Project name Pozos L2


Project address Peru
Reference Peru
Client name Ayesa
Revision GCM_01

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Type Model Name Qty Description
Outdoor unit RXQ10AYM 3 Cooling only VRV A (18,20HP single module)
RXQ8AYM 4 Cooling only VRV A (18,20HP single module)
Indoor unit FXAQ40AVM 2 VRV A(AVM) - Unidad montada en pared
FXAQ50AVM 2 VRV A(AVM) - Unidad montada en pared
FXAQ63AVM 4 VRV A(AVM) - Unidad montada en pared
FXHQ100MA 4 VRV H - Unidad suspendida del techo
VE
FXHQ63MAV 1 VRV H - Unidad suspendida del techo
E
FXMQ100PAV 3 VRV M-PA - Unidad de conducto montada en el techo
E
FXMQ140PAV 3 VRV M-PA - Unidad de conducto montada en el techo
E
Branch unit KHRP26A22T 5 Refnet branch piping kit
KHRP26A33T 7 Refnet branch piping kit
Option or add-on BRC1E62 19 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 30.0kg Extra refrigerant charge
Copper pipe Piping ø ¼" 56.0m Copper pipe
Piping ø ⅜" 378.7m Copper pipe
Piping ø ½" 56.0m Copper pipe
Piping ø ⅝" 115.2m Copper pipe
Piping ø ¾" 159.8m Copper pipe
Piping ø ⅞" 103.7m Copper pipe

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. /
RH)
Rq TC Required total cooling capacity
Max Available total cooling capacity
TC
Rq SC Required sensible cooling capacity
Max Available sensible cooling capacity
SC
Tevap Evaporating temperature of indoor unit coil
Tdis C Indoor unit discharge air temperature in cooling
Airflo Supplied airflow
w
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHx WidthxHeightxDepth
D
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
2
2.2. PV01 - RXQ10AYM
Capacity data at conditions and connection ratio (116%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXMQ140PAV 32.0 / 15.9 16.8 10.8 11.6 Auto 19.7 1624
E 50%
UI3 FXAQ50AVM 32.0 / 5.4 5.9 3.7 3.8 Auto 19.7 530
50%
UI2 FXHQ100MA 25.0 / 9.5 11.0 6.3 8.0 Auto 9.4 883
VE 50%

Required cooling capacity towards the outdoor unit: 30.9kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 43-46 220V 3.4 1400×300×70 46
1ph 0
UI3 35.5-41 220V 0.7 1050×290×26 15
1ph 9
UI2 37-45 220V 1.3 1400×195×68 33
1ph 0

Outdoor unit placed 13.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
3
2.3. PV02 - RXQ10AYM
Capacity data at conditions and connection ratio (112%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXMQ140PA 32.0 / 13.8 16.8 10.1 11.6 Auto 19.7 1624
VE 50%
UI3 FXAQ40AVM 32.0 / 4.4 4.7 3.0 3.1 Auto 19.5 431
50%
UI2 FXMQ100PA 25.0 / 9.1 11.0 6.8 8.6 Auto 11.9 1130
VE 50%

Required cooling capacity towards the outdoor unit: 27.3kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 43-46 220V 3.4 1400×300×70 46
1ph 0
UI3 33.5-37 220V 0.7 1050×290×26 15
1ph 9
UI2 39-43 220V 2.9 1400×300×70 45
1ph 0

Outdoor unit placed 13.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
4
2.4. PV03 - RXQ8AYM
Capacity data at conditions and connection ratio (121%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXMQ140PA 32.0 / 13.8 16.8 10.1 11.6 Auto 19.7 1624
VE 50%
UI3 FXAQ40AVM 32.0 / 3.7 4.7 2.8 3.1 Auto 19.5 431
50%
UI2 FXHQ63MAV 25.0 / 6.5 7.0 4.7 5.2 Auto 10.4 618
E 50%

Required cooling capacity towards the outdoor unit: 24.0kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 43-46 220V 3.4 1400×300×70 46
1ph 0
UI3 33.5-37 220V 0.7 1050×290×26 15
1ph 9
UI2 34-39 220V 0.9 1160×195×68 28
1ph 0

Outdoor unit placed 12.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
5
2.5. PV04-1 - RXQ10AYM
Capacity data at conditions and connection ratio (105%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXMQ100PAV 32.0 / 11.0 11.8 7.6 8.1 Auto 19.7 1130
E 50%
UI2 FXHQ100MA 25.0 / 8.7 11.0 5.9 8.0 Auto 9.4 883
VE 50%
UI3 FXAQ63AVM 32.0 / 7.3 7.5 4.7 4.7 Auto 19.9 671
50%

