5 4 3 2 1 Client:

GULF HOTELS COMPANY W.L.L

SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION

GENERAL NOTES
MISCELLANEOUS SCHEMATIC SYMBOLS MINIATURE LED LIGHTING ELECTRICAL OUTLET FIRE ALARM SYSTEM 1- THE LAYOUT DRAWINGS DO NOT SHOW ALL THE SYSTEMS, ITEMS, OR ACCESSORIES COVERED UNDER THE SCOPE OF
ELECTRICAL WORKS TO BE EXECUTED . THE LAYOUT DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT Consultant:
CEILING MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT ABOVE FALSE CEILING PHOTOELECTRIC SMOKE DETECTOR OR SPECIALIST DRAWINGS AND SPECIFICATIONS .
FUSE X No. LO LIGHTING OUTLET S
NUMBER, a = RESPECTIVE CONTROLLING SWITCH) ALONG WITH REMOTE INDICATOR.
PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, 2- DO NOT SCALE FROM THE LAYOUT DRAWINGS, WORK ACCORDING TO ARCHITECTURAL OR ELECTRICAL DETAILS UNLESS
MECHANICAL OR ELECTRICAL INTERLOCK X No. No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING LO SWITCHED LIGHTING OUTLET S OTHERWISE INDICATED .
K E UNDER RAISED FLOOR PHOTOELECTRIC SMOKE DETECTOR
a SWITCH)
WALL / CANOPY / TREE MOUNTED (X = FIXTURE TYPE, No.
X No. 3- THE SIZE OF CONDUITS IS IN GENERAL NOT SHOWN ON THE DRAWINGS .THE SIZE OF ALL CONDUITS SHALL BE SELECTED
DISCONNECTOR (ISOLATOR) = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING SWITCH) LO LIGHTING OUTLET FED FROM EMERGENCY SUPPLY S OPTICAL BEAM SMOKE DETECTOR - TRANSMITTER
a IN ACCORDANCE WITH THE "REGULATIONS" AND AS A FUNCTION OF THE NUMBER & SIZE OF THE INDICATED CONDUCTORS,
ALL CONDUITS SHALL BE AS SPECIFIED WITH A MINIMUM SIZE OF ∅20mm UNLESS OTHERWISE INDICATED.
SWITCH-DISCONNECTOR X No. WALL MOUNTED PROVIDED WITH BATTERY KIT (X = FIXTURE LO SWITCHED LIGHTING OUTLET FED FROM EMERGENCY SUPPLY OPTICAL BEAM SMOKE DETECTOR - REFLECTOR
ENSURE MAXIMUM 40% OF FILLING SHALL BE ADOPTED IN CONDUITS.
S
a TYPE, NUMBER, a = RESPECTIVE CONTROLLING SWITCH)

MOTORIZED/WITHDRAWABLE CIRCUIT 4- ALL SWITCHES, SOCKET OUTLETS, TELEPHONE OUTLETS, etc... SHALL BE INSTALLED WITH THEIR REQUIRED PLATES,
LO LIGHTING OUTLET (WALL MOUNTED) S PHOTOELECTRIC SMOKE DETECTOR
D BREAKER REFER TO SPECIFICATIONS FOR DESCRIPTON & TYPE OF PLATES FOR EACH PARTICULAR APPLICATION . D
E FIXED CIRCUIT BREAKER LO SWITCHED LIGHTING OUTLET (WALL MOUNTED) S
E = ELECTRICALLY OPERATED DUCT SMOKE DETECTOR 5- ALL LIGHTING PANELBOARDS SHALL BE INSTALLED WITH TOP ENDS AT 180cm ABOVE F.F.L. UNLESS OTHERWISE INDICATED .

