Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR report

Job info
Job ID : Reason :
Contractor : NOVKER Operator A :
Customer : Operator B :
Test date : 26-Nov-19 (9:19:33 PM GMT+7:00) File : suralaya baru core15-1310.sor

Cable info
Fiber ID : Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 0.041 dB Avg. splice loss : ---
Span length : 0.1025 km Max. splice loss : ---
Average loss : 0.398 dB/km Span ORL : <57.53 dB

OTDR trace

dB

25.00

20.00

1
15.00 2

10.00

5.00

0.00
100 200 300 400 500 m

Signature : _________________________ Date : 27-Nov-19


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 0.000


Fiber Section (0.1025 km) 0.041 0.398 0.041
2 0.1025 Reflective Fault 0.000 48.9 0.041

Marker info
A : 0.0000 km, 15.164 dB B : 0.0000 km, 15.164 dB
a : 0.0000 km, 15.164 dB b : 0.0000 km, 15.164 dB
A to B distance : 0.0000 km, 0.000 dB A to B ORL : *****
3-pt. reflectance : ***** A to B LSA att. : -0.000 dB/km
4-pt. Ev. loss : 0.000 dB

Test and cable setup


Wavelength : 1310 nm (SM-9µm) Acq. time : 5s
Filename : suralaya baru core15-1310.sor Pulse width : 50 ns
Hardware : Helix factor : 0.00 %
Serial number : Splice loss threshold : 0.100 dB
Software : N/A Reflectance threshold : -40.0 dB
Range : 0.5228 km End-of-fiber threshold : 10.000 dB
IOR : 1.468000
RBS : -80.00

Signature : _________________________ Date : 27-Nov-19