STANDARDS SPECIALIST
PREPARED BY: S. GARCIA STANDARDS ENGINEERING - 8126
MANAGER
APPROVED FOR CONTENT: D. PALMER NON-PRESSURE PART ENGINEERING - 9814
PROGRAM MANAGER
APPROVED FOR PUBLICATION: T. MISKELL STANDARDS ENGINEERING - 826
PRODUCT LINES: CHECK THE PRODUCT LINES THAT THE STANDARD IS APPLICABLE TO
Versions
The criteria in this document are minimum Only U.S. accredited Codes and Standards
standards acceptable to ALSTOM Power for shall be used throughout the manufacturing
ceramic fiber blanket insulation for use on fossil- processes and all material furnished shall comply
fired steam generators. with their requirements.
All quotations must comply with this Reference to such Codes and Standards
specification. shall mean the latest edition and addenda,
effective at the date of order unless specifically
Compliance with these specifications shall stated otherwise.
not release the Vendor from following industry
practices in regard to quality and workmanship. 4.0 Material (Physical) Requirements
Ceramic fiber blanket is a flexible asbestos The ceramic fiber blanket insulation
free insulation manufactured as a needle felted shall be furnished in 2’-0” (610 mm) widths x
product that does not contain organic or 25’-0” (7620 mm) long in thicknesses of 1/4"
inorganic binders. (6 mm), 1/2” (13 mm), 1” (25 mm), 1-1/2”
(38 mm), 2” (51 mm), 2-1/2” (63.5 mm) and 3”
The material shall meet the requirements of (76.2 mm).
ASTM Specification C-892-85, Gr. 4, 6 and 8,
with the following additional requirements: Material may also be purchased in
widths of 4’-0” (1220 mm) and 25’-0”
2.1 Where the provisions of this (7620 mm) long. Special lengths may be
Specification do not agree with ASTM purchased, such as, 4’-0” (1220 mm), 8’-0”
Specification C-892-85, Gr. 4, 6 and 8, the (2440 mm), etc.
provisions of this Specification shall govern.
4.2 Density
2.2 LT type material shall be used on
surfaces operating at temperatures up to Density of material shall be as
1900o F (1038o C). RT and HP type shall be used follows:
on surfaces operating at temperatures up to
2250o F (1232o C). HT type shall be used on Grade Nominal Density lbs/ft3 (Kg/m3)
surfaces operating at temperatures up to 4 4 (64) + 30%, -15%
2550o F (1400o C). HP type shall be used on 6 6 (96) + 30%, -15%
surfaces where requirements of reducing 8 8 (128) + 30%, -15%
conditions of low alkali, low iron, or low titanium
are to be met.
LT, RT, HP 4 4 (64) 0.496 (0.072) 0.79 (0.114) 1.02 (0.147) 1.39 (0.201)
LT, RT, HP, HT 6 6 (96) 0.435 (0.063) 0.72 (0.104) 0.90 (0.130) 1.14 (0.165)
LT, RT, HP, HT 8 8 (128) 0.416 (0.060) 0.68 (0.098) 0.85 (0.123) 0.95 (0.137)
Fiber Index shall have a maximum shot content of 30% by weight as tested by ASTM C892,
Annex A2.
LT,RT,HP 4 3 (21)
6 6 (42)
8 8 (55)
HT 4 2 (14)
6 4 (28)
8 6 (42)
7.0 Warranty