SEPB201301

Service Technology Development Group


EMMS: Equipment Management Monitoring System Customer Support Division

- Moves Left

- Moves Right

- Selects Mode

ν - Cancels Mode

- Maintenance Mode Functions -

Ignition key must switched to the "ON" position.


When using the “Select Mode” to access menu, the
switch must be held in the ❑ position at least 4 to 6
seconds in order to access menu functions in the
Operator Mode.

Normal
Normal Monitor
Monitor Display
Display Key
Key "ON"
"ON"

Scroll through the menu


ν
ν or

select YES or NO

The maintenance interval is re-set and the


YES enter monitor display returns to the maintenance item
chosen.

NO enter No action is taken.

NO enter ν The maintenance item is not re-set and the monitor


display returns to the maintenance item chosen.

- PM Clinic Functions -

An Action Code will automatically be


displayed when a serious fault occurs
in the system. There are 4 Action
Codes.

E01 3Only action code is displayed


Contents of Fault:
•Backup alarm does not sound
Scroll through the menu
•Fan speed is locked in maximum
speed After selecting the system to be monitored from
ν or the menu shown above, you can take a snap-shot
Remedy: of a time frame within that system.
By using the select mode function you can capture and hold a time frame within a systems.
•Automatic functions stop An “H” will appear on the left of the screen and all monitored movement will hold until canceled.

•Stop! Call your Komatsu dealer Select and hold “H” Cancel hold ν Exit function
- Error Code Functions -

E02 3Action code is displayed


3Caution lamp flashes
3Caution buzzer sounds
Contents of Fault:
•Gears are not shifting up or down
•Engine boost pressure incorrect
•Abnormal exhaust color
Remedy:
•Stop engine and restart machine
•Stop ! Call your Komatsu dealer ν

If a problem is detected in the operating systems, the monitor read-out will display one of two
indications. These would be a display with the words “!!ERROR CODE!! This is usually followed
by an audible warning as well as a separate indication elsewhere. The other display would be the
actual “FAULT CODE” display listing for the system with a problem. This is usually indicated by
a six digit display specifically for the system with the problem. The monitor is capable of sorting
E03 3Action code is displayed 20 items, each will be displayed automatically every two seconds in the order of occurrence.

3Caution lamp flashes


3Caution buzzer sounds - User Adjust Functions -

Contents of Fault:
•Engine coolant sensor is defective
•Gear speeds are limited
•Rough gear shifting
•Slow steering response
•Lack of brake control
Remedy:
•Move to a safe location and shut
machine down immediately
•Stop ! Call your Komatsu dealer

Scroll through the menu

ν or Increase intensity

E04 3Action code is displayed Decrease intensity

3Caution lamp flashes After selecting desired brightness or contrast


The mode is now set, and can be changed
3Caution buzzer sounds
Contents of Fault: or out ν
•Engine control system inoperable
•Machine will not move
•Machine stops Turn engine off to reset fan rotational
direction
Remedy:
•Move to a safe location and shut
machine down immediately
•Stop ! Call your Komatsu dealer
ν Fan rotation is normal

No action No action
EMMS: Equipment Management Monitoring System

- Moves Left

- Moves Right

- Selects Mode

ν - Cancels Mode

Ignition key must switched to the "ON" position


and the machine must be in the "PARK" mode in
order to allow access to the functions on the monitor
display when in the Service Mode.

Normal
Normal Monitor
Monitor Display
Display Key
Key "ON"
"ON"

To access Service Mode, hold toggle switch in


“UP”position together with the “Select Mode”
switch for 6 to 8 seconds.

Scroll through the menu

ν or

To change time interval You have two options in this mode:


“UP” (increases numeric value) 1. Re-set the maintenance time interval.
2. Cancel systems operation
“DOWN” (decreases numeric value)

Cursor location If you do not use the maintenance function

Move Left Move Right Set values at zero, maintenance alert will not be
used and no warning will be set in system
No setting ν or

Maintenance time interval is chanced Value out of range, try again


ν

To display all codes, use Left, Right feature. Up


to 20 codes can be recorded and displayed. Codes
are stored in order of oldest to the newest. A
flashing code means the fault is currently Previous code (Left) Next code (Right)
happening.
Erase all codes in system
“UP” (erases codes)

If a code cannot be erased, this is an indication the “DOWN” (erases codes)


electrical problem has not been repaired and is
continuing to re-occur.

Exit system ν No Action

To display all codes, use Left, Right feature.


Up to 20 codes can be recorded and displayed.
Codes are stored in order of oldest to the newest.
A flashing code means the fault is currently Previous code (Left) Next code (Right)
happening.
No codes in system

Mechanical system error codes cannot be deleted

Exit system ν No Action


Record number (Up to 20 Codes)
Time measure after first occurrence
Time measured after last occurrence
Read-out Explanation
Number of past occurrences
ν

By using the “Shift-up” and “Shift-down” buttons you can scroll


through the numbers to enter the code for the item you select. By
using the < > feature you can position the cursor on a digit.

Setting Numbers
“UP”
(increase numbers)

“DOWN”
(decrease numbers)

Previous number (Left) Next number (Right)

After entering the item number code

ν
Items marked with a star can be displayed using the < or > feature.

To change or re-set a function use:


“UP” (sets value)
To set a function

ν “DOWN” (sets value)

Function will be set if system allows access

In this system 10 functions can be set using the


buttons shown on the right. If a system cannot be Turns function ON or OFF
re-set the menu shown above will indicate as shown
or simply allow a read only of the item. ON OFF

Moves cursor
ν

Read only, cannot be reset

Scroll through menu

Read only, cannot be reset Read only, cannot be reset

Setting Numbers
“UP”
(increase numbers) See Monitoring Mode Table for a list of system codes

“DOWN” After entering the item number code


(decrease numbers)
Exit System ν

Previous number (Left) Next number (Right)

By using the select mode function you can capture and hold a
In this mode you can read a systems function time frame within a systems. An “H” will appear on the left of the
by simply entering an access code. Once in the system screen and all monitored movement will hold until canceled.
you can scroll through other systems.
Select and hold “H” Cancel hold Exit function ν
ν

Setting Numbers
“UP”
(increase numbers)
See Monitoring Mode Table for a list of system codes

“DOWN” After entering the item numbers code


(decrease numbers)
Exit System ν

Previous number (Left) Next number (Right)

In this mode you can view two systems functions


at the same time by simply entering two access code. ν
No action No action Exit system