FLOOR PLAN
0.7000 0.6000
1.0000 1.2000 2.0000 0.4000 0.6000 1.9000
0.4000
1.2000 1.2000
2.1000 2.1000 2.1000 2.1000
1.7000
0.9000 0.9000

D D D W W W W W
1 2 3 1 2 3 4 5

Type Panel Swing Door Type Panel Swing Door Type Flush Swing Door Type Sliding Window Type Sliding Window Type Awning Window Type Fixed Window Type Sliding Door
Materials Wood Materials Wood Materials PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC
Frame Wood Frame Wood Frame PVC Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass
Required 2 sets Required 6 sets Required 4 SETS Required 8 SETS Required 2 SETS Required 3 SETS Required 2 SETS Required 2 SETS

SCHEDULE OF DOORS AND WINDOWS


F1C1 F1C1 F1C1

B1 RB1 RB1
WF1 WF1 B1

WF1 WF1 WF1 B1 B2 B1 RB1 RB2 RB1

B1 B1 RB1 RB1
F1C1 F1C1 F1C1

WF1 WF1
WF1 WF1 B1 B2 B1 RB1 RB2 RB1

RB1 RB1
F1C1 F1C1
B1 B1
F1C1
B3 B3 B3 B3

B3 B3
F2C1 F2C1 F2C1 F2C1

FOUNDATION PLAN AND BEAM SCHEDULE


VARIES

0.30m MIDSPAN 0.30m


L/4 LEFT SUPPORT TOP BARS RIGHT SUPPORT L/4
TOP BARS TOP BARS

LEFT SUPPORT RIGHT SUPPORT


BOTTOM BARS BOTTOM BARS
MIDSPAN
BOTTOM BARS

SCHEDULE OF BEAMS
NUMBER OF REINFORCEMENT STIRRUPS SPACING
MARK DIMENSIONS
@SUPPORT @MIDSPAN 10mm ø REBARS
6-16mm RSB 2-16mm RSB
B1 250x400 1@50, 3@75, 6@100, rest@180
3-16mm RSB 5-16mm RSB
8-16mm RSB 4-16mm RSB
B2 250x400 1@50, 3@75, 6@100, rest@180
4-16mm RSB 8-16mm RSB
3-16mm RSB 2-16mm RSB
B3 250x250 1@50, 3@75, 6@100, rest@180
2-16mm RSB 3-16mm RSB
3-16mm RSB 2-16mm RSB
RB1 250x300 1@50, 3@75, 6@100, rest@180
2-16mm RSB 3-16mm RSB
4-16mm RSB 2-16mm RSB
RB2 250x300 1@50, 3@75, 6@100, rest@180
2-16mm RSB 4-16mm RSB
DESIGN OF FOOTINGS
REBARS
MARK DIMENSIONS DEPTH THICKNESS REMARK
AsW AsL
F1 1.5m x 1.5m 1.20m 0.30m 20mm @ 150mm 20mm @ 150mm ISOLATED
F2 1.0m x 1.0m 1.20m 0.30m 20mm @ 150mm 20mm @ 150mm ISOLATED
WF1 0.5m x L 0.45m 0.25m 16mm @ 200mm CONTINUOUS

300x400 Column
16-20mmø with 12mm ties
spaced; 2@50mm, 2@100mm
4@120mm, rest @160mm

1.2000 16mmø Rebar


125mm THK CHB Wall
10mmø Horizontal and
Vertical Bars@600mm
on center bothways
0.4500
5-20mmø Rebar 3-16mmø Rebar

0.5000
1.5000
VARIES

L/4 L/2 L/4

12mmø RSB

SCHEDULE OF FLOOR SLABS


AS TRANSVERSE AS LONGITUDINAL
TYPE THICKNESS
BEND BARS TEMP. BARS BEND BARS TEMP. BARS
2-WAY 100mm 12mmø @ 300mm 12mmø @ 300mm 12mmø @ 300mm 12mmø @ 300mm
12mmø Sag Rod
2"x4" C-Purlin
Steel Tile Roofing

Prepainted Steel
Tile Gutter

1/4" THK Marine Plywood


Ceiling on 2"x2" Wood
Wooden Beam Nailers SP. @0.40x0.60 m
on center bothways
75mmø PVC Pipe