LIGHTING OUTLET FED FROM EMERGENCY SUPPLY


CURRENT TRANSFORMER LED LIGHTING LO (WALL MOUNTED) S H MULTI-CRITERIA DETECTOR 6- EARTH CONTINUITY CONDUCTORS ARE NOT INDICATED ON THE DRAWINGS, BUT SHALL BE RUN WITH ALL CIRCUITS IN
ACCORDANCE WITH REGULATIONS .
No. SUSPENDED/SURFACE MOUNTED (X = FIXTURE TYPE, No. = SWITCHED LIGHTING OUTLET FED FROM EMERGENCY SUPPLY
M MOTOR X LO H RATE OF RISE/FIXED TEMEPERATURE THERMAL DETECTOR
a CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING SWITCH) (WALL MOUNTED)

PROVIDED WITH BATTERY KIT SUPPLY (X = FIXTURE TYPE, ELECTRICAL OUTLET


X No. xA
G GENERATOR No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. EO F MANUAL STATION
a Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF)
SWITCH)

X No. WALL MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT xA SWITCHED ELECTRICAL OUTLET CD

A AMMETER W.P. EO CEILING MOUNTED STROBE LIGHT(CD:CANDELA LEVEL)


a NUMBER, a = RESPECTIVE CONTROLLING SWITCH) Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF)

PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY
CD

X No. xA WALL MOUNTED STROBE LIGHT(CD:CANDELA LEVEL)


V VOLTMETER No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. EO
a Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) ABBREVIATIONS
SWITCH)
FLEXIBLE LINEAR LIGHTING FIXTURE (X = FIXTURE TYPE, SWITCHED ELECTRICAL OUTLET
X No. xA FIRE ALARM HORN WITH STROBE LIGHT
VS VOLTAGE SELECTOR No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. EO FED FROM EMERGENCY SUPPLY
a Y (CD:CANDELA LEVEL) SS/ SUBSTATION c
T CIRCUIT No.
SWITCH) (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) CD

PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, ELECTRICAL OUTLET (WALL MOUNTED)
X No. xA (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) MFACP MDB/ MAIN DISTRIBUTION BOARD F.F.L. FINISHED FLOOR LEVEL
kWh DIGITAL KILOWATT HOUR METER No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. EO MAIN FIRE ALARM CONTROL PANEL
a SWITCH) Y
Notes:
No. CEILING MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT xA SWITCHED ELECTRICAL OUTLET (WALL MOUNTED) DP/ DISTRIBUTION PANEL NGL NATURAL GROUND LEVEL
POWER TRANSFORMER X W.P. EO FACP FIRE ALARM CONTROL PANEL
a NUMBER, a = RESPECTIVE CONTROLLING SWITCH) Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) 1.ELECTRICAL EQUIPMENT NAMING CONVENTION:
MSSP/ MASTER SWITCH SELECTOR PANEL ZZ-YY-XX
ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY LP/ LIGHTING PANELBOARD
xA ZZ: EQUIPMENT ACRONYM
RECTIFIER X No. No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. (WALL MOUNTED) AOM CONTROL MODULE
EO YY: SITE ‘ST’ / BUILDING NAME ‘GRD, TLT, SCR, AVR’
a SWITCH), EPROVIDED WITH BATTERY KIT SUPPLY Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) PP/ POWER PANELBOARD UPS UNINTERRUPTIBLE POWER SUPPLY XX: BUILDING SERIAL NUMBER AS PER AR NAMING CONVENTION
SWITCHED ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY
xA (WALL MOUNTED)
BATTERIES FLOOR STANDING OFFICE TASK LUMINAIRE W.P. EO AIM MONITOR MODULE
Y MB/ METER BOARD ATS AUTOMATIC TRANSFER SWITCH
(x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF)
CONDUIT STUB UP TO EQUIPMENT OR BENCH MCC/ MOTOR CONTROL CENTER CCTV CLOSED CIRCUIT TELEVISION SYSTEM
POWER SUPPLY FLOODLIGHT / SPIKE LIGHT IM ISOLATOR MODULE
SWITCHED ELECTRICAL OUTLET, ABOVE FALSE CEILING
VT MOUNTED, XX INDICATES FOR: MCP/ MOTOR CONTROL PANEL MATV MASTER ANTENNA TELEVISION SYSTEM
VOLTAGE TRANSFORMER FCU: FAN COIL UNIT CCTV SYSTEM
WP xA VAV: VARIABLE AIR VOLUME
xx LCP/ LIGHTING CONTROL PANEL W.P. WEATHER PROOF
AV: AIR VALVE
UPS-n UNINTERRUPTIBLE POWER SUPPLY (n = REFERENCE) INTERIOR CEILING DOME CAMERA , FIXED TYPE
AC: AIR CURTAIN
(x = AMPERE RATING, W.P. = WEATHER PROOF) LDP/ LIGHTING DIMMING PANEL MFACP MAIN FIRE ALARM CONTROL PANEL
UNSWITCHED, WALL MOUNTED ELECTRICAL OUTLET XX INDICATES FOR:
ECB-n EMERGENCY CENTRAL BATTERY (n = REFERENCE) CP: CLEAN AGENT CONTROL PANEL, SP: ARRAY SPEAKER, TAP: WATER INTERIOR WALL MOUNTED DOME CAMERA , FIXED TYPE
WP xA SP SYNCHRONIZATION PANEL FARP FIRE ALARM REPEATER PANEL
TAP, HD: HAND DRYER, TD: TOILET DISPENSER, BMS: BUILDING
X Y XX MANAGEMENT SYSTEM, RTU: REMOTE TERMINAL UNIT FOR PMS, FA:
Y: TAP-OFF UNIT, X: REDUCER UNIT FIRE ALARM CONTROL PANEL (MAIN, REPEATER, OR MIMIC PANEL), POLE MOUNTED DOME CAMERA, PTZ TYPE FP FEEDER PILLAR SC SHORT CIRCUIT
BUSWAY SPUR: GENERAL SPUR OUTLET (x = AMPERE RATING, W.P. = WEATHER
PROOF)
UNSWITCHED ELECTRICAL OUTLET, ABOVE FALSE PFC/ POWER FACTOR CORRECTION IC INTERRUPTING CAPACITY
BUSDUCT END CAP WP XX xA CEILING MOUNTED, XX INDICATES FOR: MD: MOTORIZED POLE MOUNTED DOME CAMERA , FIXED TYPE
DAMPER, MSFD: MOTORIZED SMOKE FIRE DAMPER, LTF:
PATIENT'S LIFT, SPUR: GENERAL SPUR OUTLET (x = ECBS/ EMERGENCY CENTRAL BATTERY IDF INTERMEDIATE DISTRIBUTION FRAME
AMPERE RATING, W.P. = WEATHER PROOF) SYSTEM
LOW VOLTAGE PANEL EXIT SIGN FIXTURES WALL MOUNTED DOME CAMERA, PTZ TYPE

