poly
are extensive, from power engineering through to aeroplane loop and
propylene case, it is rated at IP54 when in use battery powered, High voltage
RCD testers
maintenance, and quality control to rail maintenance. insulation
and IP65 when the case is closed. It can be operated from both
DLRO10 is an entry level, low weight low resistance tester. It is testers
mains and battery and while re-charging.
fully automatic selecting the most suitable test current up to
Uniquely DLRO10HD also offers the ability to test at high or
10 A d.c. to measure resistance from 0.1 μΩ to 2000 Ω. It makes
low power. This gives the potential of condition diagnosis and Low
measurements with forward and reverse currents to cancel resistance
is particularly useful for measuring thick conductors, bonds and
the effects of any standing voltages across the test sample and testers
welding quality. DLRO10HD can output 10 A for 60 seconds in
displays the results on a large bright LED display. It is powered
to 250 mΩ
by a purpose built NiMH rechargeable battery pack which can
be swapped out while it is being recharged. The pack contains
Earth loop
its own battery state indicator. DLRO10 testers are used tester
extensively by London Underground for checking earth bonds
in the dirty, damp environment that the tunnels under the city Resolution DLRO10 DLRO10X DLRO10HD
offer. Ranges, 0.25 W power limited 0.1 μΩ 1.9999 mΩ 1.9999 mΩ 2.5000 mΩ
DLRO10 comes complete, even Earth
DRLO10X must be, pound for pound, the most sophisticated 1 μΩ 19.999 mΩ 19.999 mΩ 25.000 mΩ resistance
with a car charger
low resistance tester on the market. Offering the same low 10 μΩ 199.99 mΩ 199.99 mΩ 250.00 mΩ testers
weight and detachable, rechargeable batteries as the DLRO10, 100 μΩ 1.9999 Ω 1.9999 Ω 2.5000 Ω
10 mΩ 199.99 Ω 199.99 Ω 250.00 Ω
the DLRO10X has sufficient on-board memory for 700 sets of
100 mΩ 1999.9 Ω 1999.9 Ω 2500.0 Ω
results and notes. Notes are made using the alpha-numeric Electrical
Ranges, high power 10 μΩ 250.00 mΩ
keypad and can be downloaded to a computer. DLRO10X test kits
100 μΩ 2.5000 Ω
displays the forward and reverse readings and the average Measurement mode Manual n n
of the two on its LED screen with in 3 seconds. Amazingly Automatic n n n
the basic accuracy of the instrument is 0.2%. Among other Continuous n n n
applications one customer uses the DLRO10X for production Inductive mode 10A n Accessories
quality control, putting its facility for real-time data transfer to Inductive mode 1A n n
good use. Unidirectional n
Display LED 41/2 digit LCD backlit LCD backlit
Voltage
Results and data storage n detector,
Weight 2.6 kg 2.6 kg 6.7 kg Socket
Power supply Mains n tester
Rechargeable battery n n n
Battery charging time 4 hr 4 hr 8 hr
Ingress protection rating up to IP65 Clamp and
Safety CATIII 300 V n multimeters
Safety CATIII 600 V n n
Warranty upgradeable to 2 years FREE n n n
Solar and
earth
leakage
testing

DLRO accessories
Appliance
testers

Cable fault
locator

1000-809 6111-518 6111-022 Network


performance
Kelvin lead kit available in Duplex hand spike set Duplex hand spike with
tester
30, 50 and 100 m length 600 V rated sprung probe available
in 2.5, 6 and 9 m length

Other
1000-809 Megger
Kelvin lead kit available products
in 30, 50 and 100 m
length

About
Megger

12 LOW RESISTANCE TESTERS LOW RESISTANCE TESTERS 13


2-wire non-tripping loop testers High current loop tester
MFT
Multifunction
testers
Special features
LTW series Three-phase safe
The instruments will operate on a wide range of electrical
LT300 MFT
with
n High current loop testing Electrician’s
certification
2 wire testing voltages. insulation
The LT300 offers high current loop testing over a wide range n Wide range of frequencies tester
The loop test is performed with only 2 test leads. This can be High resolution test of frequencies and supply voltages with simple, fast, two wire Electrical
either:
LTW425 offers a high current, high resolution loop test to three
operation. n Wide range of supply voltages test kits
n Phase to Earth Industrial
decimal places (0.001 Ω). Frequency range n CATIV 300 V insulation
n Phase to Neutral Part P
testers
n Phase to Phase PFC Display Supply frequency is indicated upon connection and the LT300 kits
Testing is simple. There is no need for a third wire which could All instruments can calculate up to 20 kA and the LTW425 can will automatically set to the supply frequency either 16 Hz, Combined
33 Hz, 50/60 Hz, 125 Hz or 400 Hz. Testing will commence loop and
cause confusion in identifying the part of the circuit under test. calculate up to 40 kA using the 0.001 high current, resolution High voltage
RCD testers
test range. automatically. insulation
Non-trip loop testing testers
Loop measurement
LTW series testers are guaranteed not trip working RCDs of
30 mA, using the Non-trip loop test. Two loop impedance ranges are provided.
20 Ω - Resolution to 0.01 Ω Low
resistance
Noise detection on non-trip tests 200 Ω - Resolution to 0.1 Ω testers
LTW uses sophisticated noise detection circuitry which
continually monitors the supply during a loop test to ensure the Supply voltage
accuracy of the result has not been affected by electrical noise Operational supply range extends from 50 V to 550 V
Earth loop
from plant and services. (400 V @ 16 Hz), with a warning for voltages over 330 V tester
Two operational modes are available: highlighting accidental phase to phase connections on a
a) Performs a 10 second test and if noise is detected a warning nominal 230 V system.
is displayed. Earth
b) Automatically extends a test to improve the accuracy. LTW and LT series accessories resistance
testers
High current loop testing
For supplies that are not RCD protected the high current test
The popular LTW325 comes
can be used, as there is no risk of tripping the RCD. Electrical
complete, ready for work test kits
Auto start
An auto-start function will start the loop test running as soon
as the test leads are connected, means much faster testing.
Special features Accessories