1.8000

SCHEDULE OF PURLINS/ SAG ROD/ TIE ROD


DESIGNATION SECTION REMARKS
PURLINS 2"x4" 400mm spacing c.c.
12mmø RSB SAG ROD 12mmø rebars with turn buckles Cross Bracing
TIE ROD 12mmø rebars 1 Rod per bay
1.2000
SCHEDULE OF STAIRS
DESIGNATION THICKNESS BOTTOM REINFORCEMENT DISTRIBUTION REINFORCEMENT
FLIGHT 150mm 16mmø rebars @ 150mm c.c. 12mmø rebars @ 200mm c.c.
LANDING 150mm 16mmø rebars @ 150mm c.c. 12mmø rebars @ 200mm c.c.
0.8000 16mmø RSB
S1
S1
S3
S3

S1 S1
S1 S1

S1 S1

S2 S2
S2 S2

S3 S3
S2 S2

S3 S3

2 2
2 2

1 1

ELECTRIC LAYOUT PLAN


5 5

3 3

4 4

ELECTRIC LAYOUT PLAN


CKT. LOAD DESCRIPTION NUMBER OF SWITCHES VA VOLT AMP OVERCURRENT SIZE OF WIRE SIZE OF
NO. L.O. C.O. ETC. S1 S2 S3 RATING POLE CONDUIT
1 LIGHTNING OUTLET 13 1 1 2 1300 230 5.622 15 AT 2 2-3.5mm² THHN 20mm ø PVC
2 LIGHTNING OUTLET 13 3 2 1 1300 230 5.622 15 AT 2 2-3.5mm² THHN 20mm ø PVC
3 DUPLEX CONVIENIENCE OUTLET 7 2800 230 12.174 20 AT 2 2-3.5mm² THHN 20mm ø PVC
4 DUPLEX CONVIENIENCE OUTLET 9 3600 230 15.652 20 AT 2 2-3.5mm² THHN 20mm ø PVC
5 REFRIGERATOR (1HP) 1 1840 230 8.000 20 AT 2 2-3.5mm² THHN 20mm ø PVC
6 SPARE
7 SPARE
8 SPARE
TOTAL 26 16 1 4 3 3 10840 230 47.070 110 AT 2 2-3.5mm² THHN 20mm ø PVC

DESIGN COMPUTATION
A. COMPUTATION OF SERVICE ENTRANCE B. COMPUTATION OF SERVICE EQUIPMENT
I = [10840 + 25% (2760)] / 230 MAIN C.B. RATING = [10840 + 150%(2760)] / 230
I = 50.130 A MAIN C.B. RATING = 65.130 A

USE 2-30mm THW COPPER WIRE IN 32mm PVC ELECTRICAL PIPE USE 110 AT, 2P, 230V, MOLDED CASE C.B.

