HINDUSTAN PETROLEUM CORPORATION LIMITED

(A Government of India Enterprise)

QUALITY CONTROL LABORATORY


HASSAN TERMINAL
PLOT NO.1-A, KIADB INDS AREA, MYSORE ROAD
HASSAN 573201

TEST REPORT
Product : HSD - BS VI

Customer / Supplier / : Hassan Terminal Test Report No. : BFT/5132

Branch Plant Date of Sample Drawn : 19/06/20


Source of Sample : TK204 Date of Sample Receipt : 19/06/20

Tank No : TK204 . . Date of Sample Testing : 19/06/20

Qty of Sample/ : 3x1l

Density/Type of Sample Date of Report : 19/06/20


Catg / Evnt / Actvty : After Rct tru Multi Prod P/L Date of Printing : 19/06/20

Receipt/Despatch Mode : for BFT JDE Sample Number : 962522

Sample Drawn by : HCK/MOHAN Batch No :

Specifications
Test Line Characteristics Units Test Method Min Max Result Value
Number
4 DENSITY AT 15 °C - TOP Kg/M3 IS 1448 P : 16 810.0 845.0 823.1
5 DENSITY AT 15 °C - MIDDLE Kg/M3 IS 1448 P : 16 810.0 845.0 823.1
6 DENSITY AT 15 °C - BOTTOM Kg/M3 IS 1448 P : 16 810.0 845.0 823.1
9 95% V/V RECOVERY °C °C IS 1448 P :18/ISO 3405 - 360.0 350.5
10 KINEMATIC VISCOSITY @ 40°C cSt IS 1448 P :25 2.000 4.500 2.497
11 TOTAL SULPHUR mg/kg ISO-13032 - 10.0 3.7
12 FLASH POINT ABEL °C IS 1448 P :20 35.0 - 64.5
14 CU STRIP CORR FOR 3 HR AT 50°C . IS 1448 P :15/ISO 2160 - 1 1
15 POUR POINT SUMMER °C IS 1448 P:10 - 15 -6
17 CETANE INDEX . ASTM D 4737/ISO 4264 46.0 - 54.3
19 TOTAL SULPHUR - TOP mg/kg ISO 13032 - 10.0 4.8
20 KINEMATIC VISCOSITY@ 40°C -TOP cSt IS 1448 P :25 2.000 4.500 2.503

Remarks:
Lab Sr No. 36

Appearance: - Clear, bright and free from sediments, suspended matter and undissolved water at normal ambient fuel temperature
Sample Meets IS 1460 - 2017 Specifications for Automotive Diesel Fuel for BS VI in the above tests.

Notes : 1) The sample is drawn by client and results relate to sample tested
2) The test report shall not be reproduced except in full without prior written approval of the Lab Incharge
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory
4) Test results reported are valid at the time of testing
5) This is a system generated test report and hence does not require signature