LIMIT STATE OF FLEXURE

Limit state of concrete , ecu2 0.0035 0.0035 0.0035 0.0035 0.0035 0.0035
Limit state of steel εuk 0.0350 0.0350 0.0350 0.0350 0.0350 0.0350
Design Limit state of steel εud
=0.90 euk 0.0315 0.0315 0.0315 0.0315 0.0315 0.0315
fck [Mpa] 40 40 40 40 40 40

α 0.67 0.67 0.67 0.67 0.67 0.67


ym 1.50 1.50 1.50 1.50 1.50 1.50
f cd = a*fck/ym [Mpa] 17.87 17.87 17.87 17.87 17.87 17.87
f syk 500 500 500 500 500 500
ys 1.15 1.15 1.15 1.15 1.15 1.15
Comp flange Width [mm] 1000 1000 1000 1000 1000 1000

Depth of Sec D [mm] 300 600 600 600 300 300


Effective Depth, d [mm] 217 517 515 515 219 217
Ceff [mm] 83 83 85 85 81 83
Strain in steel reinforcement 0.0102 0.0291 0.0069 0.0069 0.0088 0.0102
Strain limit < eud OK OK OK OK OK OK
Stress in steel 435 435 435 435 435 435
Ast [mm2] 1827 1827 5709 5709 2055 1827
Ast_min [mm2]- maximum of (.26fctm/fy*bd or .0013 bd ) ( as per 16.5.1.1 of IRC 112 2011)
(.26f ctm /f y *bd 338.52 806.52 803.4 803.4 341.64 338.52
.0013 bd 282.1 672.1 669.5 669.5 284.7 282.1
Ast_min [mm2] req. 338.52 806.52 803.4 803.4 341.64 338.52
Check < 1 0.19 0.44 0.14 0.14 0.17 0.19
STATUS Safe Safe Safe Safe Safe Safe
Fc [N] =( 0.80.x.fcd.B) 794308 794308 2482213 2482213 893597 794308
Ft [N] = 794308 794308 2482213 2482213 893597 794308
Fc-Ft 0.00 0.00 0.00 0.00 0.00 0.00
NA, x [mm] 55.6 55.6 173.7 173.7 62.5 55.6
Mu [kN-m] 154.71 393.00 1105.91 1105.91 173.35 154.71
M/Mu <1 0.01 0.41 0.70 0.92 0.13 0.54