Professional Documents
Culture Documents
Foundations and Column Pedestals: General Notes
Foundations and Column Pedestals: General Notes
Foundations and Column Pedestals: General Notes
A) STEEL STRUCTURE:-
PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2 PS2
PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1 PS1
TABLE OF PEDESTALS
----
TABLE OF FOOTINGS
F1
F2
TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1
F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1
F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2
TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
THIS DRAWING IS THE PROPERTY OF CIVIL AND MUST NOT BE LENT, COPIED OR
REPRODUCED TO ANYBODY WITHOUT HIS WRITTEN PERMISSION.
F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1
TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1
FOUNDATIONS AND
COLUMN PEDESTALS
ST-01
GENERAL NOTES:
A) STEEL STRUCTURE:-
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
B3
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
thinner plate to be welded.
13. Bolts used are H.S.B. of Grade 10.9 and 20mm Diameter unless
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
otherwise specified.
14. Bolts Used for Bracing Systems are High Strength Bolts of Type
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 8.8 and Diameter 16 mm
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
MB1
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
B3
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2
B2
B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1
TABLE OF PEDESTALS
----
TABLE OF FOOTINGS
F1
F2
3000
RC100 MM Over Metal Deck
11100
500
8800
MB1-1 MB1-1 MB1-1
MB1-2 MB1-2 MB1-2 MB1-2
No. Revision / Issue Date
THIS DRAWING IS THE PROPERTY OF CIVIL AND MUST NOT BE LENT, COPIED OR
REPRODUCED TO ANYBODY WITHOUT HIS WRITTEN PERMISSION.
4576
C1 C2 C2 C1
ST-02
GENERAL NOTES:
A) STEEL STRUCTURE:-
1. All dimensions of steel details are in mm unless otherwise
specified.
2. All dimensions and levels must be checked before
manufacturing.
3. The design is done according to the Egyptian code of practice
STEEL CONSTRUCTION AND BRIDGES CODE No. ECP
205-2001.
B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 4. The steel used for built-up sections is St.52 with yield stress of
3600 kg/cm² and ultimate stress of 5200 kg/cm².
5. All welds are workshop welds.
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 6. Min size of fillet weld is 5.0 mm, unless otherwise specified and
must be checked according to specifications.
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 7. All contact surfaces at bolted connection should be adequately
treated by sand blasting or girt blasting.
MB1
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
B3
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
otherwise specified.
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
13. Bolts Used for Bracing Systems are High Strength Bolts of Type
8.8 and Diameter 16 mm
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
MB1
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB2
MB1
B3
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
B2
B2
B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1
TABLE OF PEDESTALS
----
TABLE OF FOOTINGS
3000
WIDTH LENGTH THICK. WIDTH LENGTH THICK.
F1
F2
RC100 MM Over Metal Deck
11100
500
8800
TABLE OF FLOOR BEAMS
MB1-1 MB1-1 MB1-1
MB1-2 MB1-2 MB1-2 MB1-2
FLANGE WEB NOTES No. Revision / Issue Date
MODEL THIS DRAWING IS THE PROPERTY OF CIVIL AND MUST NOT BE LENT, COPIED OR
TOP BOT. START END REPRODUCED TO ANYBODY WITHOUT HIS WRITTEN PERMISSION.
4576
B2 190x10 190x10 400 x 6 400 x 6
TABLE OF COLUMNS
ST-03