1001-976 6220-832 1001-977 2-wire 10 A


n Uses only two wires to loop test 2 wire test lead set Euro mains test lead set fused test lead set Voltage
detector,
Will not to trip RCDs while loop
n  Socket
testing tester

n Will not take out 6 A MCBs LTW315 LTW325 LTW335 LTW425 LT300
Loop testing 2-wire non-tripping loop testing n n n n Clamp and
n Clear easy to read display 2-wire high current, fast, loop testing n n n n n multimeters
110 V to 280 V applications n n n n n
n 3-phase safe 50 V to 440 V applications n n n n
50 V to 550 V applications
n 50 V to 440 V operation n Solar and
Phase to phase testing n n n n earth
n PFC display PFC range 20 kA n n n n n leakage
PFC range 40 kA n testing
n Stable test results Resolution 0.01 ohm n n n n n
Resolution 0.001 ohm n
n USB downloading on LTW335 Automatic noise detection n n n n Appliance
Automatic test start n n n n n testers
Frequency measurement n n n n n
16 Hz to 400 Hz operation n
Max Zs display n n n
Max R1 + R2 display n n n Cable fault
locator
Features Back lit display n n n n
Built-in fold away cover n n n n n
Quick start guide in cover n n n n n
Test result storage n Network
Downloading of test results n performance
Accepts rechargeable batteries n n n n n tester
Included accessories Storage and carry case n n n n n
2-wire lead set complete with crock clips n n n n Optional
Mains socket lead set n n n n Optional Other
Free calibration certificate n n n n Megger
products
Standards IEC61010-1 CATIV 300 V n n n n n
EN61557 n n n n n
Weather- and dust-proof to IP54 n n n n n
Warranty upgradeable to 3 years FREE n n n n n About
Megger

14 LOOP TESTERS LOOP TESTERS 15


Earth resistance testers
MFT
The tough and easy-to-use DET4TD2 and its rechargeable Clamp-on earth electrode tester Multifunction
testers
counterpart the DET4TR2 are a popular choice with DET14C and DET24C
contractors. Capable of performing 2,3, and 4 pole
DET series measurements these instruments are ideal for testing both
ground electrode systems, and soil resistivity.
DET14C and DET24C induce a test current into earth systems
and measure earth resistance in multi earth installations
MFT
with
Electrician’s
without the need to disconnect the earth connection. certification
insulation
High resolution earth tester These earth clamps offer major advances in safety and tester
DET2/2 DET4TC2 and DET4 TCR2 access. A CAT IV 600 V rating combined with an automatic Electrical
The DET4TC2 and its rechargeable counterpart the test kits
n High resolution – 1 mΩ – ideal for large earthing systems current warning to reduce risk of user disconnecting
DET4TCR2 are advanced ground testers capable of electrode with a hazardous current flowing. The unique Industrial
n High accuracy for earth electrode and soil resistivity testing insulation
performing 2,3, and 4 pole measurements. these instruments elliptical head shape and short body length give unrivalled Part P
testers
n Test voltage 50 V max. for safety
may be further enhanced with the addition of an ICLAMP access to awkwardly sited electrodes. kits
n Rechargeable battery power with long battery life and and VCLAMP. The ICLAMP will allow the user to perform Combined
n Elliptical clamp shape with 39mm x 55mm inner jaw
rapid re-charge A.R.T. (Attached Rod Technique) measurements, removing dimensions loop and
High voltage
n A robust, versatile instrument with IP54 protection the need to disconnect an electrode from a system to test it. RCD testers
n Low maintenance flat jaw interface insulation
n Filter and high current features to enable valid earth testing Using both an ICLAMP and a VCLAMP will allow stake-less testers
n CAT IV 600V safety
in difficult situations measurements, perfect for locations where driving auxiliary n Automatic noise current warning safety feature
The DET2/2 Earth Tester is a reliable instrument designed stakes is not practical.
n Resistance and current ranges - auto ranging
Low
for larger or more complex earthing systems, including The addition of variable test frequency allows the user to n Automatic noise filter function resistance
communications earthing systems and difficult testing move away from problem noise frequencies, and extended 6320-245 testers
resistance ranges extending soil resistivity capabilities. Professional earth test kit
environments. It may be used to test in accordance with
BS 7430 (1991), the IEE Wiring Regulations and VDE 0413
part 7 (1982). The instrument is suitable for soil resistivity Three pole earth electrode tester DET2/2 DET4TCR2 DET4TC2 DET4TR2 DET4TD2 DET3TC DET3TD DET14C DET24C
Earth loop
Test techniques available
measurements. Resistivity tests assist the design of a correct DET3T tester
4 pole resistivity test n n n n n
earth system and avoid the risk of costly of re-work of
n 3-pole earth electrode testing and bond testing 3 pole electrode test n n n n n n n
electrode installations. 3 pole electrode test with ART
n Attached Rod Technique (ART) option n n n

