Professional Documents
Culture Documents
Q6001N JS4 (E) (2) Thermodynamic Performance Sheet
Q6001N JS4 (E) (2) Thermodynamic Performance Sheet
2. Basis data…………………………………………………………… 2
3. Thermal performance…………………………..…………………… 2
7. Flow-power curve……………………………………………………21
1. Calculation task
Design thermal performance of turbine N110-8.83/535.
2. Basis data
Temp. of
Normal initial parameters rotate speed Rated power Max. power
cooling water
Items Po To n Ne Ne Tn
MPa ℃ r/min kW kW ℃
Value 8.83 535 3000 110000 118487.8 30/33
3. Thermal performance
Inlet steam Feeding water Feeding water Steam Heat
Electric Power
Item Condition flow temp. ratio consumption consumption
t/h ℃ % kW kg/kW.h kcal/kW.h
THA(1) 403.0 228.2 0 110291.7 3.654 2172.6
THA(2) 404.5 228.2 3 110028.7 3.676 2163.3
TRL(1) 415.0 229.9 0 110304.6 3.762 2229.5
TRL(2) 416.5 229.9 3 110009.6 3.786 2220.0
VWO(1) 436.0 232.7 0 118487.8 3.680 2169.6
VWO(2) 436.0 232.5 3 117846.7 3.700 2158.4
T-MCR(1) 415.0 229.8 0 113304.9 3.663 2170.9
T-MCR(2) 417.0 229.9 3 113187.9 3.684 2161.1
75%THA 300.0 212.6 0 82698.5 3.628 2218.7
50%THA 213.0 199.0 0 55008.9 3.872 2424.3
Min. power 150.0 182.3 0 38405.9 3.906 2514.8
HP Heater exscinded 366.0 158.2 1 110121.1 3.324 2228.5
4. Summary for parameters in each stage under typical condition
Stage 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17/22 18/23 19/24 20/25 21/26
Pressure after stage MPa 5.9215 5.1632 4.4229 3.7265 3.1052 2.6326 2.2198 1.8329 1.503 1.2176 0.9591 0.7637 0.6033 0.4616 0.3354 0.2342 0.137 0.078 0.0395 0.0148 0.008
Specific volume after stage m3/kg 0.056 0.063 0.071 0.082 0.095 0.109 0.125 0.146 0.171 0.203 0.245 0.294 0.355 0.439 0.565 0.759 1.224 2.023 3.731 9.071 16.018
THA (1)
Enthalpy after stage kJ/kg 3393.9 3357.5 3317.8 3274.4 3229.2 3189.5 3147.1 3101.1 3055.1 3008.3 2957.3 2911 2865.4 2816.4 2761.5 2704.4 2630.3 2554.4 2472.2 2372.2 2319.7
Temprature after stage ℃ 489.3 468.9 448.3 425.8 402.3 381.6 359.7 332.6 308.3 283.5 256.4 231.7 207.2 180.8 151.1 125.4 108.8 92.9 75.6 53.7 41.5
Stage steam flow t/h 403 397.57 397.57 397.57 397.57 367.68 367.68 367.68 367.68 343.97 343.97 323.59 323.59 324.39 324.39 324.39 157.59 147.56 147.56 138.42 138.42
Stage power kW 8958.9 4013.9 4565.5 4967.9 5171.6 4232.2 4505.7 4877.2 4849.1 4620.3 5028.2 4318.2 4252.8 4592.7 5140.9 5375.6 3242.2 3296.6 3577.4 4114.1 2501.9
Go= 403.00t/h Ne=110291.7kW
Enthalpy after stage kJ/kg 3395.8 3359.4 3319.5 3275.8 3230.3 3190.5 3147.9 3101.8 3055.6 3008.6 2957.4 2911.1 2865.4 2816.4 2761.4 2704.1 2629.8 2553.9 2471.5 2371.7 2320.1
Temprature after stage ℃ 490.2 469.8 449 426.4 402.8 382 360.1 332.9 308.5 283.6 256.4 231.6 207.2 180.8 150.9 125.2 108.6 92.7 75.4 53.5 41.5
Stage steam flow t/h 404.5 399.05 399.05 399.05 399.05 368.04 368.04 368.04 368.04 343.61 343.61 322.43 322.43 323.23 323.23 323.23 156.82 146.46 146.46 137.09 137.09
Stage power kW 8774.9 4044.1 4602.2 5012.5 5225.1 4247.4 4524.2 4901.2 4879.5 4628.9 5043.7 4304.2 4239.7 4579.9 5129.7 5372.3 3237.5 3270.9 3557.6 4069.1 2444