N.O.
EARTHING & LIGHTNING PROTECTION SYSTEMS FTTx FIBER TO THE X ACP ACCESS CONTROL PANEL
LOW VOLTAGE PANEL CEILING MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT
LV-n NUMBER, W.P. = WEATHER PROOF, STRUCTURED CABLING SYSTEM AP ACCESS POINT
(FREE STANDING TYPE, n = REFERENCE) EARTH PIT OR EARTH ELECTRODE, X: E:FOR EARTHING PIT, VMS VARIABLE MESSAGE SIGNS
W.P. X INDICATES THE ESCAPE DIRECTION)
N.O. L:FOR LIGHTNING PIT, T: FOR TELECOM. PIT
WALL MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT X
DISTRIBUTION, LIGHTING & POWER DISTRIBUTION BOARD NUMBER, W.P. = WEATHER PROOF, (AN"E" WRITTEN BEFORE ANY OF PS PAGING STATION
C W.P. X INDICATES THE ESCAPE DIRECTION) EARTH TEST LINK mT/nD/xV
INFORMATION OUTLET (m = NUMBER OF TELEPHONE THE ABOVE MEANS FED FROM C
N.O. PORTS, n = NUMBER OF DATA PORTS, X= NUMBER OF EMERGENCY POWER SUPPLY)
REF. No. FLAG MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT C CAMERA
RECESSED NUMBER, W.P. = WEATHER PROOF, Z W VIDEO PORTS, W=WALL MOUNTED IF ADDED,
W.P. X INDICATES THE ESCAPE DIRECTION) Z: C=CCTV,
TRANSIENT EARTH CLAMP
REF. No. h1 90cm ABOVE F.F.L.
SEMI RECESSED SWITCHES mT/nD/xV
HC ROOF CONDUCTOR INFORMATION OUTLET (CEILING MOUNTED)
h2 120cm ABOVE F.F.L.
REF. No. Z
W.P ONE-WAY (W.P = WEATHER PROOF)
SURFACE MOUNTED
E.P (E.P = EXPLOSION PROOF)
DOWN CONDUCTOR TO EARTH PIT DATA RACK h3 150cm ABOVE F.F.L.
DC
REF. No. LIGHTING CONTROL PANEL a, b ONE-WAY, TWO GANG
R LCP (R = INDICATES REMOTE CONTROLLED) (a, b = CONTROLS FIXTURES DENOTED a OR b) h4 30cm ABOVE COUNTER LEVEL
VC VERTICAL CONDUCTOR FTTX PANEL
REF. No. MASTER SELECTIVE SWITCH PANEL a, b, c ONE-WAY, THREE GANG h5 CEILING MOUNTED
R MSSP (R = INDICATES REMOTE CONTROLLED) (a, b, c = CONTROLS FIXTURES DENOTED a OR b OR c) BC BONDING CONDUCTOR AUDIO-VISUAL SYSTEMS
FPI FEEDER PILLAR
PULL
EARTHING AND ROOF LIGHTNING CONDUCTOR
ROCK SPEAKER
EXISTING DISTRIBUTION BOARD P WITH PILOT LIGHT S
EARTHING LATTICE