n Selectable 25 V or 50 V output
2 pole bond test n n n n n n n Earth
Four pole soil resistivity tester Stakeless test n n n n resistance
DET4T n Complete with lead and stake kit Power Rechargeable n n n testers
n Simple one button operation Dry cells n n n n
n 2,3 and 4 pole testing selected by turning a switch
n Hardwearing carry case Warnings Excessive noise n n n n n n n
n Extended test range to 200 kΩ option Potential spike resistance high n n n n n n n
n Delivered with calibration certificate Electrical
n Dry cell or rechargeable versions Current spike resistance high n n n n n n n test kits
n IP54 rated
n User selectable test frequency and voltage option Resistance range 0.010 Ω – 0.01 Ω – 0.01 Ω – 0.01 Ω – 0.01 Ω – 0.01 Ω – 0.01 Ω – 0.05 Ω – 0.05 Ω –
1999 kΩ 200 kΩ 200 kΩ 20 kΩ 20 kΩ 2.0 kΩ 2.0 kΩ 1.5 kΩ 1.5 kΩ
n Attached Rod Technique (ART) option
DET3TD Resolution 0.001 Ω 0.01 Ω 0.01 Ω 0.01 Ω 0.01 Ω 0.01 Ω 0.01 Ω 0.01 Ω 0.01 Ω
n Stakeless measurements option
Earth current range
The DET3TD is a popular choice with contractors due to Accessories
n Automatic circuit checking 0.5 mA to 35 A n n
their toughness. Capable of performing 2 and 3 pole
n Comes with Power DB Lite earth testing forms that do the 0.5 mA to 19.9 A n n n
measurements these instruments are great for testing both
calculations for you Test frequency 105 Hz – 94, 105, 94, 105, 128 Hz 128 Hz 128 Hz 128 Hz 1390 Hz 1390 Hz
installation and lightning protection ground electrode 160 Hz 111 and 111 and 128 Hz 128 Hz 128 Hz 128 Hz 1390 Hz 1390 Hz
n Backlit display Voltage
systems. 128 Hz 128 Hz detector,
n Weather and dust proof to IP54 The instrument is tough in every way, built to work in the Socket
Noise rejection 40 V peak to peak n n n n n n n
n Safety rated CATIV 100V tester
roughest of outside conditions, and built to give the user Test results storage n n
n Complete with lead and stakes packed in a hard wearing a high level of electrical safety. This is demonstrated by Downloadable test results n
carry case specifications such as IP54 ingress protection, high noise IEC61010-1 safety rating CAT III CAT IV CAT IV 1 CAT IV CAT IV CAT IV CAT IV CAT IV CAT IV
300 V 100 V 100 V 100 V 100 V 100 V 100 V 600 V 600 V Clamp and
n Delivered with a FREE calibration certificate immunity, and CATIV safety. multimeters
Weather- and dust-proof to IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP30 IP30

DET3TC Warranty upgradeable to 3 years FREE n n n n n n n n


Power DB earth testing forms n n n n
The DET3TC, is like the DET3TD however, with the addition Solar and
of an ICLAMP adds the capability of performing A.R.T. earth
leakage
(Attached Rod Technique) measurements, removing the testing
need to disconnect a single electrode from a system to be
able to measure it.
Appliance
testers

Features
DET4 and DET3 series
Cable fault
accessories locator

Network
performance
tester

Other
Megger
products

1001-811 6220-803 DET14C flat jaw interface makes Elliptical jaw shape improves
3-wire earth lead test set 4 right angled adaptors for long service life access
About
Megger

16 EARTH RESISTANCE TESTERS EARTH RESISTANCE TESTERS 17


Electrical test kits Phase Sequence Indicator
MFT
Multifunction
In a scene reminiscent of a James Bond movie, an testers
aluminium flight case recently came flying from the

MTK PSI410
window of a speeding van on the M69 motorway. The case MFT
contained the latest in electrical testing technology, in the with
form of a Megger MTK320 electrical contractors’ test kit Electrician’s
certification
insulation
Megger MTK300 test kits give electrical contractors all they that had been stolen from a vehicle belonging to a leading Electrical work on commercial and industrial installations often tester
need to perform electrical inspection and testing for single and electrical training provider. requires working on motorised machinery with three phase Electrical
three phase operations. The kits consist of three instruments, supplies. Correct sequence of the phases is important with test kits
Despite a rough landing at speeds close to
an MIT insulation tester, an LTW earth loop tester and an certain motors and pumps as damage to brakes and valves will Industrial
70 mph, the three testers that make up the kit survived
RCDT residual current device tester, each with batteries fitted, occur in minutes with incorrect phasing. insulation
their ordeal completely unscathed. A thorough check in the Part P
in a smart case, with a full set of test leads and calibration testers
Megger calibration laboratory showed that none of the The Megger PSI410 phase rotation indicator provides rapid kits
certificates. Three kits are available: MTK310, MTK320 instruments needed even the slightest of adjustments. indication of correct phase sequence utilising a three bi- Combined
and MTK330. loop and
Now that’s what we call tough! coloured LED display and a specific audible tone. Clockwise High voltage
rotation is indicated by clockwise rotating green LEDs with a RCD testers
insulation
continuous tone and counter clockwise rotation has counter testers
clockwise rotating red LEDs and a warbling tone.
The unit has been designed to provide a slow rotational speed Low
MTK310 MTK320 MTK330 of the display to allow easy recognition of the direction of resistance
Insulation testing (see pages 10 and 11 for technical data) MIT310 n rotation. testers
MIT320 n
Dual phase colour coding has been adopted for the PSI410 to
MIT330 n
allow ease of use on both Brown / Black / Grey and Red / Yellow
Loop testing (see pages 12 and 13 for technical data) LTW315 n Earth loop
/ Blue colour coded supplies.
LTW325 n tester
LTW335 n The PSI410 also features a triple bi-coloured LED display
RCD testing (see pages 14 and 15 for technical data) RCDT310 n that indicates that all three phases are present. A green LED
RCDT320 n indicates the phase is present while a red LED shows a missing
Earth
RCDT330 n phase connection. The unit has a tough case designed for an resistance
Rubber armoured n n n industrial environment and is supplied with long fused test testers
Weatherproof to IP54 n n n leads with croc-clips and prods.
Test leads included n n n
Calibration certificates included n n n The PSI410 is self powered from the supply and requires no
Warranty upgradeable to 3 years FREE n n n batteries. Electrical
test kits
Batteries included n n n
Smart brief case n n n
n LED clockwise and counter clockwise phase rotation
indication
n Audible indication of direction Accessories
n Phase condition LEDs