Go= 404.50t/h Ne=110028.7kW
Enthalpy after stage kJ/kg 3400 3363.6 3323.7 3280.2 3234.9 3195 3153.5 3107.3 3061 3014.2 2963.2 2916.8 2871 2821.7 2766.3 2708.9 2634.8 2558.8 2477.9 2383.1 2357.9
Temprature after stage ℃ 492.7 472.3 451.6 429 405.4 384.7 363.1 335.9 311.5 286.7 259.6 234.8 210.2 183.7 153.7 126.4 109.7 93.8 76.8 56.3 49.1
Stage steam flow t/h 415 409.44 409.44 409.44 409.44 378.33 378.33 378.33 378.33 352.81 352.81 332.77 332.77 333.59 333.59 333.59 162.03 151.81 151.81 144.48 144.48
Stage power kW 8533.7 4142.3 4712.7 5130.2 5343.7 4364.9 4539.6 5042 5018.5 4739.7 5153.2 4456.6 4391.9 4747.3 5325.5 5558.5 3337.2 3392 3625.5 4077.3 1441.9
Go= 415.00t/h Ne=110304.6kW
Enthalpy after stage kJ/kg 3401.9 3365.4 3325.4 3281.6 3235.9 3196 3154.3 3107.9 3061.4 3014.4 2963.2 2916.8 2871 2821.7 2766.2 2708.7 2634.3 2558.4 2477.3 2382.9 2358.5
Temprature after stage ℃ 493.6 473.1 452.3 429.6 405.9 385.1 363.5 336.2 311.7 286.8 259.6 234.7 210.2 183.6 153.6 126.2 109.5 93.6 76.5 56.2 49.1
Stage steam flow t/h 416.5 410.93 410.93 410.93 410.93 378.57 378.57 378.57 378.57 352.28 352.28 331.45 331.45 332.27 332.27 332.27 161.19 150.62 150.62 143.13 143.13
Stage power kW 8340.5 4172.9 4751 5177.3 5400.9 4378.8 4556.4 5064.8 5048 4745.6 5165.9 4440.1 4376.2 4731.7 5311.1 5551.2 3330.5 3364.9 3602.4 4026 1394.2
Go= 416.50t/h Ne=110009.6kW
Summary for parameters in each stage under typical condition(accessory1)
Stage 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17/22 18/23 19/24 20/25 21/26
Pressure after stage MPa 6.4493 5.6223 4.8133 4.0521 3.3721 2.8577 2.408 1.986 1.6257 1.319 1.0415 0.8291 0.6544 0.5001 0.3618 0.253 0.1478 0.0841 0.0424 0.0158 0.008
VWO (1)
Specific volume after stage m3/kg 0.052 0.058 0.066 0.076 0.089 0.102 0.117 0.136 0.16 0.19 0.229 0.275 0.332 0.411 0.53 0.708 1.143 1.891 3.495 8.541 16.006
Enthalpy after stage kJ/kg 3410.9 3374.1 3333.9 3289.9 3244 3203.8 3161.9 3115.1 3068.3 3021.3 2970.3 2923.5 2877.2 2827.4 2771.2 2713.7 2639 2562.4 2479.3 2378.3 2319.6
Temprature after stage ℃ 498.7 478.2 457.2 434.4 410.5 389.5 367.8 343.5 315.7 290.8 263.7 238.6 213.8 187 156.5 127.9 111.1 94.9 77.3 55 41.5
Stage steam flow t/h 436 430.22 430.22 430.22 430.22 396.78 396.78 396.78 396.78 368.15 368.15 348.68 348.68 349.53 349.53 349.53 169.71 158.73 158.73 148.34 148.34
Stage power kW 7665.1 4391 4998.6 5446.1 5681.4 4618 4806.4 5343 5325.8 4960 5383.5 4706.7 4643.6 5025.6 5660.5 5836.1 3521.6 3579.1 3890.1 4452.3 2943.2
Go= 436.00t/h Ne=118487.8kW
Specific volume after stage m3/kg 0.052 0.058 0.066 0.076 0.089 0.102 0.117 0.137 0.161 0.191 0.23 0.276 0.334 0.413 0.534 0.714 1.155 1.911 3.54 8.644 16.007
Enthalpy after stage kJ/kg 3410.5 3373.6 3333.3 3289.2 3243 3202.8 3160.8 3113.9 3066.9 3019.8 2968.6 2921.9 2875.7 2825.9 2769.7 2712.2 2637.4 2560.9 2477.6 2376.9 2319.5
