File No: 5039464 Inspection Report No.:-LUD/RU/58/2021

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

SGS India Pvt. Ltd.

Inspection report
File No : 5039464 Inspection Report No. :- LUD/RU/58/2021
Place of inspection: Banmajra, (ROPAR). Date of inspection :11/03/2022
Time In : 10:10 Am Time Out : 5:40 Pm
Name of the Project ( if any ) CB-2077(SP 502), M/s JIGAWA RICE Ltd , NIGERIA
(15TPH/10.54 Kg/cm2(g) HYPAC)
Name of Client M/s Jigawa Rice Ltd, NIGERIA
Name Seller / Manufacturer / Vendor M/s Cheema Boilers Limited, Vill Banmajara, Kurali Dist.
Ropar pin 140103,
Client’s P/O No. & Date CBL 825 REV.04/SP:2020-21 DATE 17.05.2021
Date of last inspection -----
Inspection call reference E MAIL DATED 05.03.2022
Status of previous hold points / Deviation -----
P.O. Status: Completed / Balance / Hold BALANCE

Item # Quantity
Quantity Quantity
as per as per Quantity Quantity Quantity
Description & Size Previousl Now
Contra Contract Offered Rejected Balance
y passed Passed
ct/ / Order (Nos.) (Nos.) (Nos.)
(Nos.) (Nos.)
Order (Nos.)
15 TPH Rice Husk Fire Boiler: -

Down Comer ,Risers ,DWLG ,APH


Hopper,Cyclone with
cone,Electrical Panel,Water 1465 NiL 1464 1464 Nil 01 Pcs
Softener,Asbestos mill board 5 Pcs Pcs Pcs
mm thk (1mtr x 1mtr),Insulite 7
(40kg),Ceramic Blanket 96 kg/m3
(25 thk),Fire Clay (50kg),Accoset
50 (50 kg),SS Wire mesh ,S.Arch
Skew Block ,Coir rope ,Electrical
components,Boiler Shell
Tubes,Inbed Tubes,Feed Pump
Without Motor,FD Fan Tyre
Coupling,Air & Flue Gas Ducting
Bend & Reducer / Ex-
panders,Screw Feeder Without
Motor.

Refer attached offer lists/


Inspection report
* Inbed Tube Assy. Is not offered during inspection.

VF-IN-IND-IN-012 / Ver 2.3 /01-03-2022/ Page 1 of 3


SGS India Pvt. Ltd.

Inspection Report No : LUD/RU/58/2022 5039464


Annexure No of
Reference Documents Scope of inspection and Status
Detailed report

PO No. & Date: CBL 825 Scope: - As per Email dt 05.03.2022: - visual Annexure-A
REV.04/SP:2020-21 DATE inspection, dimensions check, quantity
17.05.2021 verification, review of inspection reports as
QAP / ITP No :N.A. applicable.
Revision :.
Status: -

Quantity: - All the pcs. were physically counted


& verified for Quantity.
Visual Check:- All the above sampled pieces
were checked visually (General) for Finish /Paint
Approved Drawing No. :CB2077-03-
Finish, Paint peel off, Dents, Flow of paint, Burr
29-3-001/A,CB2077-03-30-3-
& welding defects like pin holes, under cuts,
001/NIL,CB2077-03-04-0-
porosity, spatters as applicable & found
002.NIL,CBL-PB-AHD14-3-
satisfactory.
001/A,CBL-PB-CT14-2-001/D,SP502-
Inbed Tube Assy. Is not offered during inspection
2021-03-25-3-001/NIL,SP502-2021-
18-00-3-001/NIL,SP502-2021-18-00-
3-001/NIL,SP502-2021-10-04-4-001
Dimension Check: - All the sampled pieces
TO 004/NIL & CB-FD-008-200-450-
were Random checked as per Drawing/ Internal
01/A
Dimension report & found satisfactory. Refer
report attached.
Revision :
Review of Inspection report & Calibration T.C
Reference standard / code /
specification & Edition / Version /
Year : Manufacturer Specifications,
Drawings

Sampling Standard & Edition /


Version / Year: As Per ISO 2859 S-4
Visual Check & Dimension check
Sampled Pieces: -32 Nos.

Current Hold points / Deviations :Refer remarks

Remarks:-
Inbed Tube Assy. Is not offered during inspection
Inspection carried out as per E-mail dated 05.03.2022

Enclosure Quantity Details of part (offer list). Joint inspection Report MTC Calibration T/C

VF-IN-IND-IN-012 / Ver 2.3 /01-03-2022/ Page 2 of 3


SGS India Pvt. Ltd.

Detailed Inspection Report


File No: 5039464 Annexure No : ANNEXURE-A
Report No and Date- LUD/RU/58/2022 DATED 11/03/2022 Page : 01 of 01
Material and Quantity inspected: - Total Quantity 1464 pcs. CB 2077 for details refer attached offer lists.

Sr. No. Details of activity performed, findings and product marking Conclusion

- Scope: - As per Email dt 05.03.2022: - l for visual inspection, dimensions Satisfactory for
check, quantity verification, review of inspection reports as applicable. carried out
activities except
Status: - Inbed tube
assembly.
Quantity: - All the pcs. were physically counted & verified for Quantity.
Refer remarks
Visual Check:- All the above sampled pieces were checked visually column.
(General) for Finish /Paint Finish, Paint peel off, Dents, Flow of paint, Burr &
welding defects like pin holes, under cuts, porosity, spatters as applicable &
found satisfactory.
Inbed Tube Assy. Is not offered during inspection

Dimension Check: - All the sampled pieces were Random checked as per
Drawing/ Internal Dimension report & found satisfactory. Refer report attached.

Review of Inspection report & Calibration T.C

Number of Photographs taken : 15 Snaps .


Confirm Instruments used are in working condition & suitable for intended purpose : YES / NO
Verified the Qualification, Training & Experience of the person performing the test before witness: YES / NO
Instrument Name & Calibration Calibration Calibrated By Calibration Traceable to National
Identification No. date due date / International standard
Steel Tape (5 & 15 Mtr) 10.01.2022 09.01.2023 ICL Calibration & Traceable to National standard
Vernier Caliper 05.07.2021 04.07.2022 testingServices Traceable to National standard
Ultrasonic gauge Vernier Caliper 20.12.2021 19.12.2022 Johari Engineering
Verified the Calibration Certificates of above mentioned Instruments also for Accuracy, Uncertainty & % Error before
allowing / using it for test / inspection and found suitable : YES / NO
REMARK:- In case test certificates of bought items/raw materials are not from accredited laboratory, SGS
responsibility is limited to verify the test results against the requirement and not to assess the accuracy / suitability
of results specified in the test report.

Inspection Identification Location of identification Name and signature of SGS Name and signature of Manufacturer
(Actual Impression) representative / Vendor representative

Single Rubber
Stamped on sampled (Rahul uppal) (Mr. Vishal Garg)
pcs. 9466140040

Disclaimer:
This document does not have any Legal or Commercial value and hence cannot used for any commercial and legal purposes.
This is just a site report applicable at the time, date and place of inspection
Final Negotiable Document as agreed shall be obtained from SGS Office
Debriefing & Vetting Status :
Name & sign of Vetting authority :

VF-IN-IND-IN-012 / Ver 2.3 /01-03-2022/ Page 3 of 3