Required cooling capacity towards the outdoor unit: 27.0kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 39-43 220V 2.9 1400×300×70 45
1ph 0
UI2 37-45 220V 1.3 1400×195×68 33
1ph 0
UI3 38.5-46.5 220V 0.7 1050×290×26 15
1ph 9

Outdoor unit placed 14.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
6
2.6. PV05-1 - RXQ8AYM
Capacity data at conditions and connection ratio (106%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXHQ100MA 32.0 / 11.8 11.8 6.9 7.4 Auto 17.5 883
VE 50%
UI2 FXAQ50AVM 25.0 / 4.8 5.5 3.6 4.3 Auto 11.0 530
50%
UI3 FXAQ63AVM 32.0 / 7.1 7.5 4.7 4.7 Auto 19.9 671
50%

Required cooling capacity towards the outdoor unit: 23.8kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 37-45 220V 1.3 1400×195×68 33
1ph 0
UI2 35.5-41 220V 0.7 1050×290×26 15
1ph 9
UI3 38.5-46.5 220V 0.7 1050×290×26 15
1ph 9

Outdoor unit placed 11.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
7
2.7. PV04-2 - RXQ8AYM
Capacity data at conditions and connection ratio (81%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXMQ100PA 32.0 / 11.0 11.8 7.6 8.1 Auto 19.7 1130
VE 50%
UI3 FXAQ63AVM 32.0 / 7.3 7.5 4.7 4.7 Auto 19.9 671
50%

Required cooling capacity towards the outdoor unit: 18.3kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 39-43 220V 2.9 1400×300×70 45
1ph 0
UI3 38.5-46.5 220V 0.7 1050×290×26 15
1ph 9

Outdoor unit placed 13.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
8
2.8. PV05-2 - RXQ8AYM
Capacity data at conditions and connection ratio (81%) as entered
Nam FCU Tmp C Rq Max Rq Max Teva Tdis Airflo
e TC TC SC SC p C w
°C kW kW kW kW °C °C cfm
UI1 FXHQ100MA 32.0 / 11.8 11.8 6.9 7.4 Auto 17.5 883
VE 50%
UI3 FXAQ63AVM 32.0 / 7.1 7.5 4.7 4.7 Auto 19.9 671
50%

Required cooling capacity towards the outdoor unit: 19.0kW.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest temperature in
case of heating mode), assuming the indoor unit is running at full load at the given indoor temperature design conditions. In
practice the discharge temperature will modulate based on actual capacity requirements and during defrost mode (heating
mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal
comfort level.

Nam Sound PS MC WxHxD Wgh


e A t
dBA A mm kg
UI1 37-45 220V 1.3 1400×195×68 33
1ph 0
UI3 38.5-46.5 220V 0.7 1050×290×26 15
1ph 9

Outdoor unit placed 13.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
9
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / RH)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Standard factory refrigerant charge (5m actual piping length)
Refr
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHx WidthxHeightxDepth
D
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
10
3.2. Outdoor Details
Name Model Comb Tmp CC Rq Tmp H Rq
C CC H C HC
% °C kW kW °C k kW
W
PV01 RXQ10AY ▼ 116 29.0 27.6 (-10.9%) 30.9
M
PV02 RXQ10AY 112 29.0 27.5 27.3
M
PV03 RXQ8AY ▼ 121 29.0 22.3 (-6.9%) 24.0
M
PV04- RXQ10AY 105 29.0 27.8 27.0
1 M
PV05- RXQ8AY ▼ 106 29.0 23.2 (-2.5%) 23.8
1 M
PV04- RXQ8AY 81 29.0 22.2 18.3
2 M
PV05- RXQ8AY 81 29.0 23.2 19.0
2 M
Name Model Pipin Refrigerant
g
m Type Bse Refr Ex Refr
kg kg
PV01 RXQ10AY 67.4 R410 6.7 5.8
M A
PV02 RXQ10AY 64.7 R410 6.7 5.6
M A
PV03 RXQ8AY 62.0 R410 5.9 5.2
M A
PV04- RXQ10AY 51.3 R410 6.7 4.2
1 M A
PV05- RXQ8AY 34.1 R410 5.9 3.4
1 M A
PV04- RXQ8AY 53.7 R410 5.9 3.4
2 M A
PV05- RXQ8AY 33.9 R410 5.9 2.4
2 M A
Name Model PS MCA WxHxD Wght
A mm kg
PV01 RXQ10AY 380V 21.2 930×1657×76 185
M 3ph 5
PV02 RXQ10AY 380V 21.2 930×1657×76 185
M 3ph 5
PV03 RXQ8AY 400V 16.1 930×1657×76 175
M 3ph 5
PV04- RXQ10AY 380V 21.2 930×1657×76 185
1 M 3ph 5
PV05- RXQ8AY 400V 16.1 930×1657×76 175
1 M 3ph 5
PV04- RXQ8AY 400V 16.1 930×1657×76 175
2 M 3ph 5
PV05- RXQ8AY 400V 16.1 930×1657×76 175
2 M 3ph 5