MTK310: Standard electrical test kit n Fused test leads

n MIT310 Insulation and continuity tester n Dual phase colour identification Voltage
detector,
n LTW315 Earth loop tester n CAT IV 600 V Socket
n Warranty upgradeable to 3 years FREE tester
n RCDT310 RCD tester

MTK320: Advanced electrical test kit Clamp and


n MIT320 Insulation and continuity tester with insulation and multimeters
continuity limit alarms
n LTW325 Earth loop tester with R1+R2 and Zmax measurement
Solar and
n RCDT320 RCD tester with Programmable RCD testing capability earth
leakage
MTK330: Result storage and downloading Extension testing

test kit
n MIT330 Insulation and continuity tester as MIT320 but
test lead and coil Appliance
with storage and downloading testers
n 30 metre and 50 metre versions
n LTW335 Earth loop tester as LTW325 but with storage
n Suitable for direct R2 measurements
and downloading
n Easy to re-wind cable with tangle-free cable guide
n RCDT330 RCD tester as RCDT320 but with storage
and downloading n Compact and light design Cable fault
locator
Compact extension test lead for direct R2 measurements so
eliminating the need for crossover connections. The furthest
point in the circuit can be easily verified, and every earth point
on the circuit checked for integrity prior to energising. Network
performance
tester

Code
50 m extension lead, green, with 2.4 mm safety plug ETL50 Other
30 m extension lead, green, with 2.4 mm safety plug ETL30
Megger
products

About
Megger

18 ELECTRICAL TEST KITS ACCESSORIES 19


Voltage testers
MFT
Multifunction
Volt finder and flashlight testers

TPT320
MFT
VF3 AC voltage detector with
Electrician’s
certification
insulation
n AC / DC voltage from 12 to 690 V tester
Low power consumption, offering many hours of flashlight
n Continuity Electrical
illumination from one set of alkaline batteries.
test kits
Identifying live conductors, finding a break in a wire, verifying n Phase rotation
Industrial
a blown fuse, and detecting the presence of a.c. voltage. n LCD / LED display insulation
n Bright LED torch Part P
testers
kits
n CAT IV 600 V rating Combined
The new TPT320 features LED and LCD displays that provide loop and
High voltage
RCD testers
both AC and DC voltage measurement from 12 to 690 volts. In insulation
testers
addition, a continuity range of 0 to 500 kOhm is included.
Designed to be used on RCD and RCBO protected circuits
without causing tripping, the unit also has the ability to Low
resistance
indicate phase rotation, has an audible sounder to confirm testers
continuity as well as the presence of voltage. With a built in
high power LED torch, IP64 case and CAT IV 600v safety rating,
the TPT320 is the ideal site tool to conform with current safe Earth loop
isolation procedures. An additional safety feature is the ability tester
to indicate the presence of voltage even in the event of the
internal battery being exhausted.
Earth
resistance

Socket interface adaptor testers

SIA45 Electrical
test kits

Sometimes known as a breakout lead the SIA45 allows sockets


to be tested without disassembly.
n Prevents damage to connections Accessories
n Reduces test time
n Decoration

n Colour
remains intact
coded for simplicity of use
Proving unit Voltage
detector,
n Makes

n Remains
testing easy where access to socket is limited
safe if left inadvertently connected to live supply
MPU690 Socket
tester

Good practice demands that a two-pole tester is proved on a


Clamp and
known live source or proving unit both before and after use. multimeters
The Megger MPU690 is a convenient method to prove the safe
operation of all two-pole testers and Drummond test lamps.
n Capable of testing two-pole voltage detectors and test Solar and
earth
lamps due to 10 W output leakage
n Step voltage LEDs indicate voltage being generated. 50 V, testing
100 V, 230 V, 400 V and 690 V
n Generates a.c. waveform for a true test
Appliance
n Compact design that has an integral magnet for attaching testers
to the cabinet encourages routine safety checks
n Automatic on and off conserves batteries
n Low battery indication gives ample warning to
replace batteries Cable fault
locator
n Warranty upgradeable to 3 years FREE