Temprature after stage ℃ 498.5 477.9 456.9 434 410 389 367.2 342.9 314.9 290 262.8 237.8 213 186.2 155.7 127.6 110.7 94.6 77 54.8 41.5
Stage steam flow t/h 436 430.22 430.22 430.22 430.22 395.75 395.75 395.75 395.75 366.44 366.44 346.11 346.11 346.96 346.96 346.96 168.24 156.94 156.94 146.36 146.36
Stage power kW 7713.3 4400 5011.6 5465.2 5708.8 4611.5 4802.4 5343.7 5334.3 4944.8 5373.9 4666.2 4603.9 4983.6 5615.3 5796.3 3499.4 3533.6 3849.8 4383.7 2852.5
Go= 436.00t/h Ne=117846.7kW
Specific volume after stage m3/kg 0.055 0.061 0.069 0.08 0.093 0.106 0.122 0.143 0.167 0.198 0.239 0.287 0.346 0.428 0.552 0.739 1.193 1.972 3.64 8.873 16.014
Enthalpy after stage kJ/kg 3401 3364.4 3324.5 3280.9 3235.4 3195.5 3152.8 3106.6 3060.3 3013.4 2962.4 2915.9 2870.1 2820.9 2765.5 2708.1 2633.7 2557.5 2474.9 2374.5 2319.7
Temprature after stage ℃ 493.1 472.6 451.9 429.2 405.6 384.8 362.8 335.6 311.2 286.3 259.2 234.4 209.8 183.3 153.3 126.4 109.6 93.7 76.3 54.2 41.5
Stage steam flow t/h 415 409.44 409.44 409.44 409.44 378.33 378.33 378.33 378.33 352.89 352.89 332.81 332.81 333.62 333.62 333.62 162.04 151.67 151.67 142.07 142.07
Stage power kW 8419.3 4154.5 4725.8 5144.1 5357.5 4376.1 4659.9 5046.6 5022 4745.8 5159.2 4460.2 4394.2 4747.5 5320.2 5564.5 3347 3401 3692.9 4241 2663
Go= 415.00t/h Ne=113304.9kW
Specific volume after stage m3/kg 0.055 0.061 0.069 0.08 0.093 0.106 0.122 0.143 0.167 0.198 0.24 0.288 0.347 0.429 0.554 0.743 1.201 1.986 3.672 8.943 16.014
Enthalpy after stage kJ/kg 3401.7 3365.1 3325 3281.1 3235.4 3195.4 3152.6 3106.2 3059.7 3012.7 2961.5 2915.1 2869.3 2820 2764.7 2707.2 2632.6 2556.4 2473.7 2373.5 2319.5
Temprature after stage ℃ 493.5 473 452.2 429.4 405.6 384.8 362.7 335.4 310.9 286 258.8 233.9 209.4 182.8 152.9 126.2 109.4 93.5 76 54 41.5
Stage steam flow t/h 417 411.43 411.43 411.43 411.43 379.05 379.05 379.05 379.05 352.7 352.7 331.84 331.84 332.65 332.65 332.65 161.36 150.62 150.62 140.77 140.77
Stage power kW 8374.7 4186.6 4766.2 5193.6 5417.8 4393.1 4680.8 5074 5056.8 4752.3 5172.1 4444.4 4380.4 4732.6 5305.8 5557.7 3342.9 3374.8 3673.1 4195 2604
Go= 417.00t/h Ne=113187.9kW
Summary for parameters in each stage under typical condition(accessory2)
Stage 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17/22 18/23 19/24 20/25 21/26
Pressure after stage MPa 4.3731 3.8177 3.2755 2.7669 2.314 1.965 1.6608 1.3763 1.1368 0.9168 0.7144 0.569 0.4496 0.3443 0.2507 0.1758 0.1036 0.0591 0.0302 0.012 0.008
75% THA
Specific volume after stage m3/kg 0.074 0.082 0.093 0.107 0.124 0.141 0.162 0.189 0.22 0.261 0.318 0.382 0.46 0.569 0.73 0.987 1.584 2.615 4.786 11.079 16.126
Enthalpy after stage kJ/kg 3340.9 3306.2 3268.4 3227.2 3184.5 3146.6 3107.2 3063.5 3020.3 2974 2922.9 2878.2 2834.3 2787.1 2734.4 2680 2608.6 2534.9 2455.7 2361.6 2331.4
Temprature after stage ℃ 457.7 439.8 420.2 398.9 376.8 357.1 333.5 310.6 287.9 263.4 236.3 212.4 188.9 163.5 135 116.3 100.7 85.7 69.3 49.4 41.5
Stage steam flow t/h 300 295.6 295.6 295.6 295.6 275.7 275.7 275.7 275.7 265.24 265.24 244 244 244.62 244.62 244.62 119.11 111.98 111.98 106.5 106.5
