Professional Documents
Culture Documents
9000SRM1112 - Memory Integrity Fault (MEMORY INTEGRITY FAULT)
9000SRM1112 - Memory Integrity Fault (MEMORY INTEGRITY FAULT)
9000SRM1112 - Memory Integrity Fault (MEMORY INTEGRITY FAULT)
9030-1
9030-2
Diagnostic Trouble Codes
Group 20
Diagnostic Trouble Codes
524268-12
524263-1
524262-14
524262-12
524236-14
522215-14
522215-12
WARNING
For DTC 524263-1 – DO NOT REPLACE VSM for this fault code. Complete Component Operational Check
and Clear VSM Fault Log.
NOTE: When updating VSM Application Software from Ver 4.x to 5.x, DTC 524262-14 will appear. Do the Compo-
nent Operational Check when the update is complete and Clear VSM Fault Log
NOTE: When updating VSM Application Software from Ver 5.1 to 5.x, DTC 524262-14 may appear. Do the Compo-
nent Operational Check when the update is complete and Clear VSM Fault Log
1. Turn power to OFF for no less than 30 seconds, and then to ON to clear displayed DTC.
Does reported DTC reoccur?
YES: Go to Step 1.
NO: Problem not verified. Resume operation.
2. Conduct a quick visual inspection of all connectors/wiring associated with the displayed fault code.
Are any of the connectors/wiring damaged?
YES: Repair/replace connector or wiring associated with faults found. Refer to the appropriate Electrical Sys-
tem SRM. Repeat Step 1.
NO: Go to Cause A.
Check the Service Manual section in Hypass Online for possible updates and check pertinent Grams
9030-20-1
Diagnostic Trouble Codes
DIAGRAMS
Check the Service Manual section in Hypass Online for possible updates and check pertinent Grams
9030-20-2
Diagnostic Trouble Codes
For additional information on the VSM, refer to the appropriate Electrical System SRM.
END FAULT
Check the Service Manual section in Hypass Online for possible updates and check pertinent Grams
9030-20-3