GENERAL NOTES
MISCELLANEOUS SCHEMATIC SYMBOLS MINIATURE LED LIGHTING ELECTRICAL OUTLET FIRE ALARM SYSTEM 1- THE LAYOUT DRAWINGS DO NOT SHOW ALL THE SYSTEMS, ITEMS, OR ACCESSORIES COVERED UNDER THE SCOPE OF
ELECTRICAL WORKS TO BE EXECUTED . THE LAYOUT DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT Consultant:
CEILING MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT ABOVE FALSE CEILING PHOTOELECTRIC SMOKE DETECTOR OR SPECIALIST DRAWINGS AND SPECIFICATIONS .
FUSE X No. LO LIGHTING OUTLET S
NUMBER, a = RESPECTIVE CONTROLLING SWITCH) ALONG WITH REMOTE INDICATOR.
PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, 2- DO NOT SCALE FROM THE LAYOUT DRAWINGS, WORK ACCORDING TO ARCHITECTURAL OR ELECTRICAL DETAILS UNLESS
MECHANICAL OR ELECTRICAL INTERLOCK X No. No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING LO SWITCHED LIGHTING OUTLET S OTHERWISE INDICATED .
K E UNDER RAISED FLOOR PHOTOELECTRIC SMOKE DETECTOR
a SWITCH)
WALL / CANOPY / TREE MOUNTED (X = FIXTURE TYPE, No.
X No. 3- THE SIZE OF CONDUITS IS IN GENERAL NOT SHOWN ON THE DRAWINGS .THE SIZE OF ALL CONDUITS SHALL BE SELECTED
DISCONNECTOR (ISOLATOR) = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING SWITCH) LO LIGHTING OUTLET FED FROM EMERGENCY SUPPLY S OPTICAL BEAM SMOKE DETECTOR - TRANSMITTER
a IN ACCORDANCE WITH THE "REGULATIONS" AND AS A FUNCTION OF THE NUMBER & SIZE OF THE INDICATED CONDUCTORS,
ALL CONDUITS SHALL BE AS SPECIFIED WITH A MINIMUM SIZE OF ∅20mm UNLESS OTHERWISE INDICATED.
SWITCH-DISCONNECTOR X No. WALL MOUNTED PROVIDED WITH BATTERY KIT (X = FIXTURE LO SWITCHED LIGHTING OUTLET FED FROM EMERGENCY SUPPLY OPTICAL BEAM SMOKE DETECTOR - REFLECTOR
ENSURE MAXIMUM 40% OF FILLING SHALL BE ADOPTED IN CONDUITS.
S
a TYPE, NUMBER, a = RESPECTIVE CONTROLLING SWITCH)
MOTORIZED/WITHDRAWABLE CIRCUIT 4- ALL SWITCHES, SOCKET OUTLETS, TELEPHONE OUTLETS, etc... SHALL BE INSTALLED WITH THEIR REQUIRED PLATES,
LO LIGHTING OUTLET (WALL MOUNTED) S PHOTOELECTRIC SMOKE DETECTOR
D BREAKER REFER TO SPECIFICATIONS FOR DESCRIPTON & TYPE OF PLATES FOR EACH PARTICULAR APPLICATION . D
E FIXED CIRCUIT BREAKER LO SWITCHED LIGHTING OUTLET (WALL MOUNTED) S
E = ELECTRICALLY OPERATED DUCT SMOKE DETECTOR 5- ALL LIGHTING PANELBOARDS SHALL BE INSTALLED WITH TOP ENDS AT 180cm ABOVE F.F.L. UNLESS OTHERWISE INDICATED .