Stage power kW 11014 2842.8 3231.3 3504.1 3630 3028 3139.8 3470.7 3420.3 3515 3875.3 3139.4 3087 3330.2 3718.9 3858.8 2361.1 2423.1 2613.9 2985.3 1203.4
Go= 300.00t/h Ne= 82698.5kW
Specific volume after stage m3/kg 0.098 0.109 0.123 0.14 0.161 0.188 0.214 0.247 0.295 0.35 0.428 0.511 0.613 0.782 1.014 1.355 2.097 3.584 6.546 14.817 20.097
Enthalpy after stage kJ/kg 3308.6 3277.6 3243.8 3207.4 3170.2 3134.2 3099.9 3063 3023.4 2981.2 2934.3 2893.7 2853.9 2806.9 2755.4 2701.5 2638.1 2565.1 2488.7 2396.8 2376.2
Temprature after stage ℃ 437.1 421.2 403.7 385 362.9 343.8 325.8 306.4 285.4 263.2 238.4 216.8 195.7 170.4 142.8 113.7 93 77.8 62.3 43.8 37.7
Stage steam flow t/h 213 209.39 209.39 209.39 209.39 196.2 196.2 196.2 196.2 191.17 191.17 175.03 175.03 175.48 175.48 175.48 85.82 80.94 80.94 77.57 77.57
Stage power kW 9677.8 1804.5 2041.4 2193.4 2241.2 1958.3 1948.3 2091.2 2153.5 2310 2567.2 2048.1 2004.5 2289.7 2605.3 2741.1 1510.4 1640.5 1826.7 2123.5 663.2
Go= 213.00t/h Ne= 55008.9kW
Specific volume after stage m3/kg 0.136 0.151 0.17 0.194 0.222 0.259 0.295 0.341 0.406 0.483 0.588 0.703 0.843 1.074 1.391 1.841 2.859 4.888 8.788 17.6 20.258
Enthalpy after stage kJ/kg 3256 3226.4 3194.2 3159.4 3124 3089.5 3056.6 3021.2 2983.3 2942.8 2897.9 2858.7 2820.3 2775 2725.4 2675.2 2615.1 2544.3 2471.6 2393.3 2396.7
Temprature after stage ℃ 407.6 392.5 373.2 355.1 336.7 318.5 301.3 282.7 262.7 241.4 217.7 196.9 176.6 152.3 125.7 98.7 84.3 69.8 55.5 40.4 37.7
Stage steam flow t/h 150 147.07 147.07 147.07 147.07 138.73 138.73 138.73 138.73 135.34 135.34 124.75 124.75 125.07 125.07 125.07 61.38 58.14 58.14 56.5 56.5
Stage power kW 8945.3 1209.4 1372.1 1472.4 1501.1 1329.5 1320 1420.3 1460.6 1571.1 1742.1 1410.4 1379.1 1573.5 1789.5 1825.9 1024.4 1143.8 1248.3 1320.2 63.5
Go= 150.00t/h Ne= 38405.9kW
Pressure after stage MPa 5.583 4.9132 4.2666 3.6666 3.1399 2.6814 2.2848 1.9165 1.6037 1.2978 1.0198 0.8126 0.6424 0.4917 0.3572 0.2513 0.1497 0.0849 0.0426 0.0159 0.008
Specific volume after stage m3/kg 0.059 0.066 0.074 0.084 0.095 0.108 0.123 0.142 0.165 0.195 0.237 0.284 0.343 0.424 0.546 0.721 1.137 1.885 3.499 8.549 16.087
Enthalpy after stage kJ/kg 3387.4 3353.9 3318 3279.8 3241.5 3203.3 3165.4 3124.7 3084.5 3036.4 2984 2936.9 2890.5 2840.4 2784.3 2726.9 2654.5 2576.7 2492.2 2390.1 2330.3
Temprature after stage ℃ 483.4 466.1 447.5 427.7 407.8 387.9 368.2 344 322.7 297.4 269.6 244.5 219.7 192.9 162.6 131.5 111.4 95.2 77.5 55.1 41.5
Stage steam flow t/h 366 360.91 360.91 360.91 360.91 360.91 360.91 360.91 362.26 362.26 362.26 338.14 338.14 339.45 339.45 339.45 165.77 159.94 159.94 148.72 148.72
Stage power kW 8780.3 3357.2 3760.6 3987.2 4004.6 3995 3964.6 4254.7 4196.1 4981.4 5443.4 4587.9 4519 4900.8 5492.7 5649.8 3332.9 3647.5 3979.5 4508 3000.3
Go= 366.00t/h Ne=110121.1kW
5. Sealing leakage
1.THA (1)
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 403.0
Make-up water ratio: 0%
0.2 t/h