Network
performance
tester

Other
Megger
products

About
Megger

20 VOLTAGE DETECTOR, SOCKET TESTER VOLTAGE DETECTOR, SOCKET TESTER 21


Clamps and multimeters
MFT
Fork multimeter 400 A a.c. clampmeter 400 A a.c. 600 V Multifunction
testers
a.c. / d.c. 20 MΩ
DCM330 DCM310 clampmeter MFT
with
Electrician’s
certification
Classic multimeter n Easy to read
n 200 A a.c. Open-Jaw current
measurement n Manual operation DCM320 insulation
tester
Electrical
AVO300 n 0.1 V to 1000 V auto-ranging a.c. and
d.c. voltage measurement
n Low cost
n Tough
n
n
20 MΩ resistance range
Continuity buzzer
test kits
Industrial
series n 0.1 Ω to 20.00 MΩ Resistance range
n Continuity buzzer and diode check
This easy to use clampmeter is
ideal to rapidly check the current
n Auto-ranging insulation
Part P
testers
n Auto off to conserve kits
n Non-contact detection of a.c. voltage flowing with the minimum of Combined
Straight forward and tough batteries
n CATIV 600 V fuss. loop and
multimeter High voltage
The Megger DCM330 is suitable for use The DCM320 is a low cost RCD testers
insulation
n Auto-ranging function
anywhere where there is a requirement to data hold current clamp and testers
n Separate fuse and battery multimeter. It is supplied
measure a.c. current in single unshielded
compartment, allows both blister packed complete with
conductors less than 16mm diameter, a.c./
to be replaced without test leads, batteries and Low
d.c. voltages up to 1000 V, or resistances
breaking the calibration carry case. resistance
up to 20 MΩ. testers
seals
DCM310
n Rubber-armoured case
has an integral stand and
hanger DCM320 Earth loop
tester
n Large uncluttered display
n AVO310 has a backlight
n CAT III 600 V safety
DCM330 600 A a.c. / d.c, Earth
resistance
Powerful range of tough
multimeters
600 V a.c. / d.c. clampmeter testers

DCM340 Electrical
n d.c. current range test kits

n Frequency counter
n Analogue bar graph

AVO410 n
n
Back light
Large jaws
Accessories

More sophisticated and safer multimeter n Auto off to conserve batteries


n 
Voltage, current and resistance measurement
The DCM340 is an a.c. and d.c. current Voltage
n 
True rms on a.c. functions detector,
clamp and multimeter that offers Socket
n 
Auto ranging but with the option of manual range selection exceptional value and is particularly suited tester
n 
Max and min measurements to solar PV commissioning. It is supplied
n 
Data hold blister packed complete with test leads,
n 
Continuity and diode testing batteries, user guide and carry case. Clamp and
multimeters
600 μF capacitance and 60 MHz frequency ranges
n 
n 
Tough rubber holster
DCM340
n 
CAT IV 600 V safety Solar and
earth
leakage
testing

AVO300 AVO310 AVO410 DCM310 DCM320 DCM330 DCM340


Current ranges A a.c. 10 A 10 A 0.6 mA, 6 mA, 20 A, 200 A, 40 A, 200 A, 200 A 60 A, 400 A, Appliance
6 A 10 A 400 A 400 A 600 A
testers
True rms n

Multimeters series A d.c.



10 A 10 A 0.6 mA, 6 mA,
6 A 10 A
60 A, 400 A,
600 A
Cable fault
accessories Voltage range

V a.c.
Trms
1000 V 1000 V 750 V
n
200 V, 600 V 200 V, 1000 V 400 V, 600 V
locator

V d.c. 1000 V 1000 V 1000 V 200 V, 600 V 200 V, 1000 V 400 V, 600 V
Resistance range Ω 40 M 40 M 600, 6 k, 60 k, 200, 2 k, 200 k, 200, 2 k, 200 k, 400
600 k, 6 M 60 M 2 M, 20 M 2 M, 20 M Network
Continuity range Buzzer n n n n n n performance
tester
Diode n n
Auto-ranging n n n n n n
Backlit display n n n
Other
Data hold n n n n n
Megger
Max/min hold n n n n products
Conductor size 27 mm 27 mm 16 mm 35 mm
1002-001 1002-015
Other Warranty upgradeable
Replacement test lead set 500 mA fused test lead set
to 3 years FREE n n n
About
Safety rating CATIII 600 V CATIII 600 V CATIV 600 V CATIII 600 V CATIII 600 V CATIV 600 V CATIII 600 V
Megger

22 CLAMP AND MULTIMETERS CLAMP AND MULTIMETERS 23


Solar PV and earth leakage testing Portable Appliance Testers
MFT
Multifunction
testers

MFT
with

Earth leakage clampmeter PAT300 series


Electrician’s
certification
insulation
Special features tester
Electrical
DCM300E A choice of two fast PAT testers which offer the operator
manual and automatic operation without the complexity test kits
DCM300E – a high resolution a.c. of data storage. The PAT300 series allows the user to select n Full PAT functionality with the Industrial
n Versatile high resolution a.c. current clamp, ideal for current clamp insulation
a range of tests, such as those for a CLASS I asset, simply by option of flash test Part P
checking nuisance tripping RCDs testers
pressing the “CLASS I” button, and then initiate the test by kits
n 4 ranges 30 mA range (0.01 mA resolution), 300 mA, 30 A n Automatic or manual operation
pressing the “TEST” button. When the results are displayed Combined
and 300 A loop and
they are coded green for a pass and red for a fail. However, n Continuous operation High voltage
n 31⁄2 digit LCD with analogue bar graph RCD testers
if a particular test needs to be repeated, there are direct insulation
n Data hold access buttons dedicated to specific tests. The instant-restart n Quickest tester in its class testers

