RE 30111
Edition: 2013-11
Type VT-VSPA1-1, VT-VSPA1K-1 Replaces: 10.10
▶ Component series 1X
▶ Suitable for the control of all direct and pilot operated
proportional pressure valves without electrical position
feedback and only one solenoid as actuating element
available at the time of the data sheet publication
H5897_d
Features Contents
Ordering code
01 02 03 04 05
VT-VSPA1 – 1 – 1X / *
01 Amplifier for controlled proportional pressure valves, analog, with one solenoid VT-VSPA1
04 Component series 10 to 19 (10 to 19: Unchanged technical data and pin assignment) 1X
Suitable card holders for VT-VSPA1-1: When replacing amplifiers VT 2000 (up to component
▶ Type VT 3002-1-2X/32D, see data sheet 29928 series 4X), VT 2010, VT 2013 or VT 2023, the blind
Single card holder without power supply unit plate 4TE/3HE must be ordered separately for the
rack mounting.
Material no. R900021004
Function
The command value voltage is specified at the command Differential input (input 2)
value input 1 either directly or via an external command
value potentiometer by means of the regulated voltage +9 V 0 … +10 V / 4 … 20 mA 28(ac)
of the power supply unit [14]. 0 … 20 mA u (i)
To this input, the following applies: +9 V ≙ +100 % 1).
0 V reference potential
30(ac) u
External command value presetting
The amendment of the connection
12(ac) designations in brackets only
Input 1
applies to type VT-VSPA1-1.
10(ac) +9 V
5K
14(ac) M0 The command value input 2 is a differential input [1]
(0 to +10 V). By means of DIL switches 2), it can be config-
18(ac)
ured as current input (+4 to +20 mA or 0 to +20 mA). If the
command value is specified by external electronics with
a different reference potential (e.g. by a PLC), this input
Notice:
has to be used. When disconnecting or connecting the com-
If an external command value potentiometer is used, the
mand value voltage, it has to be ensured that both signal
internal potentiometer "Gw" [3] must be set to maximum or
lines are in each case separated from or connected with
to the desired maximum pressure.
the input.
Before they are forwarded, both command values are
Internal command value presetting
summed up [2] and then reach a potentiometer [3] acces-
12(ac) Input 1 sible at the front plate of the card which acts as attenuator
and thus limits the maximum command value.
10(ac) +9 V
Function (continued)
The down-stream ramp generator [4] generates a ramp- The ramp generator [4] output signal is forwarded to the
shaped output signal from a given stepped input signal. The summing amplifier [5] as current command value. Here,
time constant of this signal can be separately adjusted for a voltage of +6 V corresponds to a command value
the upwards and downwards direction by means of two of 100 %.
potentiometers. The specified ramp time refers to a com-
mand value step of 100 % and may be approx. 1 s or 5 s, In the summing amplifier [5], the output signals of the
depending on the setting by means of a DIL switch 2). If characteristic curve generators [6 or 7] are added to the
a command value step of less than 100 % is switched to the command value (can be selected by means of DIL
ramp generator input or if the attenuator [3] is effective, switches 2) depending on the valve to be controlled). The
the ramp time will be correspondingly shorter. current command value can be filtered by means of a con-
To type VT-VSPA1-1, the following applies: By means of the nectible low pass. The current output stage [9] is con-
external "ramp up/down off" contacts, the upwards and trolled using the current controller [8]. In the current con-
downwards ramp times can be separately set to their mini- troller, the current command value is moreover modulated
mum value (approx. 30 ms). with the clock generator signal [10] (frequency can be
To type VT-VSPA1K-1, the following applies: By means of programmed using the DIL switch 2)). In the valve solenoid,
the external "ramp off" contact, the upwards and down- the clocked actual current value acts like a constant current
wards ramp times can be set to their minimum value with superimposed dither signal. Type VT-VSPA1-1 has
(approx. 30 ms) together. measuring sockets for the internal command value and the
actual value.
Ramp "up/down" off The following is true for the command value: +6 V ≙ 100 %
The following is true for the actual value: 1 mV ≙ 1 mA
VT-VSPA1-1 The "ready for operation" signal is output and the "H2" LED
on the front plate (with VSPA1-1) or the "H2" LED
2a Ramp "up" off (with VSPA1K-1) is illuminated if:
2c ▶ there is no short-circuit of the solenoid conductors and
Ramp "down" off
no overload of the output stage,
4ac
▶ a command value is available (cable break detection),
▶ there is no cable break of the solenoid conductor.
In case of a fault, the following applies:
VT-VSPA1K-1 Output LED
Short-circuit Low Off
2 Cable break Clocking Flashing
Ramp off
1) The reference potential for command value 1 is M0 (mea-
4 surement zero).
