Point of ● Run CPU ● DI120-150

TCD - 211 Other E/L Fault Application


Detection ○ Speed CPU ● DI180-420

[Actions to take]
[Meaning] Other E/L is failed.

1. Check the failed E/L

[Explanation] See if there are any failed E/Ls in the group.

An error is detected when ALIVE signal is not received from an E/L included in Check the value of variable(Balive_Member) ADDRESS
NPLEX(group for a certain period. 0x81D with ANNOUNCIATOR.
Here, an E/L whose bit is not set is judged to be a failed E/L.
All E/Ls in NPLEX group can diagnose the other E/Ls for faults by exchanging
ALIVE signal one another which are predetermined.
For example,
If ALIVE signal is not received regularly from a E/L, that E/L is judged to be failed. If 2 E/L is failed among 3 ones,
ADDR 0x81D2 value is 0x05.
But, an E/L that has never run does not affect failure detection though it belongs to If 2 and 3 E/Ls are failed among 3 ones,
NPLEX group. the value is 0x01.

2. If there’s no E/L failed,


verify that the communication line is well connected.

[Symptoms] If there’s no error found in all E/Ls and all E/Ls are masters,
the error may be from communication line disconnection.
An E/L failed is excepted from allocation.
Note) Master E/L check
If there’s no failed E/L found, bad signal output may occur
Check variable(I_am)ADDRESS 0x8000
on account of bad communication.
with ANNOUNCIATOR.
1) Only some E/Ls do hall call service, or
2) Master/slave selection is repeated, or
0xff : Master E/L
3) One or more E/L do back-up operation.
0x00: Slave E/L
0xf0: Master/Slave