Gea P&id

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

4

4 2

6
4 4

2 81-W-22
6
4

81-FL-03 4

4
4 4

81-K-20 81-KM-20

81-SH-20

LOCAL CONTROL PANEL DCS AND/OR HMI PD


MVS
4
TYPICAL TYPICAL

MCC
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80

56 56

1
54 54

2
4
52 52
3

4
50 50

1
2
48 4 48

2" 2" 2" 2"

46 46
4

81-W-20
44 44

2" 2"
42 42

2"
40 40

2"

38 38

36 36

34 34

32 32

30 30

28 28

26 26

4
24 24

4
22 22

20 20

4
4 1
2
18 18

16 16

81-V-21
14 14

12 12

10 10

REFRIGERANT 4
CHARGE
8 8

6 6

4 4

2 2

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80
1

3
4
4
4
4
4 4
5
5
4

4 2
3

MCC 4
4
81-V-22
81-EH-21
4

81-FL-02B

81-FL-02A

81-PM-20A 81-PM-20B

81-P-20A
M 81-P-20B
M
SEE TYP.3 SEE TYP.3
2" 2" 2" 2" 2" 2" 2"

4
81-W-21

2"

2"
PIPING SIMBOLOGY VALVES FOR PROCESS SPECIFICATION PIPING FITTINGS
"Y" TYPE STRAINER FLANGES
PRIMARY PROCESS LINE
GATE VALVE CHECK VALVE AIR RESERVOIR
/ FLOW DIRECTION
"T" TYPE STRAINER UNION NIPPLE
GLOBE VALVE DISCHARGE VALVE
SECONDARY PROCESS LINE AND NETWORKS (SCHROEDER OR YARWAY TYPE)
/ FLOW DIRECTION
BLIND FLANGE
BALL VALVE THREE-WAY VALVE
TEMPORARY
STRAINER VENT
HEAT TRACED LINE
BUTTERFLY VALVE WELDED CAP
DIAPHRAGM VALVE
PS
PERMANENT SCREWED PLUG
ELECTRICAL TRACING ROTARY PLUG / NEEDLE VALVE
STRAINER
SG SIGHT GLASS
FOUR-WAY VALVE
SPECIAL VALVE HOSE CONNECTION
JACKETED LINE STEAM TRAP

CATALYST VALVE CLASS CHANGE


FLEXIBLE HOSE SPECTACLE BLIND CLOSE
CATALYST OR SPECIAL
PROCESS LINE BUTTERFLY VALVE
AND RESTRICTION ORIFICE "DRIP RING" ON CATALYST LINES
MOTOR OPERATED VALVE EXPANSION JOINT

BATTERY OR PACKAGE SPECTACLE BLIND OPEN


LIMITS DRAIN CUP
ANGLE VALVE

REDUCER
VORTEX BREAKER
FREE DRAINING / GRAVITY FLOW DOUBLE DISK SLIDE VALVE

SLOPE

TYPICAL 1 TYPICAL 2 INSTRUMENT AIR

4
4

4
VALVES

GENERAL PIPING VALVE

GENERAL SYMBOLS FOR VALVE.


THE VALVE TYPE WILL BE DEFINED
GENERAL CONTROL VALVE BY DETAIL ENGINEERING
CONTRACTOR, AXENS REPRESENTS
GENERAL VALVE ON P&IDs UNLESS
OTHERWISE SPECIFIED FOR
PROCESS REASONS
ESD VALVES SHALL HAVE PARTIAL STROKE TEST FACILITIES;
GENERAL ON/OFF VALVE SMART POSITIONER SHALL COMMUNICATE
WITH UCP VIA A DEDICATE 4-20mA HART AO

BATTERY LIMITS

TYPICAL 3

M M

INLET/OUTLETS, INDICATION ARROWS


MCC MCC
OR OR OR OR
FROM/TO SHEET CONNECTIONS
DWG :
ELECTRICAL SOFTWARE INSTRUMENT
SECONDARY
PRIMARY 2359 4
PROCESS LINE
SIGNAL OR DATA LINK SUPPLY PROCESS LINE
AND NETWORKS

OR OR OR OR BATTERY LIMITS

SECONDARY
ELECTRICAL SOFTWARE INSTRUMENT PRIMARY
PROCESS LINE
SIGNAL OR DATA LINK SUPPLY PROCESS LINE
AND NETWORKS

FLOW DIRECTION DIMENSION ARROW NETWORK IN / OUT

4
4
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80

4
56 56

4 1
54 54

4 2

52 52
3
4

50 4 50

5 4
48 1 48
4 2

46 46

44 44

42 42

81-V-20
40 40

38 38

36 36

34 34

1
4
2
32 32

2" 2"
30 30

2" 2"

28 28

81-E-20 4 5

26 26
4

2" 2" 2" 2" 2" 2"


24 24

81-J-02
22 22

20 20

18 18
5

4
16 16

14 14

12 12
81-J-01

10 10

8 8

6 6

4 4

2 2

0 0

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80

You might also like