Diagnosis - Fault memory

Preceding work: Testing, adjusting engine (07-1100)

Note regarding fault memory Note regarding self-adaptation of mixture formation


The PMS control unit (N3/6) features a fault memory. Faults are recognized and On vehicles fitted with catalytic converter, the lambda control determines the
stored according to the following categories: injection time so exactly that the fuel/air ratio is always lambda 1 in all operating
states (corresponds to 14.7 kg air to 1 kg fuel).
a Fault exists constantly If faults occur as a result of:
a Fault exists for longer than 3 seconds
a Loose contact faults which have occurred 5 times during a journey a ingress of air
a wear or coking of fuel injection valves
The fault memory is erased if the supply voltage for the PMS control unit is
a wear to engine
interrupted, as e. g. when the battery is disconnected or control unit coupling "1"
a fault in intake manifold pressure detection
vehicle side is unplugged (see à 11/2, Recognition of mechanical end stop of
a defective diaphragm pressure regulator or diaphragm pressure damper
closed throttle valve).
a defective regeneration
Faults which no longer occur are erased again automatically after not more than 19 the PMS control unit automatically performs a correction of the mixture formation.
journeys). A journey has been performed if: The correction parameters are constantly calculated and permanently stored. Self-
adaptation is performed at idling speed and at part load. The correction in each
a road speed >4 km/h case is not more than 25 % toward rich or lean mixture. Following repair work, the
a engine speed >700/min PMS control unit once again performs automatic self-adaptation after about 10
a engine switched off for 3 minutes. journeys. After rectifying the stated faults, the self-adaptation must be reset (see
Resetting and re-activating memory of PMS control unit à 11/3).
The stored faults can be read and the test coupling for diagnosis (X11/4) with
ignition "ON" or with "engine running".

Diagnosis - Fault memory

Notes regarding automatic recognition of vehicle version Note regarding automatic recognition of the mechanical end stop of the
When the vehicle is used for the first time, the PMS control unit recognizes the closed throttle valve
following versions and stores them: The mechanical end stop of the closed throttle valve is detected at idling speed by
the idle speed control actuator and stored in the PMS control unit.
a KAT/without KAT After replacing the PMS control unit or the actuator or after disconnecting and
a Manual/automatic transmission connecting the battery, the mechanical end stop of the throttle valve must be re-
detected and stored (see Resetting and re-activating memory of the PMS control
After replacing the PMS control unit or after installing the PMS control unit from unit à 11/5).
another vehicle for test purposes, the recognition must be re-activated (see
Resetting and re-activating memory of the PMS control unit à 11/5).

Reprograming control unit

Preconditionts for programing:


a Battery voltage í min. 11 V
a Road speed signal íV=0
a Engine speed signal ín=0
a Drive position í P/N = 1
a Idle speed contact closed í LLK = 1
(Important: Vehicle must not be moved during programing.)
a Start off vehicle í V => 5 km/h
(Transmission variant is not programed until vehicle moves off.)

Diagnosis - Fault memory

Авторское право DaimlerChrysler AG 24.08.2005 CD-Ausgabe G/10/04 .Эта распечатка из WIS в службе учёта и внесения изменений не регистрируется. Стр. 1
Note on HHT a Actual value of intake manifold absolute pressure
a Troubleshooting with HHT If there is no intake manifold absolute pressure at the PEC control module
Fault memory: Select current faults (N3/6) or a defect in the pressure sensor in the N3/6 the system switches over
If the current condition changes, e.g. due to a loose plug connection, the immediately from the current actual value to a substitute value which is very
change is signalled visually and audibly so that troubleshooting can be carried close to the actual value. Consequently, a fault cannot be clearly recognized. It
out directly with the HHT. is only possible to read the fault from the fault memory.
a Loose contacts
Loose contacts are stored if they occur several times over a particular period of a Actual engine speed value
time. They can therefore only occur as stored faults and never as current faults. For the engine speed, the specified idle speed value calculated by the control
module appears on the left of the HHT display, and the actual speed appears
a Specified values on the right. Both values should only differ slightly. The permissible tolerances
All specified values relating to the actual values displayed in the HHT are given have not yet been specified.
in the Diagnosis Manual Engine Volume 1 Chapter A.

a Actual values of engine coolant temperature/intake air


In the event of an open-circuit or short-circuit, the system switches over
immediately from the current actual value to a substitute value which is very
close to the actual value. Consequently, a fault cannot be clearly recognized. It
is only possible to read the fault from the fault memory.

