FLOOR PLAN
0.7000 0.6000
1.0000 1.2000 2.0000 0.4000 0.6000 1.9000
0.4000
1.2000 1.2000
2.1000 2.1000 2.1000 2.1000
1.7000
0.9000 0.9000
D D D W W W W W
1 2 3 1 2 3 4 5
Type Panel Swing Door Type Panel Swing Door Type Flush Swing Door Type Sliding Window Type Sliding Window Type Awning Window Type Fixed Window Type Sliding Door
Materials Wood Materials Wood Materials PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC Frame Aluminum or PVC
Frame Wood Frame Wood Frame PVC Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass Panel 6 mm THK Clear Glass
Required 2 sets Required 6 sets Required 4 SETS Required 8 SETS Required 2 SETS Required 3 SETS Required 2 SETS Required 2 SETS
B1 RB1 RB1
WF1 WF1 B1
B1 B1 RB1 RB1
F1C1 F1C1 F1C1
WF1 WF1
WF1 WF1 B1 B2 B1 RB1 RB2 RB1
RB1 RB1
F1C1 F1C1
B1 B1
F1C1
B3 B3 B3 B3
B3 B3
F2C1 F2C1 F2C1 F2C1
SCHEDULE OF BEAMS
NUMBER OF REINFORCEMENT STIRRUPS SPACING
MARK DIMENSIONS
@SUPPORT @MIDSPAN 10mm ø REBARS
6-16mm RSB 2-16mm RSB
B1 250x400 1@50, 3@75, 6@100, rest@180
3-16mm RSB 5-16mm RSB
8-16mm RSB 4-16mm RSB
B2 250x400 1@50, 3@75, 6@100, rest@180
4-16mm RSB 8-16mm RSB
3-16mm RSB 2-16mm RSB
B3 250x250 1@50, 3@75, 6@100, rest@180
2-16mm RSB 3-16mm RSB
3-16mm RSB 2-16mm RSB
RB1 250x300 1@50, 3@75, 6@100, rest@180
2-16mm RSB 3-16mm RSB
4-16mm RSB 2-16mm RSB
RB2 250x300 1@50, 3@75, 6@100, rest@180
2-16mm RSB 4-16mm RSB
DESIGN OF FOOTINGS
REBARS
MARK DIMENSIONS DEPTH THICKNESS REMARK
AsW AsL
F1 1.5m x 1.5m 1.20m 0.30m 20mm @ 150mm 20mm @ 150mm ISOLATED
F2 1.0m x 1.0m 1.20m 0.30m 20mm @ 150mm 20mm @ 150mm ISOLATED
WF1 0.5m x L 0.45m 0.25m 16mm @ 200mm CONTINUOUS
300x400 Column
16-20mmø with 12mm ties
spaced; 2@50mm, 2@100mm
4@120mm, rest @160mm
0.5000
1.5000
VARIES
12mmø RSB
Prepainted Steel
Tile Gutter
1.8000
S1 S1
S1 S1
S1 S1
S2 S2
S2 S2
S3 S3
S2 S2
S3 S3
2 2
2 2
1 1
3 3
4 4
DESIGN COMPUTATION
A. COMPUTATION OF SERVICE ENTRANCE B. COMPUTATION OF SERVICE EQUIPMENT
I = [10840 + 25% (2760)] / 230 MAIN C.B. RATING = [10840 + 150%(2760)] / 230
I = 50.130 A MAIN C.B. RATING = 65.130 A
USE 2-30mm THW COPPER WIRE IN 32mm PVC ELECTRICAL PIPE USE 110 AT, 2P, 230V, MOLDED CASE C.B.
1. THE SCOPE OF ELECTRICAL WORKS HEREIN SHALL BE LIMITED ONLY TO THE PLAN, SPECIFICATION AND SPECIAL DRAWING APPROVED AND RELEASED FOR CONSTRUCTION
BY OWNER AND GOVERNMENT AGENCIES. ANY DEVIATION OR REVISION SHALL BE CONSULTED TO THE PROFESSIONAL ELECTRICAL AND DESIGNER PRIOR IMPLEMENTATION.