MOTOR CONTROL CENTERS


K WITH KEY General Key Plan:
EARTH ROD, X: E:FOR EARTHING ROD, L: FOR LIGHTNING LINE-ARRAY SPEAKER
X ROD, T: FOR TELECOM. ROD
MCC-n MOTOR CONTROL CENTER (n = REFERENCE) TWO-WAY
BONDING BETWEEN COPPER CONDUCTORS
a, b TWO-WAY, TWO GANG
MCP-n MOTOR CONTROL PANEL (n = REFERENCE) (a, b = CONTROLS FIXTURES DENOTED a OR b)
EARTH BAR

m COMBINATION STARTER THREE-WAY (INTERMEDIATE), ONE GANG


CONNECTION TO REINFORCEMENT BARS
HL FACTORY PANEL BY OTHERS
FP THREE-WAY (INTERMEDIATE), TWO GANG
(HL = MOUNTED AT HIGH LEVEL OR ABOVE FALSE CEILING) LEVEL CHANGE

VFD STAND-ALONE V.F.D STARTER O CEILING MOUNTED OCCUPANCY SENSOR


AIR TERMINAL

FEEDERS V CEILING MOUNTED VACANCY SENSOR


CLAMP CONDUCTOR
CABLE/GROUP OF CABLES, UNDER GROUND .
REF.
(METHOD OF INSTALLATION SHOWN ON DRAWINGS) PUSHBUTTON (MOMENTARY)
REF = FEEDER REFERENCE
REF. CABLE/GROUP OF CABLES, SURFACE MOUNTED .
T TIMER
(METHOD OF INSTALLATION SHOWN ON DRAWINGS)
xA SWITCH DISCONNECTOR (SAFETY SWITCH)
OR NORMAL BUS DUCT (FOR SLDs) ST np+N (x = Amp.RATING, np = NUMBER OF POLES, NEUTRAL LINK)
HL (HL = MOUNTED AT HIGH LEVEL OR ABOVE FALSE CEILING)
P (ST: PROVIDED WITH SHUNT TRIP)(P: PEDESTAL MOUNTED)
OR EMERGENCY BUS DUCT (FOR SLDs) WALL MOUNTED OCCUPANCY SENSOR,
X = TYPE (PW = PIR WIDE VIEW, PH = PIR HALLWAY,
Z PS = PIR WALL SWITCH)
OR UPS BUS DUCT (FOR SLDs) XY Y : C = CENTRAL CONTROL SYSTEM DEVICE,
CI = CENTRAL CONTROL SYSTEM INTELLIGENT DEVICE
Z = CONTROLLED CIRCUIT NUMBER
BUS DUCT (FOR CABLE ROUTING DRAWINGS) CEILING MOUNTED OCCUPANCY SENSOR,
B X = TYPE (P = PIR, U = ULTRASONIC, B
Z UH = ULTRASONIC HALLWAY, D = DUAL-TECHNOLOGY)
25A, 1 PHASE LIGHTING BUSDUCT Y : C = CENTRAL CONTROL SYSTEM DEVICE,
XY Project Name:
CI = CENTRAL CONTROL SYSTEM INTELLIGENT DEVICE
Z = CONTROLLED CIRCUIT NUMBER
32A, 3 PHASE LIGHTING BUSDUCT
D PHOTOCELL, CEILING MOUNTED Consultancy Services for F&B
BRANCH CIRCUITS IN CONDUITS/WIREWAYS
D PHOTOCELL, WALL MOUNTED District at Intercontinental
CO. CONDUIT EMBEDDED IN SLAB OR WALL
(CO = CONDUIT ONLY)
ONE WAY, BED HEAD UNIT MOUNTED SWITCH
Doha Hotel and Residences
CONDUIT ABOVE FALSE CEILING Doha-Qatar
TOUCH SCREEN