1.2 t/h B
B G
0.05 t/h A
2.28 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.744 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
158.2
662.4 403.0
0.496 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.654 2172.6 110291.7 36.01
2.THA (2)
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 404.5
Make-up water ratio: 3%
0.2 t/h
1.2 t/h B
B G
0.05 t/h A
2.297 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.741 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
158.2
662.4 415.0
0.496 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.762 2229.5 110304.6 35.10
4.TRL (2)
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 416.5
Make-up water ratio: 3%
0.2 t/h
1.2 t/h B
B G
0.05 t/h A
2.372 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.762 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
158.2
662.4 436.0
0.496 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.680 2169.6 118487.8 36.07
6.VWO (2)
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 436.0
Make-up water ratio: 3%
0.2 t/h
1.2 t/h B
B G
0.05 t/h A
2.496 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.794 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
158.2
662.4 415.0
0.496 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.663 2170.9 113304.9 36.04
8.T-MCR (2)
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 417.0
Make-up water ratio: 3%
0.2 t/h
1.2 t/h B
B G
0.05 t/h A
2.373 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.761 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
158.1
661.9 300.0
0.497 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.628 2218.7 82698.5 35.27
10. 50%THA
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 213.0
Make-up water ratio: 0%
0.2 t/h
1.2 t/h B
B A
0.052 t/h A
1.23 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.503 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
151.0
632.2 213.0
0.498 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.872 2424.3 55008.9 32.28
11. Min. power
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 150.0
Make-up water ratio: 0%
0.2 t/h
1.2 t/h B
B A
0.053 t/h A
0.864 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.513 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 0
137.2
574.4 150.0
0.499 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.906 2514.8 38405.9 31.114
12. HP Heater exscinded
Units:
MPa ℃ A:To sealing heater
kJ/kg t/h B:To auto-sealing system
8.83 535.0 G:To Deaerator
3475.0 366.0
Make-up water ratio: 1%
0.2 t/h
1.2 t/h B
B A
0.051 t/h A
1.355 t/h F -0.178 t/h 0.286 t/h 0.286 t/h
0.784 t/h C 0.378 t/h 0.056 t/h 0.095 t/h A 0.095 t/h
E B B A B
Deaerator 30
125.6 3.66
158.2
662.4 369.7
0.497 t/h
Steam Heat Electric Thermal B
consumption consumption Power efficiency
kg/kWh kcal/kW.h kW %
3.324 2228.5 110121.1 35.127
7. Flow-power curve
120000.0
110000.0
100000.0
90000.0
Electric Power(kW)
80000.0
70000.0
60000.0
50000.0
40000.0
30000.0
100 150 200 250 300 350 400 450