This document provides specifications for the Draeger Vista 120 S Patient Monitor for invasive monitoring. It measures ECG, SpO2, respiration rate, non-invasive blood pressure, temperature, invasive blood pressure, and cardiac output. Key features include a 12-inch touchscreen display, built-in recorder, and support for up to 11 waveforms. Accessories include ECG cables, electrodes, NIBP cuff, SpO2 sensor, and more.
Original Description:
Original Title
Spesifikasi Vista 120 S Patient Monitor - Invasive bayi
This document provides specifications for the Draeger Vista 120 S Patient Monitor for invasive monitoring. It measures ECG, SpO2, respiration rate, non-invasive blood pressure, temperature, invasive blood pressure, and cardiac output. Key features include a 12-inch touchscreen display, built-in recorder, and support for up to 11 waveforms. Accessories include ECG cables, electrodes, NIBP cuff, SpO2 sensor, and more.
This document provides specifications for the Draeger Vista 120 S Patient Monitor for invasive monitoring. It measures ECG, SpO2, respiration rate, non-invasive blood pressure, temperature, invasive blood pressure, and cardiac output. Key features include a 12-inch touchscreen display, built-in recorder, and support for up to 11 waveforms. Accessories include ECG cables, electrodes, NIBP cuff, SpO2 sensor, and more.
Parameter : ECG, SpO2, RR, NBP, Temp, IBP, C.O Merk : Draeger Features : Bedside monitor for ER, HCU, ICU, OR, RR advanced measurements : Scalable: offers a choice of three models to meet diverse clinical needs patient : data : Easy to use: provides quick access menu, hard keys, and a rotary knob : Built-in recorder: saves time by providing documentation when needed TECHNICAL DATA Display Specifications Touch Screen Display Display screen : 12.” color TFT Resolution: : 800 × 600 Waveforms : Maximum of 11 waveforms Ukuran Dimensi : 344 mm (Weight) × 266 mm (Height) × 145 mm (Depth) Berat : 5 kg Power supply : 100 V to 240 V~, 50 Hz/60 Hz Battery life : 350 min (At 25±2 C, with (a) new fully charged Battery charge time : ≤ 390 min, 100% charge SUPPORTED PARAMETER ECG Lead mode : 3-lead : I, II, III Heart rate calculation Range : ADU: 15 to 300 bpm : PED/NEO: 15 to 350 bpm PVC Range : ADU: 0 to 300 PVCs/min : PED/NEO: 0 to 350 PVCs/min ST value Range : -2.0 to 2.0 mV RESPIRATION Method : Impedance between RA-LL, RA-LA Measurement lead : Default lead II Measurement Range Adult : 0 to 120 rpm Neo/Ped : 0 to 150 rpm Sweep : 6.25 mm/s, 12.5 mm/s, 25mm/s, 50mm/s Apnea Alarm time setup : 10s, 15s, 20s, 25s, 30s, 35s, 40s, default is 20s NIBP Method : Oscillometric Mode : Manual, Auto, Continuous Measuring interval in auto mode : 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, and 480 min Continuous : 5 min, interval is 5 s Measuring type : Systolic Pressure, Diastolic Pressure, Mean Pressure Alarm type : SYS, DIA, MAP Pulse Rate Measuring range : 40 to 240 bpm Accuracy : ±3 or 3.5 %, whichever is larger SpO2 Measuring range : 0 to 100 % Resolution : 1% TEMPERATURE Technique : thermal resistance Position : Skin IBP : dual invasive pressure Technique : Direct Invasive measurement Measuring range Art : 0 to 300 mmHg PA : -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg P1/P2 : -50 to 300 mmHg Cardiac Output (C.O) Technique : Thermodilution Technique Measure Parameters : C.O, TB, TI Trend review Short : 1 hr, 1 s. resolution Long : 120 hrs, 1 min. resolution Review : 1200 sets NIBP measurement data RECORDER Record width : 48 mm Paper speed : 12.5 mm/s 25 mm/s, 50 mm/s Trace : Up to 3 waveforms Accessories ECG Cable : 1 pc ECG ELECTRODE : 1 pc NIBP cuff : 1 pc SpO2 SENSOR : 1 pc Skin temp probe : 1 pc Printing paper : 1 pc IBP Cable : 2 pc Cardiac Output (C.O) : 1 pc