1. THE SCOPE OF ELECTRICAL WORKS HEREIN SHALL BE LIMITED ONLY TO THE PLAN, SPECIFICATION AND SPECIAL DRAWING APPROVED AND RELEASED FOR CONSTRUCTION
BY OWNER AND GOVERNMENT AGENCIES. ANY DEVIATION OR REVISION SHALL BE CONSULTED TO THE PROFESSIONAL ELECTRICAL AND DESIGNER PRIOR IMPLEMENTATION.
2. ALL ELECTRICAL WORKS SHALL BE EXECUTED IN ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION OF THE PHILIPPINES ELECTRICAL CODE, RULES AND
REGULATION OF THE LOCALITY AND PERTINENT REQUIREMENTS OF THE LOCALITY POWER UTILITY COMPANY
3. ALL ELECTRICAL WORKS SHALL BE EXECUTED BY EXPERIENCED PERSONNEL UNDER THE DIRECT SUPERVISION OF DULY LICENSED PROFESSIONAL ELECTRICAL ENGINEER,
REGISTERED ENGINEER AND MASTER ELECTRICIAN
4. THE TYPE OF POWER SERVICE TO BE USED SHALL BE 220 V 2 WIRE 1 PHASE, 60HZ
5. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND CONFORM WITH THE PHILIPPINES STANDARD, US UNDER WRITERS LABORATORIES INC. AND OF APPROVED TYPE OF
THE LOCATION AND PURPOSED
6. MINIMUM SIZE OF CONDUCTOR TO BE USED SHALL BE 3.5MM SQ INSULATED TYPE THHN OR THW THERMOPLASTIC, 600V, COPPER WIRE FOR CIRCUIT RUNS AND 0.20 MM
SQ THHN OR THW FOR SWITCH LEG, UNLESS OTHERWISE MATSUSHITA FOR EMT AND RSC PIPES, NELTEX, ATLANTA MOLDEX, FOR THICKWALL
7. ELECTRICAL CONDUIT TRADE SIZE SHALL BE USED A MINIMUM OF 20MM 0 FOR UPVC AND RIGID STEEL (R. G.) CONDUIT IN NO CASES SHALL BE THERE MORE THAN FOUR
QUARTER BENTS IN ANYONE RUN. UNLESS OTHERWISE SPECIFIED MATSUSHITA FOR EMT AND RCS PIPES, NELTEX ATLANTA, MOLDEX, FOR THICK WALL UPVC PIPES AND
MOLDEFLEX FOR UPVC PUPES FLEXIBLE
8. UNLESS OTHERWISE SPECIFIED ALL WRITING DEVICES TO BE USED SHALL BE NATIONAL TOSHIBA KOPEZ, OR TOCINO BRANDS, COLORS OF PLATE COVER SHALL BE
VERIFIED TO THE ENGINEER/ DESIGNER
9. METAL PULL BOXES FOR JUNCTION BOXES SHALL BE PROVIDED WHEREVER REQUIRED ALTHOUGH SUCH BOXES ARE NOT USUALLY INDICATED ON PLANS
10. NO BRANCH CIRCUIT IN WRITING POWER AND LIGHTING SHALL HAVE LOAD MORE THE 80% OF ITS RATING
11. MOUNTING HEIGHT OF DEVICES SHALL BE APPROVED BT ENGINEER IN CHARGE OF SUCH AS FOLLOWS
PANEL BOARD 1.82 M. AFF (ABOVE FIN. LN. TO TOP PANEL)
WALL SWITCH 1.40 M. AFF (TO CENTER OF DEVICE)
RECEPTACLE OUTLET 0.30 M. AFF (TO CENTER OF DEVICE)
RANGE OUTLET 0.60 M. AFF (TO CENTER OF DEVICE)
THE INSTALLER CONTRACTOR SHALL VERIFY AND ORIENT PROPER LOCATION OF SERVICE FOR CONNECTION TO THE POWER SUPPLY.
TO SECONDARY LINE
230V 2-WIRE
SINGLE PHASE 1 0 , 60 HERTZ
230V, AC, 60Hz

CLASS - 230V
M
GE BRAND KWH METER
2 - 8mm THW Cu WIRE
20mm PVC PIPE
40 AT, 2 POLE
Molded Alr Ckt. Breaker SECONDARY RACK
0.5000
SERVICE ENTRANCE CAP
15AT, 2P 15AT, 2P

1 2
20AT, 2P 20AT, 2P
PANEL BOARD
3 4
20AT, 2P KWH METER
5 6

7 8
2.5000
1.8000
1.6000

0.4500

SERVICE ENTRANCE PLAN


F WC
SHO
SHO
WC
F

F F

SHO WC F F WC SHO
RISER RISER RISER RISER

WATER LINE LAYOUT PLAN


DS DS
F WC
CO
FD
FD CO
WC
F

DS
FD DS
DS DS
FD

CO CO
F F

CO RISER
CO FD FD
WC F F WC
CO CO
RISER RISER RISER

PLUMBING LAYOUT PLAN


1.1750 1.2000 1.5000

0.3000
2.0465
0.5000
0.6000
0.5000
1.3782

4.4750

0.3500 0.1500 100mm THK CHB Wall


w/ Cement Plaster Finish

DIGESTION
CHAMBER
LEACHING
CHAMBER
DIGESTION
CHAMBER
150mm THK CHB Wall
w/ Cement Plaster Finish
0.8000
10mmø RSB @every 2
Layers of CHB

1.5500 10mmø Rebar


100MMø PVC PIPE
0.5000
2% SLOPE 2% SLOPE

0.3000
0.4500

DETAIL OF SEPTIC VAULT AND CATCH VASIN


3.0500
2.7000

3.1000 3.1000

0.2000

0.2000