Diagnosis - Fault memory

Notes on immobilizer

Stage 1 Stage 2a
a On model 124 with manual transmission an immobilizer is fitted as standard a On model 124.060 as of 3/96 the IR DAS control module (N54/1) is installed.
as of 03/94 which acts on the pressurized engine control (PEC). The fuel pump Activation is by the infrared remote control module. The PEC control module
relay and terminal 15 to the PEC control module are interrupted by the immobilizer. renders the injection system inoperative once the drive authorization system is
activated. This drive authorization system can only be activated and de-activated
by the RCL remote control.
Only terminal 50 to the starter is interruped on all other models. At the start of the Unlocking and locking the vehicle with the mechanical key has no effect on the
test it must be ensured that the immobilizing functions of the immobilizer are drive authorization system.
isolated.
Notes on drive authorization system
Replacing the PEC control module or the RCL control module on a trial basis with
parts from another vehicle is therefore not possible.
Stage 2
a A drive authorization system which intervenes in the PEC control module is
fitted as standard on vehicles as of 1/95 (except model 124).

Diagnosis code: Bosch control module as of 63/00


Siemens control module as of 67/00

The immobilizer is activated by the RCL control module to the PEC control module.

Diagnosis - Fault memory

Preconditions for test with pulse counter Erasing fault memory


a Connect pulse counter to the test coupling for diagnosis (X11/4) according a) Press start button 2 -4 s ("fault code" appears).
to the connection diagram. b) Press start button 6 - 8 s; the fault displayed previously is cancelled.
Reading fault memory c) Repeat points a) and b) until fault code "I" appears (no more faults appear).
a) Ignition: ON
b) Press start button for 2 - 4 seconds.
c) Read off fault code and note. Resetting and re-activating memory of the PMS control unit
d) Once again press start button. a) Erase fault memory.
e) Read off fault code.
Repeat points d) and e) until the first fault code reappears. b) After fault code "I" appears, press the start button 6 - 8 s.
c) Switch off ignition and wait at least 2 seconds.
d) Switch on ignition and wait at least 10 seconds before starting engine.

Special tools

Diagnosis - Fault memory

Авторское право DaimlerChrysler AG 24.08.2005 CD-Ausgabe G/10/04 .Эта распечатка из WIS в службе учёта и внесения изменений не регистрируется. Стр. 2
Commercially available tools and testers, MB testers (see Workshop Equipment Manual)
Designation e.g. make, order no.
Hand-Held Tester Mercedes-Benz AG
D-70322 Stuttgart
VP/PSD2
6511 00 01 99
Test cable (Multiplexer) Mercedes-Benz AG
D-70322 Stuttgart
VP/PSD2
6511 00 40 99
Test cable (HHT) for test coupling (X11/4, 8- or 16-pin) Mercedes-Benz AG
D-70322 Stuttgart
VP/PSD2
6511 00 50 99

Diagnosis - Fault memory

Connection diagram of pulse counter/Hand-Held Tester


Model 124
Pulse counter
Black cable, terminal 31 (ground) socket 1
Red cable terminal 15 (ignition) socket 16
Yellow cable (diagnosis, PEC) socket 8

Hand-Held Tester
Black cable, terminal 31 (ground) socket 1
White cable terminal 15 (ignition) socket 16
Red cable terminal 30 battery + or
X4/10
Yellow cable (diagnosis, PEC) socket 8

Fig. 1
013 Pulse counter
087 Hand-Held Tester
X11/4 Data link connector (DTC readout) (16-pin)

P07-5730-57A

Diagnosis - Fault memory

Connecting diagram for pulse counter/Hand-Held Tester


Model 202

Pulse counter
Black cable, terminal 31 (ground) socket 1
Red cable, terminal 30 (battery +) socket 3
Yellow cable (diagnosis, PEC) socket 4

Hand-Held Tester
Connect with test cable (094). Read out, erase fault memory
(refer to operating instructions for Hand-Held Tester)

Fig. 2
013 Pulse counter
075 Pulse counter adapter
087 Hand-Held Tester
094 Test cable (multiplexer)
X11/4 Data link connector (DTC readout) (38-pin)

P07-5925-57

Diagnosis - Fault memory

Fault code Possible cause Remedy/Test step 1)