DCM300E is perfect for measuring of earth leakage current in a feature speeds testing when moving from one room to n Simple push button control
circuit where the RCD repeatedly trips out. The measured result another, restarting in exactly the same menu location where
it was left. Low
will quickly identify whether the tripping is caused by excessive resistance
leakage current, or if the RCD itself is faulty. PAT310 is the PAT tester for those electricians who testers
SEE TABLE ON PAGE 27 for SPECIFICATION
occasionally do testing and don’t want the complexity
of database management and are happy to make out
certificates by hand. Earth loop
PAT350 is similar to the PAT310 but with the added benefit tester
DCM300E
Current ranges a.c 30 mA, 300 mA, 30 A, 300 A.
of flash testing. Because of its high through-put capabilities
Photovoltaic kits Data hold
Max conductor size
n
40 mm
and the speed at which it gives results, it is ideal for
applications such as tool hire companies and service centres. Earth
Safety rating CATIII 300 V Of particular interest to tool hire companies, as well as resistance
PVK300 series Warranty upgradeable to
3 years FREE n
service and repair organisations, is the PAT300 series ability
testers

PVK300 kits supply all the instrumentation you require in to run high current bond tests virtually continuously,
addition to your MFT to site, commission and test a solar PV without the fear of the tester over-heating.
Electrical
installation to IEC62446, packed in a single pouch. n Instant re-start
test kits
PVK320 includes an auto-ranging, CAT IV, 10 A d.c. AVO410 n 200 mA bond test and the option of 25 A and 10 A bond
multimeter that allows the short circuit current of a panel to be test on the PAT350
read directly, as well as the PVM210 n Test lead null
PVK330 includes the DCM340 a 600 A a.c./d.c clamp n Flash testing at a choice of 1.5 kV or 3 kV (PAT350 only) Accessories
multimeter which speeds the measurement of array stings n Repeated high current bond testing possible
with out the need for disconnection. It can also measure d.c. n Insulation testing at 250 V and 500 V
voltages to 600 V.
n Fully tests appliances to what ever the standard is Voltage
detector,
n Extension and IEC lead testing including polarity, earth Socket
PVK320 PVK330 continuity, L-N continuity and L-N-E insulation tester
n Standard differential leakage test plus
AVO410 CAT IV multimeter
DCM340 Clamp multimeter
n
n Solar PV testing Irradiance n Protective conductor or touch current leakage test
Clamp and
meter n Substitute earth leakage test at 40 V a.c.
PVM210 Irradiance meter n n
multimeters
MC3 to MC4 adaptor testleads n n n Full plug-in 30 mA RCD testing ½ x IDN, IDN, 5 x IDN
MC4 to 4 mm plug testleads n n
n Integral fuse checker

PVM210 Solar and


earth
n Single unit for one handed use increasing safety on ladders leakage
testing
and roofs
n Perfect for measurement of incident light for PV panel short
circuit current calculation PAT300 accessories Appliance
testers
n 1999 W/m2 range on 33⁄4 digit LCD display
n Camera mount fixing for accurate placement

The pocket-size PVM210 is perfect for use on sloping roofs or


at the top of ladders because it has the solar detector built in Cable fault
to the top. This is enhanced by its large clear display and hold locator
function.
It is used for initially choosing optimum position for a PV
installation and for measuring the solar power for the Network
performance
calculation of short circuit current to confirm the performance tester
of the PV panel for certification. 6220-639 1000-768
110 V extension lead 415 V 4-pin adaptor
On the rear of the meter is a universal camera thread that adaptor”
allows mounting for precise readings if required, also a Other
protective pouch is included with each instrument. Megger
products

About
Megger

24 SOLAR AND EARTH LEAKAGE TESTING PORTABLE APPLIANCE TESTERS 25


Portable Appliance n 10,000 asset on-board data storage n Extension and IEC lead testing including polarity, earth MFT
Multifunction
continuity, L-N continuity and L-N-E insulation testers
n Large easy to ready colour screen
Testers n
n
Instant re-start
200 mA bond test and the option of 25 A and 10 A bond
n
n
Standard differential leakage test plus
Protective conductor or touch current leakage test
MFT
with
n Substitute earth leakage test at 40 V a.c. Electrician’s
PAT 400 series n
test on the PAT450
Test lead null n Simple RCD test or full 30 mA RCD testing ½ x IDN, IDN,
certification
insulation
tester
n Repeated high current bond testing possible 5 x IDN Electrical
n Integral fuse checker test kits
Two new PAT testers with full database functionality based n Insulation testing at 250 V and 500 V
on the well received PAT300 series. The PAT 400 series n Load functional test for 230 V appliances Industrial
insulation
introduces a new level of convenience and speed to PAT Part P
testers
testing using on-board test results storage. kits
Combined
Testing to the latest edition of the Code of Practice for the
loop and
In-Service Inspection and Testing of Electrical Equipment High voltage
RCD testers
includes differential, touch and alternative or substitute PAT310 PAT350 PAT410 PAT450 insulation
testers
earth leakage tests. The PAT400 series offers sufficient Supply 230 V with supply measurement n n n n
memory for the test results of 10,000 assets with the proven Earth bond/continuity 200 mA n n n n
10 A n n
long duty cycle, testing simplicity and speed of the PAT300
25 A n n Low
series. In use the PAT400 series has a large bright colour resistance
Bond lead null n n n n
screen for clear test results and simple navigation through testers
Insulation test 250 V n n n n
the menus. 500 V n n n n
The menus have been simplified to make operation faster Alternative leakage tests Substitute n n n n
and more intuitive. Five soft-keys give direct access to Differential n n n n Earth loop
frequently used functions making navigation through the Touch current n n n n tester
menus even faster and the tester even more productive, Functional test VA measurement n n n n