2. ALL ELECTRICAL WORKS SHALL BE EXECUTED IN ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION OF THE PHILIPPINES ELECTRICAL CODE, RULES AND
REGULATION OF THE LOCALITY AND PERTINENT REQUIREMENTS OF THE LOCALITY POWER UTILITY COMPANY
3. ALL ELECTRICAL WORKS SHALL BE EXECUTED BY EXPERIENCED PERSONNEL UNDER THE DIRECT SUPERVISION OF DULY LICENSED PROFESSIONAL ELECTRICAL ENGINEER,
REGISTERED ENGINEER AND MASTER ELECTRICIAN
4. THE TYPE OF POWER SERVICE TO BE USED SHALL BE 220 V 2 WIRE 1 PHASE, 60HZ
5. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND CONFORM WITH THE PHILIPPINES STANDARD, US UNDER WRITERS LABORATORIES INC. AND OF APPROVED TYPE OF
THE LOCATION AND PURPOSED
6. MINIMUM SIZE OF CONDUCTOR TO BE USED SHALL BE 3.5MM SQ INSULATED TYPE THHN OR THW THERMOPLASTIC, 600V, COPPER WIRE FOR CIRCUIT RUNS AND 0.20 MM
SQ THHN OR THW FOR SWITCH LEG, UNLESS OTHERWISE MATSUSHITA FOR EMT AND RSC PIPES, NELTEX, ATLANTA MOLDEX, FOR THICKWALL
7. ELECTRICAL CONDUIT TRADE SIZE SHALL BE USED A MINIMUM OF 20MM 0 FOR UPVC AND RIGID STEEL (R. G.) CONDUIT IN NO CASES SHALL BE THERE MORE THAN FOUR
QUARTER BENTS IN ANYONE RUN. UNLESS OTHERWISE SPECIFIED MATSUSHITA FOR EMT AND RCS PIPES, NELTEX ATLANTA, MOLDEX, FOR THICK WALL UPVC PIPES AND
MOLDEFLEX FOR UPVC PUPES FLEXIBLE
8. UNLESS OTHERWISE SPECIFIED ALL WRITING DEVICES TO BE USED SHALL BE NATIONAL TOSHIBA KOPEZ, OR TOCINO BRANDS, COLORS OF PLATE COVER SHALL BE
VERIFIED TO THE ENGINEER/ DESIGNER
9. METAL PULL BOXES FOR JUNCTION BOXES SHALL BE PROVIDED WHEREVER REQUIRED ALTHOUGH SUCH BOXES ARE NOT USUALLY INDICATED ON PLANS
10. NO BRANCH CIRCUIT IN WRITING POWER AND LIGHTING SHALL HAVE LOAD MORE THE 80% OF ITS RATING
11. MOUNTING HEIGHT OF DEVICES SHALL BE APPROVED BT ENGINEER IN CHARGE OF SUCH AS FOLLOWS
PANEL BOARD 1.82 M. AFF (ABOVE FIN. LN. TO TOP PANEL)
WALL SWITCH 1.40 M. AFF (TO CENTER OF DEVICE)
RECEPTACLE OUTLET 0.30 M. AFF (TO CENTER OF DEVICE)
RANGE OUTLET 0.60 M. AFF (TO CENTER OF DEVICE)
THE INSTALLER CONTRACTOR SHALL VERIFY AND ORIENT PROPER LOCATION OF SERVICE FOR CONNECTION TO THE POWER SUPPLY.
TO SECONDARY LINE
230V 2-WIRE
SINGLE PHASE 1 0 , 60 HERTZ
230V, AC, 60Hz
CLASS - 230V
M
GE BRAND KWH METER
2 - 8mm THW Cu WIRE
20mm PVC PIPE
40 AT, 2 POLE
Molded Alr Ckt. Breaker SECONDARY RACK
0.5000
SERVICE ENTRANCE CAP
15AT, 2P 15AT, 2P
1 2
20AT, 2P 20AT, 2P
PANEL BOARD
3 4
20AT, 2P KWH METER
5 6
7 8
2.5000
1.8000
1.6000
0.4500
F F
SHO WC F F WC SHO
RISER RISER RISER RISER
DS
FD DS
DS DS
FD
CO CO
F F
CO RISER
CO FD FD
WC F F WC
CO CO
RISER RISER RISER
0.3000
2.0465
0.5000
0.6000
0.5000
1.3782
4.4750
DIGESTION
CHAMBER
LEACHING
CHAMBER
DIGESTION
CHAMBER
150mm THK CHB Wall
w/ Cement Plaster Finish
0.8000
10mmø RSB @every 2
Layers of CHB
0.3000
0.4500
3.1000 3.1000
0.2000
0.2000