N A
I - No fault recognized in system -
Авторское право DaimlerChrysler AG 24.08.2005 CD-Ausgabe G/10/04 .Эта распечатка из WIS в службе учёта и внесения изменений не регистрируется. Стр. 3
2 002-005 PMS coolant temperature sensor (B11/3) à 23 í 5.0
3 006-008 Intake air temperature sensor (B17) à 23 í 6.0
4 009-0I0 Intake manifold sensor in PMS control unit (N3/6) à 23 í 3.0
5 0II-0I2 Idle speed contact at idle speed control actuator (M16/6s1) à 23 í 8.0
5 0II-0I2 Idle speed contact at idle speed control actuator (M16/6s1) à 25 í 4.0
6 0I3-0I5 Throttle valve actual value potentiometer in idle speed control actuator (M16/6r1) à 25 í 1.0, 2.0
7 0I6-0I8 Actual value potentiometer drive in idle speed control actuator (M16/6r2) à 25 í 3.0
8 0I9-02I Fault in idle speed control system (control switches to emergency operation mode) Throttle valve sticky (possibly only
occasionally).
Reset PMS control unit memory (N3/6)
and reactivate, see à 11/5
If fault is indicated again:
Idle speed control actuator (M16/6)
9 022-024 Oxygen sensor (G3/2) à 23 í 10.0
I0 - not assigned -

1) Pay attention to preconditions for test, see à 22

Diagnosis - Fault memory

Fault code Possible cause Remedy/Test step 1)

N A
II 025-027 Oxygen sensor heater for oxygen sensor (G3/4) à 23 í 11.0
I2 - not assigned -
I3 028-029 Lambda control at rich or lean stop Unmetered air, fuel injection valves,
diaphragm pressure regulator, engine
wear, fuel evaporation control system
I4 030-03I Fuel injection valve group, cylinder 1 (Y62y1) + cylinder 4 (Y62y4) à 23 í 12.0
I5 032-033 Fuel injection valve group, cylinder 2 (Y62y2) + cylinder 3 (Y62y3) à 23 í 13.0
I6-19 - not assigned -
20 034-037 Self-adaptation at rich or lean stop Unmetered air, fuel injection valves,
diaphragm pressure regulator, engine
wear, fuel evaporation control system
2I 038-040 Ignition output stage or ignition coil (T1/1) for cylinders 1 + 4 à 24 í 6.0, 8.0, 10.0
22 04I-043 Ignition output stage or ignition coil (T1/2) for cylinders 2 + 3 à 24 í 7.0, 9.0, 11.0
23 - not assigned -
24 044-046 Crankshaft position sensor (L5) or magnet for position sensor on flywheel segment à 24 í 5.0
25 - not assigned -

1) Pay attention to preconditions for test, see à 22

Diagnosis - Fault memory

Fault code Possible cause Remedy/Test step 1)

N A
26 047-048 PMS resistance trimming plug (R16/7) à 23 í 14.0
27 049-050 TN speed signal (output) from PMS control unit (N3/6) à 23 í 7.0
28 05 I-052 Road speed signal from ABS control unit (N30) à 23 í 16.0
29 053-054 Model 124 with KAT up to 06/93 only à 23 í 9.0
Partial intake manifold preheating relay (K3/1)
30 055-056 Fuel pumps relay (K27) à 23 í 4.0
3I 057-058 Without KAT à 23 í 15.0
CO potentiometer (R33)
32-35 - not assigned -
36 059-060 Regeneration switchover valve (Y58/1) à 23 í 24.0
06I Short-term self-adaptation idle/partial load Short-term malfunction in mixture
preparation
37 062 KAT with AG only à 23 í 17.0
Shift point retard switchover valve (Y3/3)
38-48 - not assigned -

1) Pay attention to preconditions for test, see à 22

Diagnosis - Fault memory

Fault code Possible cause Remedy/Test step 1)

N A
49 063 Voltage supply on PMS control unit (N3/6) not logical/voltage too low à 23 í 1.0
à 23 í 2.0
064 Immobilizer signal from IFZ control unit: open circuit/short circuit to positive à 23 í 25.0

Авторское право DaimlerChrysler AG 24.08.2005 CD-Ausgabe G/10/04 .Эта распечатка из WIS в службе учёта и внесения изменений не регистрируется. Стр. 4
065 Immobilizer signal from IFZ control unit: open circuit/short circuit to negative à 23 í 25.0
066 Attempt made to start engine when IFZ locking system locked Malfunction
Erase fault memory à 11/5
067 Immobilizer signal from IFZ control unit implausible Incorrect IFZ control unit
Replace IFZ control unit (N54)

1) Pay attention to preconditions for test, see à 22