offering a greater return on investment. Extension lead tests Earth bond n n n n


Insulation n n n
The PAT400 series provides quick and easy access to records Polarity n n n n
Earth
in the database and the data can be downloaded using a resistance
Portable RCD tests ½ x IDN, 1 x IDN, 5 x IDN at 0° and 180° n n n n testers
standard USB memory stick. For rapid data entry the PAT400 Flash test 1.5 kV and 3.0 kV n n
series has a choice a large QWERTY or QWERTZ keyboard, PAT410 perfect for those happy to bond test solely at Other features Low-profile light weight n n
this helps to reduce typing errors. To speed up testing still 200 mA. The smallest, lightest of the PAT400 series weighs Auto test routine n n n n
further there is the option of a low cost barcode scanner Manual testing n n n n Electrical
only 2.7 kg. test kits
and barcode label printer. Configurable tests times n n n n
PAT450 in addition to the three bond tests and 230 V Selectable pass limits n n n n
operation this tester offers 1.5 kV and 3.0 kV flash testing Fuse check n n n n
and a quick test facility which allows repeated use of a Large colour display n n n n
single test, making the perfect tool for hire and repair Data handling 10,000 record on-board storage n n Accessories
workshops Download to USB memory stick n n
USB barcode scanner and printer option n n
Supplied accessories Carry case with lead storage pouch n n n n
Combined continuity, earth bond and insulation test lead n n n n Voltage
detector,
Red extension lead adaptor n n n n Socket
Flash test lead n n tester
Calibration certificate n n n n

Clamp and
multimeters

PAT400 series accessories Solar and


Special features earth
leakage
testing
Vast on-board memory to keep
n 
you on the job longer
Appliance
Continuous operation, no need
n  testers
to stop and wait for the tester
to cool down 6220-639 110 V
n Instant re-start as you move extension lead adaptor 1000-768 Cable fault
locator
from room to room testing
n  Soft keys to speed you through
the testing process Network
performance
n  Full PAT testing including RCD tester
testing 1001-047 Barcode Brother PT-2430 Pass/
scanner fail barcode printer
n  Quick test access to single test Other
functions Megger
products
n  Most productive tester in its
class 1000-771
About
Megger

26 PORTABLE APPLIANCE TESTERS PORTABLE APPLIANCE TESTERS 27


Cable fault locators Network Ethernet Tester
MFT
Multifunction
testers
Special features
TDR mark3 series NET200 MFT
with
Electrician’s
n Network Analysis – RTT, Link partner ability, certification
Using a Time Domain Reflectometer (TDR) is a well established NET200 is the latest, all-in-one network qualification tool. It insulation
IP Scan tester
method for finding the location of faults in metallic power or measures logical network performance. It provides the round-
Electrical
data cables. In the past TDRs have had a reputation of being trip time (RTT) to measure network speed under dynamic n Auto measurement – with selection of tests test kits
expensive and difficult to use but now, the Megger TDR Mark3 and static configuration protocol and IP scanning to show
series has put paid to that. the information on all the terminals connected into the local n LAN measurement – Distance, Wiremap, Industrial
insulation
network. It can also evaluate the capability of link connections Crosstalk, Impedance and Continuity Part P
testers
An AUTO selection option, fast pulse and built in blocking filter
to support specific network speeds and duplexity (half- or full- n Coax capability – graphic or numeric TDR kits
ensures that the most effective selection depending on the Combined
duplex).
range required, helping rapid diagnosis of the TDR trace. In (selectable) loop and
High voltage
addition on the TDR1000/3 and TDR1000/3P, dual cursors allow The device provides the physical information of the LAN cable RCD testers
n Tone Generator – 1kHz analogue tone insulation
complete flexibility, giving the operator full control and instant under test such as; Cable length, distance to fault (open or testers
indication of distance between two points. short) and wire map (pass, fail). With the graphic user interface signal
supplied by 128x64 LCD and serial communication port, field
n Acurate and easy fault finding because of resolution as low
engineers can easily apply the device to network testing, Low
as 0.1 m resistance
transfer the stored data to their PCs and print reports via
n Ultra fast 2 ns pulse for near end fault identification testers
software.
n Trace hold and comparison not TDR500/3
n Auto selected output impedance (between 25, 50, 75 and n Network qualification in one device
100 Ω) n Measures logical network performance Earth loop
n Power blocking filter not required n Checks physical condition of cables tester
n For use on Telecom TNV-3 circuit, or 150 V CAT IV power n Coax and RJ45 connections
circuits n Autotest capability
n Environmental protection to IP54 Earth
n Tone Generator built in
n High resolution backlit monochrome LCD resistance
n Li-ion battery testers
n Adjustable display contrast
n 2 year warranty
TDR500/3 TDR1000/3 TDR1000/3P
Electrical
Range Capability 0.2 m to 5000 m 0.2 m to 5000 m 0.2 m to 5000 m test kits
Minimum Pulse 2ns 2ns 2ns
Blocking Filter YES YES YES
Cursors 1 2 2
Memory Trace Hold Trace Hold with Trace Hold with
Accessories
Live Trace Overlay Live Trace Overlay
Sample Time 60ns 60ns 60ns
Backlight Yes Yes Yes
Auto Power Off Yes Yes Yes Voltage
detector,
Test leads Miniature clip Miniature clip Standard clip
Socket
10 A fused tester
CAT Rating 300V CAT III 300V CAT III 300V CAT III
150V CAT IV 150V CAT IV 150V CAT IV
IP Rating IP54 IP54 IP54
Clamp and
multimeters