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
11
3.2.1. PV01 - RXQ10AYM
Model Type Model Name Qty Description
Outdoor unit RXQ10AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ50AVM 1 VRV A(AVM) - Unidad montada en pared
FXHQ100MA 1 VRV H - Unidad suspendida del techo
VE
FXMQ140PAV 1 VRV M-PA - Unidad de conducto montada en el techo
E
Branch unit KHRP26A22T 1 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
Option or add-on BRC1E62 3 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 5.8kg Extra refrigerant charge
Copper pipe Piping ø ¼" 18.1m Copper pipe
Piping ø ⅜" 68.0m Copper pipe
Piping ø ½" 18.1m Copper pipe
Piping ø ⅝" 19.7m Copper pipe
Piping ø ¾" 13.1m Copper pipe
Piping ø ⅞" 35.2m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 6.7kg


Extra refrigerant charge = 68.0m(ø⅜") × 0.057 + 18.1m(ø¼") × 0.022 + A + B = 5.8kg
A [ CR 116%, actual length 66.4m ] = 1.5kg
B [ 10HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
12
3.2.2. PV02 - RXQ10AYM
Model Type Model Name Qty Description
Outdoor unit RXQ10AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ40AVM 1 VRV A(AVM) - Unidad montada en pared
FXMQ100PA 1 VRV M-PA - Unidad de conducto montada en el techo
VE
FXMQ140PA 1 VRV M-PA - Unidad de conducto montada en el techo
VE
Branch unit KHRP26A22 1 Refnet branch piping kit
T
KHRP26A33 1 Refnet branch piping kit
T
Option or add-on BRC1E62 3 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 5.6kg Extra refrigerant charge
Copper pipe Piping ø ¼" 16.8m Copper pipe
Piping ø ⅜" 65.2m Copper pipe
Piping ø ½" 16.8m Copper pipe
Piping ø ⅝" 18.3m Copper pipe
Piping ø ¾" 13.7m Copper pipe
Piping ø ⅞" 33.2m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 6.7kg


Extra refrigerant charge = 65.2m(ø⅜") × 0.057 + 16.8m(ø¼") × 0.022 + A + B = 5.6kg
A [ CR 112%, actual length 63.7m ] = 1.5kg
B [ 10HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
13
3.2.3. PV03 - RXQ8AYM
Model Type Model Name Qty Description
Outdoor unit RXQ8AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ40AVM 1 VRV A(AVM) - Unidad montada en pared
FXHQ63MAV 1 VRV H - Unidad suspendida del techo
E
FXMQ140PA 1 VRV M-PA - Unidad de conducto montada en el techo
VE
Branch unit KHRP26A22 1 Refnet branch piping kit
T
KHRP26A33 1 Refnet branch piping kit
T
Option or add-on BRC1E62 3 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 5.2kg Extra refrigerant charge
Copper pipe Piping ø ¼" 16.0m Copper pipe
Piping ø ⅜" 63.3m Copper pipe
Piping ø ½" 16.0m Copper pipe
Piping ø ⅝" 18.3m Copper pipe
Piping ø ¾" 45.0m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 5.9kg


Extra refrigerant charge = 63.3m(ø⅜") × 0.057 + 16.0m(ø¼") × 0.022 + A + B = 5.2kg
A [ CR 121%, actual length 61.0m ] = 1.2kg
B [ 8HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
14
3.2.4. PV04-1 - RXQ10AYM
Model Type Model Name Qty Description
Outdoor unit RXQ10AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ63AVM 1 VRV A(AVM) - Unidad montada en pared
FXHQ100MA 1 VRV H - Unidad suspendida del techo
VE
FXMQ100PAV 1 VRV M-PA - Unidad de conducto montada en el techo
E
Branch unit KHRP26A22T 1 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
Option or add-on BRC1E62 3 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 4.2kg Extra refrigerant charge
Copper pipe Piping ø ⅜" 55.4m Copper pipe
Piping ø ⅝" 11.9m Copper pipe
Piping ø ¾" 8.2m Copper pipe
Piping ø ⅞" 35.3m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 6.7kg