2) For the DIL switch settings see page 8 to 10
Command value
Ramp 2a "w"
"up" off
2c
Ramp 32ac Command
"down" off 4ac value 0...6 V
Zw (R130) f–3dB S23 S24 14ac
6
12ac 4 0 off off
Command value 1 Characteristic
S15
Σ 2.5 Hz off on
Gw curve 1
2 4 Hz on off
Σ
3 7 S23 / S24
5 S16
Characteristic 15
S11...S13 S14 curve 2 Icommand
4 … 20 mA on on on
Block diagram/pin assignment: VT-VSPA1-1
200 Hz off on on
6ac 10
300 Hz off off on
8ac
22ac
8
12 u
10ac i 20ac
+ 9 V (25 mA)
& 11
14ac S17 off on 9
M0 (25 mA) S17
Imax 1.6 A 0.8 A
16ac 13
– 9 V (25 mA) Actual current value
"I"
18ac Actual cur-
0V DC H2 26a rent value
1 mV ≙ 1 mA
24ac
+ 24 V DC 26c Ready for opera-
2,5 A T + 24 V
tion 24 V (50 mA)
14 17
Ramp off 2
Command
32
4 value output
Zw (R130) f–3dB S23 S24 14 0...6 V
6
0 off off
Command 12 4 S15
value 1 Σ Characteristic 2.5 Hz off on
Gw curve 1
4 Hz on off
2 Σ
3 7 S23 / S24
5 Characteristic
S16 15
S14 curve 2 Icommand
S11...S13
Command value 2 t t S14 on off Σ ⬃
+10 V 28 Command S11 S12 S13 tmax 5s 1s
4...20 mA / 0...20 mA U/I value 2
16
30 U fclock S25 S26 S27
GND ⊥ 0…10 V off off off S25...S27
1 0…20 mA on on off 100 Hz on on on
4 … 20 mA on on on 200 Hz off on on
6 10 300 Hz off off on
Block diagram/pin assignment: VT-VSPA1K-1
8
22
8
12 u
10 i 20
+ 9 V (25 mA)
& 11
14 S17 off on 9
M0 (25 mA) S17
13 Imax 1.6 A 0.8 A
16
– 9 V (25 mA)
18
0V DC H2 26 Actual cur-
rent value
1 mV ≙ 1 mA
24
+ 24 V DC
2,5 A T
14
Technical data (For applications outside these parameters, please consult us!)
Characteristic curves
A
1600 800
Output current in mA →
1200 600
I2
800 400
600 300
400 200
I1
200 100
0 0
0 50 100
Command value in % →
1600 800
2
Output current in mA →
1
1200 600
I2
800 400
400 200
IV 200 100
100 50
0 0
0 50 100
Command value in % →
Display/adjustment elements
1
2
3
4
5
6
7
Ramp time "up" t
X1
F2
R130 2,5 A MT
Ramp time "down" t
BR11...BR17
w - current command value w ON
1
2
3
4
5
6
7
I - actual current value I
VT-VSPA1-1, from component Potentiometer for pilot DIL switch DIL switch
current adjustment group S2X group S1X
series 11
7
Zw 6
5
"Ready for operation" LED display H2 4
3
2
1
X1
F2
2,5 A T
Ramp time "down" t
w - current command value w
I - actual current value I
F2
2,5 A T
Ramp time "down" t
H2
32
Command value 2
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRE(M)10-5X, ON ON ON
DRE(M)20-5X X +10 V
DBE(M)10-5X,
DBE(M)20-5X, 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
ON ON ON
3DRE(M)10P-6X, X 0 … 20 mA
3DRE(M)16P-6X,
ZDRE10, (Z)DBE6
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRE6, ON ON ON
ZDRE6 X 4 … 20 mA
1) To component series 5X
Notice:
It has to be ensured before commissioning of the amplifiers
that the DIL switches on the printed circuit board are set
according to the relevant application.
Switch settings with regard to current valve types or previous amplifier cards
Valve types/amplifier cards
DBE(M)T, DBE(M)30 DBE(M)10-5X
DRE(M)30, DRE(M)10 3) DBE(M)20-5X
Switch DRE(M)16 3) DRE(M)10-5X ZDRE10
DRE, ZDRE6
DBEP6A, DBEP6B DRE(M)20-5X (Z)DBE6
3DREP6A, 3DREP6B 3DRE(M)10P-6X
Pumps 3DRE(M)16P-6X
VT 2000 VT 2010 VT 2013 VT 2023
Characteristic curves
Basic characteristic curve Characteristic curve 1 Characteristic curve 1 Characteristic curve 2
S15 (BR15) OFF ON ON OFF
S16 (BR16) OFF OFF OFF ON
Command value filter
f-3dB = 4 Hz f-3dB = 4 Hz f-3dB = 2.5 Hz
S23 (BR23) OFF ON ON OFF
S24 (BR24) OFF OFF OFF ON
Max. output current 1)
Pilot current setting range by means of the ( ) applies to VT-VSPA1-1, component series 10
"Zw" (R130) potentiometer:
Upon operation of switch BR22, the pilot current is increa-
Imax = 800 mA → Iv = 0 to 300 mA
sed by 50 mA or 100 mA.
Imax = 1600 mA → Iv = 0 to 600 mA
Adjustment options independent of the valve type (command value 2 and ramp time)
Configuration of the differential input
Command value 2: +10 V Command value 2: 0 to 20 mA Command value 2: 4 to 20 mA DRE, ZDRE6
S11 (BR11) OFF ON ON
S12 (BR12) OFF ON ON
S13 (BR13) OFF OFF ON
Max. ramp time
S14 (BR14) OFF ≙ 1 s ON ≙ 5 s
VT-VSPA1-1
H2
Gw
3HE (128,4)
100
89
t
t
w
I
Ø8
M0
VSPA1
4TE 2
(20) 7 165
182
VT-VSPA1K-1 164
X1
104
100
80
4 x Ø 4,5
10
10 135
160
Troubleshooting
Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be repro-
Zum Eisengießer 1 duced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 18-0 concerning a certain condition or suitability for a certain application can be
documentation@boschrexroth.de derived from our information. The information given does not release the user
www.boschrexroth.de from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.