Solar and
earth
leakage
testing

Appliance
testers

TDR mark3 series


accessories
Cable fault
NET200 series accessories locator

Network
performance
tester

Other
Megger
products
6231-652 1002-015 2003-200 2003-189 2003-196
Miniature clip test 500 mA fused test lead set d.c. vehicle charge lead Kit carry bag Remote identifier #5.
There are 8 available About
Megger

28 CABLE FAULT LOCATOR NETWORK PERFORMANCE TESTER 29


MFT
Multifunction
Other Megger products you may find useful About Megger testers

MFT
with
Electrician’s
Made in Europe certification
insulation
TTR25 Hand-held n M
 easures turns ratio, excitation current and polarity of windings in single- and three-
tester
single and three-phase phase distribution and power transformers (tested phase by phase), potential and current All the products shown in this catalogue are engineered
Electrical
transformer tester and made at our factory in England. If you’ve ever visited
transformers, and tapped transformers. User can operate the test set one handed. Eliminates test kits
the need to bend down to operate the instrument and speeds up testing time. It is rugged, England by ferry, you’ve probably seen our building – there’s Industrial
with a high impact, shock resistant case, yet very light at 870 g. a big Megger logo on our car park. Everyone hears how insulation
Part P
testers
manufacturing is moving out of Europe to Asia, but Megger
kits
employs hundreds of people in Sweden, Germany, Switzerland Combined
and France. As a professional electrician, you have a right to loop and
High voltage
demand the very best electrical test equipment. By specifying RCD testers
insulation
Megger, not only will you get the best. testers
EZ-Thump cable n A
 practical and efficient solution for the fast on spot fault location. The EZ-Thump is the
fault locator compact and light weight, battery or mains powered solution for the fault location in MV or
LV cables. It is the perfect solution for areas of lower distribution density and failure rate. Low
resistance
testers

Earth loop
tester
Calibration and repair service
PA9+ Power n O
 n-sitepower quality analysis and data retrieval without a computer. Intelligent download
Megger and many of its distributors operate fully traceable
quality analyser and real time graphical trending of Harmonics, THD and TDD. It now has a faster digital signal
calibration and repair facilities ensuring your instrument Earth
processor, 12 MB of internal, non-volatile memory, and incorporated auxiliary power input resistance
continues to provide the high standard of performance and testers
capabilities. Includes Metrosoft® software and remote communications.
workmanship you expect from Megger. These facilities are
complemented by a worldwide network of approved repair
and calibration companies, to offer excellent in-service care for Electrical
your Megger products. test kits
For information on having your instrument calibrated or
Sverker is the n S
 VERKER has long been acknowledged as the single phase relay test of choice. A well repaired number please call +44 (0)1304 502 101.
most popular designed, rugged instrument SVERKER is the most popular relay tester because of its
single-phase Accessories
ease-of-use and unequalled reliability.
relay test set

Certified to ISO 9001:2008 and


Voltage
ISO14001:2004 detector,
Socket
Megger’s manufacturing plant in Dover tester

is certified to the full operational


n Batteriesare becoming an increasingly important part of modern life with their use in Engineered for electrical contractors
Programma
Torkel 840
requirements of ISO 9001:2008 and the Clamp and
standby power and maintained supply units. Megger has added to its BITE range of battery Many of our engineers sit on European and international multimeters
battery load impedance testers with the Programma Torkel range of battery load units which allow technical committees, and we have regular meetings with manufacturing process strictly adheres
unit
the batteries to be tested in service, by adjusting to include the load current in the test all the big trade associations. We also have close contacts to the highest standards for quality,
Solar and
parameters. with training organisations, electrical contractor groups and reliability and safety. It is also certified earth
associations, and government organisations. If anyone knows leakage
how important it is to understand the needs of electrical
to ISO14001:2004, the standard for testing

contractors, it’s Megger. So when new legislation or rules are environmental management systems
introduced – whether it’s Part P of the Building Regulations in
Appliance
FRAX101 Sweep n F
 ollowing an incident the quickest way to assess the condition of a transformer, before the UK, ITC BT03 in Spain, VDE 0100 in Germany, XP C16-600 in testers
frequency
returning it to service, is to run a FRA test. The FRAX101 is the smallest, most rugged France, RoHS, the WEEE Directive or IEC 60364, you can count
response
analyser instrument and it offers the highest dynamic range and accuracy. on Megger to put your interests first.
Established originally in the late 1800s, the company has been Cable fault
manufacturing test and measurement instruments designed locator
to perform preventive maintenance and troubleshooting for
decades. Megger products help customers all over the world
improve their efficiency, reduce costs, and meet standards. Network
It operates globally with dedicated field sales teams and performance
SMRT protective n S
 MRT tester and AVTS® software from Megger raises the standard and lowers the weight for tester
relay test set the automatic testing and management of protective relay systems. SMRT offers traditional distributors located all over the world and manufacturing
manual and semi-automatic testing of the relay system whilst the AVTS package offers fully plants in the United States, Sweden and the United Kingdom.
automatic testing as well as relay maintenance schedule management. The commitment of Megger to industry is reflected in its Other
Megger
technical leadership and in being the first to design and products
introduce many key products.

About
Technical specifications are subject to change without notice. Megger

30 OTHER MEGGER PRODUCTS ABOUT MEGGER 31

You might also like