Extra refrigerant charge = 55.4m(ø⅜") × 0.057 + A + B = 4.2kg
A [ CR 105%, actual length 50.3m ] = 1.0kg
B [ 10HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
15
3.2.5. PV05-1 - RXQ8AYM
Model Type Model Name Qty Description
Outdoor unit RXQ8AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ50AVM 1 VRV A(AVM) - Unidad montada en pared
FXAQ63AVM 1 VRV A(AVM) - Unidad montada en pared
FXHQ100MA 1 VRV H - Unidad suspendida del techo
VE
Branch unit KHRP26A22T 1 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
Option or add-on BRC1E62 3 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 3.4kg Extra refrigerant charge
Copper pipe Piping ø ¼" 5.1m Copper pipe
Piping ø ⅜" 35.9m Copper pipe
Piping ø ½" 5.1m Copper pipe
Piping ø ⅝" 16.0m Copper pipe
Piping ø ¾" 19.9m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 5.9kg


Extra refrigerant charge = 35.9m(ø⅜") × 0.057 + 5.1m(ø¼") × 0.022 + A + B = 3.4kg
A [ CR 106%, actual length 33.1m ] = 1.2kg
B [ 8HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
16
3.2.6. PV04-2 - RXQ8AYM
Model Type Model Name Qty Description
Outdoor unit RXQ8AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ63AVM 1 VRV A(AVM) - Unidad montada en pared
FXMQ100PA 1 VRV M-PA - Unidad de conducto montada en el techo
VE
Branch unit KHRP26A33 1 Refnet branch piping kit
T
Option or add-on BRC1E62 2 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 3.4kg Extra refrigerant charge
Copper pipe Piping ø ⅜" 54.7m Copper pipe
Piping ø ⅝" 15.0m Copper pipe
Piping ø ¾" 39.7m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 5.9kg


Extra refrigerant charge = 54.7m(ø⅜") × 0.057 + A + B = 3.4kg
A [ CR 81%, actual length 53.2m ] = 0.3kg
B [ 8HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
17
3.2.7. PV05-2 - RXQ8AYM
Model Type Model Name Qty Description
Outdoor unit RXQ8AYM 1 Cooling only VRV A(18,20HP single module)
Indoor unit FXAQ63AVM 1 VRV A(AVM) - Unidad montada en pared
FXHQ100MA 1 VRV H - Unidad suspendida del techo
VE
Branch unit KHRP26A33T 1 Refnet branch piping kit
Option or add-on BRC1E62 2 Wired Remote Controller (Navigation Remote
Controller)
Refrigerant R410A 2.4kg Extra refrigerant charge
Copper pipe Piping ø ⅜" 36.2m Copper pipe
Piping ø ⅝" 16.0m Copper pipe
Piping ø ¾" 20.2m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 5.9kg


Extra refrigerant charge = 36.2m(ø⅜") × 0.057 + A + B = 2.4kg
A [ CR 81%, actual length 33.4m ] = 0.3kg
B [ 8HP ] = 0.0kg

The capacity for 14.0-15.9CWB are at VRT powerful mode.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
18
4. Piping Diagrams
Pipes marked with a short red stripe in the diagrams must be connected to the device with a reducing joint.

4.1. Piping PV01


PV01
RXQ10AYM

35.2m 13.1m 1.8m


⅜"×⅞" ⅜"×¾" ⅜"×⅝"
KHRP26A33T KHRP26A22T

UI1
FXMQ140PAVE
18.1m
¼"×½"

UI3
FXAQ50AVM
17.9m
⅜"×⅝"

UI2
FXHQ100MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
19
4.2. Piping PV02
PV02
RXQ10AYM

33.2m 13.7m 1.3m


⅜"×⅞" ⅜"×¾" ⅜"×⅝"
KHRP26A33T KHRP26A22T

UI1
FXMQ140PAVE
16.8m
¼"×½"

UI3
FXAQ40AVM
17.0m
⅜"×⅝"

UI2
FXMQ100PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
20
4.3. Piping PV03
PV03
RXQ8AYM

34.2m 10.8m 1.6m


⅜"×¾" ⅜"×¾" ⅜"×⅝"
KHRP26A33T KHRP26A22T

UI1
FXMQ140PAVE
16.0m
¼"×½"