X No. WALL MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT xA SWITCHED ELECTRICAL OUTLET CD
PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY
CD
PROVIDED WITH BATTERY KIT (X = FIXTURE TYPE, ELECTRICAL OUTLET (WALL MOUNTED)
X No. xA (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) MFACP MDB/ MAIN DISTRIBUTION BOARD F.F.L. FINISHED FLOOR LEVEL
kWh DIGITAL KILOWATT HOUR METER No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. EO MAIN FIRE ALARM CONTROL PANEL
a SWITCH) Y
Notes:
No. CEILING MOUNTED (X = FIXTURE TYPE, No. = CIRCUIT xA SWITCHED ELECTRICAL OUTLET (WALL MOUNTED) DP/ DISTRIBUTION PANEL NGL NATURAL GROUND LEVEL
POWER TRANSFORMER X W.P. EO FACP FIRE ALARM CONTROL PANEL
a NUMBER, a = RESPECTIVE CONTROLLING SWITCH) Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) 1.ELECTRICAL EQUIPMENT NAMING CONVENTION:
MSSP/ MASTER SWITCH SELECTOR PANEL ZZ-YY-XX
ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY LP/ LIGHTING PANELBOARD
xA ZZ: EQUIPMENT ACRONYM
RECTIFIER X No. No. = CIRCUIT NUMBER, a = RESPECTIVE CONTROLLING W.P. (WALL MOUNTED) AOM CONTROL MODULE
EO YY: SITE ‘ST’ / BUILDING NAME ‘GRD, TLT, SCR, AVR’
a SWITCH), EPROVIDED WITH BATTERY KIT SUPPLY Y (x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF) PP/ POWER PANELBOARD UPS UNINTERRUPTIBLE POWER SUPPLY XX: BUILDING SERIAL NUMBER AS PER AR NAMING CONVENTION
SWITCHED ELECTRICAL OUTLET FED FROM EMERGENCY SUPPLY
xA (WALL MOUNTED)
BATTERIES FLOOR STANDING OFFICE TASK LUMINAIRE W.P. EO AIM MONITOR MODULE
Y MB/ METER BOARD ATS AUTOMATIC TRANSFER SWITCH
(x = AMPERE RATING, Y = LABEL, W.P. = WEATHER PROOF)
CONDUIT STUB UP TO EQUIPMENT OR BENCH MCC/ MOTOR CONTROL CENTER CCTV CLOSED CIRCUIT TELEVISION SYSTEM
POWER SUPPLY FLOODLIGHT / SPIKE LIGHT IM ISOLATOR MODULE
SWITCHED ELECTRICAL OUTLET, ABOVE FALSE CEILING
VT MOUNTED, XX INDICATES FOR: MCP/ MOTOR CONTROL PANEL MATV MASTER ANTENNA TELEVISION SYSTEM
VOLTAGE TRANSFORMER FCU: FAN COIL UNIT CCTV SYSTEM
WP xA VAV: VARIABLE AIR VOLUME
xx LCP/ LIGHTING CONTROL PANEL W.P. WEATHER PROOF
AV: AIR VALVE
UPS-n UNINTERRUPTIBLE POWER SUPPLY (n = REFERENCE) INTERIOR CEILING DOME CAMERA , FIXED TYPE
AC: AIR CURTAIN
(x = AMPERE RATING, W.P. = WEATHER PROOF) LDP/ LIGHTING DIMMING PANEL MFACP MAIN FIRE ALARM CONTROL PANEL
UNSWITCHED, WALL MOUNTED ELECTRICAL OUTLET XX INDICATES FOR:
ECB-n EMERGENCY CENTRAL BATTERY (n = REFERENCE) CP: CLEAN AGENT CONTROL PANEL, SP: ARRAY SPEAKER, TAP: WATER INTERIOR WALL MOUNTED DOME CAMERA , FIXED TYPE
WP xA SP SYNCHRONIZATION PANEL FARP FIRE ALARM REPEATER PANEL
TAP, HD: HAND DRYER, TD: TOILET DISPENSER, BMS: BUILDING
X Y XX MANAGEMENT SYSTEM, RTU: REMOTE TERMINAL UNIT FOR PMS, FA:
Y: TAP-OFF UNIT, X: REDUCER UNIT FIRE ALARM CONTROL PANEL (MAIN, REPEATER, OR MIMIC PANEL), POLE MOUNTED DOME CAMERA, PTZ TYPE FP FEEDER PILLAR SC SHORT CIRCUIT
BUSWAY SPUR: GENERAL SPUR OUTLET (x = AMPERE RATING, W.P. = WEATHER
PROOF)
UNSWITCHED ELECTRICAL OUTLET, ABOVE FALSE PFC/ POWER FACTOR CORRECTION IC INTERRUPTING CAPACITY
BUSDUCT END CAP WP XX xA CEILING MOUNTED, XX INDICATES FOR: MD: MOTORIZED POLE MOUNTED DOME CAMERA , FIXED TYPE
DAMPER, MSFD: MOTORIZED SMOKE FIRE DAMPER, LTF:
PATIENT'S LIFT, SPUR: GENERAL SPUR OUTLET (x = ECBS/ EMERGENCY CENTRAL BATTERY IDF INTERMEDIATE DISTRIBUTION FRAME
AMPERE RATING, W.P. = WEATHER PROOF) SYSTEM
LOW VOLTAGE PANEL EXIT SIGN FIXTURES WALL MOUNTED DOME CAMERA, PTZ TYPE
N.O.