CONDUIT EXPOSED
Project Number Q21227-0100D
SOCKET OUTLET
CONDUIT UNDER FLOOR TILES
* SINGLE, * INDICATES FOR:

CONDUIT TURNED DOWN DUPLEX,* INDICATES FOR:


TENDER DESIGN
* C: CEILING MOUNTED TYPE
MON: SUPPLIED FOR MONITOR Package 1
CONDUIT TURNED UP
SINGLE DESK/COUNTER MOUNTED
FEBRUARY 2022
WIRING TRUNKING
DUPLEX DESK/COUNTER MOUNTED
a
UNDER FLOOR TRUNKING WITH FLOOR BOX
(a = TYPE OF BOX, SEE DRAWING)
SINGLE DESK/COUNTER MOUNTED FED FROM UPS

PLUG IN LIGHTING TRUNKING


DUPLEX DESK/COUNTER MOUNTED FED FROM UPS

SKIRTING TRUNKING
THREE PHASE INDUSTRIAL POWER SOCKET OUTLET

VERTICAL WIRING TRUNKING


SINGLE PHASE INDUSTRIAL POWER SOCKET OUTLET

120/240V, SHAVER SOCKET.

RACEWAYS, CABLE SUPPORTS AND RELATED ACCESSORIES


SP 3 Amp. FUSED SPUR LIGHTING OUTLET 0 10/02/2022 APPROVED ISSUE A.Z./A.H.
CABLE TRAY, LADDER TYPE Rev Date Description Appr
SINGLE SUPPLIED FROM UPS

CABLE TRAY, PERFORATED TYPE


R05/R09 2 NO. OF SIMPLEX WEATHER PROOF R05/R09 Issue:
(DUPLEX WEATHER PROOF)
PERFORATED CABLE TRAY, WITH COVER
FILE NAME : Q21227-0100D-GEN-TD-EG-001-Rev0
DUPLEX SUPPLIED FROM UPS
n Ød UNDER GROUND DUCT BANK MODEL NAME :
(n = No. OF DUCTS, d = DIAMETER)
A DUPLEX WITH USB A DRAWN BY: A.A.
DRAWPIT, HANDHOLE OR MANHOLE
T DESIGNED BY: T.S./M.B.
(T = TYPE SHOWN ON DRAWINGS)
FB-n FLOOR BOX (n = REFERENCE FOR TYPE)
CHECKED BY: A.Z./A.H.
CABLE TRAY TURNED UP / DOWN
APPROVED BY: R.B.G.
EQUIPOTENTIAL EARTH BONDING SOCKET

LV LV GENERATOR BURIED LV CABLES Sheet Title


STUB-UP FLOOR CONDUIT

General
General Symbols Notes and
Abbreviations

PLAN NORTH
Sheet No.

Q21227-0100D-GEN-TD-EG-001