UI3
FXAQ40AVM
16.7m
⅜"×⅝"

UI2
FXHQ63MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
21
4.4. Piping PV04-1
PV04-1
RXQ10AYM

35.3m 1.5m
⅜"×⅞" ⅜"×⅝"
KHRP26A33T

UI1
FXMQ100PAVE
8.2m 3.6m
⅜"×¾" ⅜"×⅝"
KHRP26A22T

UI2
FXHQ100MAVE
6.8m
⅜"×⅝"

UI3
FXAQ63AVM

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
22
4.5. Piping PV05-1
PV05-1
RXQ8AYM

19.9m 2.8m
⅜"×¾" ⅜"×⅝"
KHRP26A33T

UI1
FXHQ100MAVE
3.2m 5.1m
⅜"×⅝" ¼"×½"
KHRP26A22T

UI2
FXAQ50AVM
10.0m
⅜"×⅝"

UI3
FXAQ63AVM

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
23
4.6. Piping PV04-2
PV04-2
RXQ8AYM

39.7m 1.5m
⅜"×¾" ⅜"×⅝"
KHRP26A33T

UI1
FXMQ100PAVE
13.5m
⅜"×⅝"

UI3
FXAQ63AVM

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
24
4.7. Piping PV05-2
PV05-2
RXQ8AYM

20.2m 2.8m
⅜"×¾" ⅜"×⅝"
KHRP26A33T

UI1
FXHQ100MAVE
13.2m
⅜"×⅝"

UI3
FXAQ63AVM

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
25
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring PV01


P1,P2
PV01 UI1 BRC1E62
RXQ10AYM FXMQ140PAVE
IN F1,F2 F1,F2
L1,L2,L3,N 21.2A 3ph L, N 3.4A 1ph
P1,P2
UI3 BRC1E62
FXAQ50AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UI2 BRC1E62
FXHQ100MAVE
F1,F2
L, N 1.3A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
26
5.2. Wiring PV02
P1,P2
PV02 UI1 BRC1E62
RXQ10AYM FXMQ140PAVE
IN F1,F2 F1,F2
L1,L2,L3,N 21.2A 3ph L, N 3.4A 1ph
P1,P2
UI3 BRC1E62
FXAQ40AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UI2 BRC1E62
FXMQ100PAVE
F1,F2
L, N 2.9A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
27
5.3. Wiring PV03
P1,P2
PV03 UI1 BRC1E62
RXQ8AYM FXMQ140PAVE
IN F1,F2 F1,F2
L1,L2,L3,N 16.1A 3ph L, N 3.4A 1ph
P1,P2
UI3 BRC1E62
FXAQ40AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UI2 BRC1E62
FXHQ63MAVE
F1,F2
L, N 0.9A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
28
5.4. Wiring PV04-1
P1,P2
PV04-1 UI1 BRC1E62
RXQ10AYM FXMQ100PAVE
IN F1,F2 F1,F2
L1,L2,L3,N 21.2A 3ph L, N 2.9A 1ph
P1,P2
UI2 BRC1E62
FXHQ100MAVE
F1,F2
L, N 1.3A 1ph
P1,P2
UI3 BRC1E62
FXAQ63AVM
F1,F2
L, N 0.7A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
29
5.5. Wiring PV05-1
P1,P2
PV05-1 UI1 BRC1E62
RXQ8AYM FXHQ100MAVE
IN F1,F2 F1,F2
L1,L2,L3,N 16.1A 3ph L, N 1.3A 1ph
P1,P2
UI2 BRC1E62
FXAQ50AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UI3 BRC1E62
FXAQ63AVM
F1,F2
L, N 0.7A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
30
5.6. Wiring PV04-2
P1,P2
PV04-2 UI1 BRC1E62
RXQ8AYM FXMQ100PAVE
IN F1,F2 F1,F2
L1,L2,L3,N 16.1A 3ph L, N 2.9A 1ph
P1,P2
UI3 BRC1E62
FXAQ63AVM
F1,F2
L, N 0.7A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
31
5.7. Wiring PV05-2
P1,P2
PV05-2 UI1 BRC1E62
RXQ8AYM FXHQ100MAVE
IN F1,F2 F1,F2
L1,L2,L3,N 16.1A 3ph L, N 1.3A 1ph
P1,P2
UI3 BRC1E62
FXAQ63AVM
F1,F2
L, N 0.7A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
32
6. Device Options

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
33

You might also like