EARTHING & LIGHTNING PROTECTION SYSTEMS FTTx FIBER TO THE X ACP ACCESS CONTROL PANEL
LOW VOLTAGE PANEL CEILING MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT
LV-n NUMBER, W.P. = WEATHER PROOF, STRUCTURED CABLING SYSTEM AP ACCESS POINT
(FREE STANDING TYPE, n = REFERENCE) EARTH PIT OR EARTH ELECTRODE, X: E:FOR EARTHING PIT, VMS VARIABLE MESSAGE SIGNS
W.P. X INDICATES THE ESCAPE DIRECTION)
N.O. L:FOR LIGHTNING PIT, T: FOR TELECOM. PIT
WALL MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT X
DISTRIBUTION, LIGHTING & POWER DISTRIBUTION BOARD NUMBER, W.P. = WEATHER PROOF, (AN"E" WRITTEN BEFORE ANY OF PS PAGING STATION
C W.P. X INDICATES THE ESCAPE DIRECTION) EARTH TEST LINK mT/nD/xV
INFORMATION OUTLET (m = NUMBER OF TELEPHONE THE ABOVE MEANS FED FROM C
N.O. PORTS, n = NUMBER OF DATA PORTS, X= NUMBER OF EMERGENCY POWER SUPPLY)
REF. No. FLAG MOUNTED (X = EXIT SIGN TYPE, No. = CIRCUIT C CAMERA
RECESSED NUMBER, W.P. = WEATHER PROOF, Z W VIDEO PORTS, W=WALL MOUNTED IF ADDED,
W.P. X INDICATES THE ESCAPE DIRECTION) Z: C=CCTV,
TRANSIENT EARTH CLAMP
REF. No. h1 90cm ABOVE F.F.L.
SEMI RECESSED SWITCHES mT/nD/xV
HC ROOF CONDUCTOR INFORMATION OUTLET (CEILING MOUNTED)
h2 120cm ABOVE F.F.L.
REF. No. Z
W.P ONE-WAY (W.P = WEATHER PROOF)
SURFACE MOUNTED
E.P (E.P = EXPLOSION PROOF)
DOWN CONDUCTOR TO EARTH PIT DATA RACK h3 150cm ABOVE F.F.L.
DC
REF. No. LIGHTING CONTROL PANEL a, b ONE-WAY, TWO GANG
R LCP (R = INDICATES REMOTE CONTROLLED) (a, b = CONTROLS FIXTURES DENOTED a OR b) h4 30cm ABOVE COUNTER LEVEL
VC VERTICAL CONDUCTOR FTTX PANEL
REF. No. MASTER SELECTIVE SWITCH PANEL a, b, c ONE-WAY, THREE GANG h5 CEILING MOUNTED
R MSSP (R = INDICATES REMOTE CONTROLLED) (a, b, c = CONTROLS FIXTURES DENOTED a OR b OR c) BC BONDING CONDUCTOR AUDIO-VISUAL SYSTEMS
FPI FEEDER PILLAR
PULL
EARTHING AND ROOF LIGHTNING CONDUCTOR
ROCK SPEAKER
EXISTING DISTRIBUTION BOARD P WITH PILOT LIGHT S
EARTHING LATTICE
CONDUIT EXPOSED
Project Number Q21227-0100D
SOCKET OUTLET
CONDUIT UNDER FLOOR TILES
* SINGLE, * INDICATES FOR:
SKIRTING TRUNKING
THREE PHASE INDUSTRIAL POWER SOCKET OUTLET
General
General Symbols Notes and
Abbreviations
PLAN NORTH
Sheet No.
Q21227-0100D-GEN-TD-EG-001
5 4 3 2 1