Heat Treatment Procedure For Coil Header:::::: Purchaser End-User Project Name Location Item No. &service Name
Heat Treatment Procedure For Coil Header:::::: Purchaser End-User Project Name Location Item No. &service Name
4 - FOR INFORMATION BY :
The responsibility of the performance and safety of equipment remain entirely with Supplier
This specification is applied to the heat treatment of the following header pipes.
2. Applicable Code
3. Applicable Drawing
4. Heat Treatment
Prior to heat treatment, the surface of the material to be heat treated shall be check that there are no
contamination, grease, paint and etc..
The temperature of the furnace shall not exceed 300oC at the time when the material to be heat treated in place
in it.
Above 300oC, the rate of heating shall be not more than 200oC/hr.
The heat treated material shall be hold at or above the temperature specified in UCS-56 (ASME Sec.VIII Div.1).
During the heating and holding periods, the furnace atmosphere shall be so controlled as to avoid excessive
oxidation of the surface of the heat treated material.
Above 300oC, the rate of cooling shall be not more than 250oC/hr.
From 300oC, the heat treated material may be cooled in still air.
Temperature : 625±25oC
Holding Time : 1 hour
625±25oC
Max. Max.
200oC/hr. 1 hour 250oC/hr.
5. Record
Heating rate, holding temperature/time, and cooling rate shall be recorded and documented on the heat
treatment chart.