Professional Documents
Culture Documents
Series FV: Cantilever Sump Pumps
Series FV: Cantilever Sump Pumps
Highest reliability:
can run dry and can
handle liquids con-
taining solids.
No bearings in
the liquid
No shaft seal
Clogless
1.1017 GB 01.02
Series FV
Clogless
Vortex impellers are used, permitting
easy passage of large solids through
the pumps without risk of blockage.
Low Power
Consumption
Efficiencies of the FV pumps are
higher than for other vortex pumps,
due to the new impeller design. The
result is lower operating costs.
Maintenance
= Lubrication only
The only maintenance needed is
bearing lubrication. Pump casings, The left side of the figure
impellers, bearings and impeller shows the version with a
fittings are part of the ABS Modular fully protected shaft.
SystemTM. Stocks of replacement parts
are therefore minimized.
For Highly
Aggressive
Liquids
The pumps are available in corrosion
resistant alloys and the shaft is then
protected by a sealed sleeve over its
entire length.
Series FV
Design
These pumps fulfill the applicable The bearing assembly contains a pair
quality requirements in ISO 5199.
Shaft and Bearings of opposed angular contact ball bea-rings
There are three bearings in the rigid
and a roller bearing. Grease lubrication
bearing arrangement - above the
Pump Casing mounting plate. Because none of the
is used and the bearings are protected
Casing and casing covers are the same by an effective sealing arrangement. B10
bearings are in the liquid and there is no
as used in Series FB - our horizontal bearing life exceeds 40,000 hours -
shaft seal, the primary causes of
clogless pumps. equivalent to 5 years continuous service
operational failures in submerged canti-
The pump casing is fixed to the sup- - calculated for the extreme
lever pumps have been eliminated.
port tube, which is suspended from the recommended duty, i.e. liquid S.G 1.8
bearing bracket, the latter being and pump speed 1800 r/min.
supported by the mounting plate.
The vortex impeller ensures a clear
flow-path through the casing for solids.
No shaft seal is required behind the
impeller, but leakage along the shaft at
this position is limited by a ”throttling”
volume between the shaft sleeve and a
bush fitted in the casing cover.
Impeller
As with the casings and covers, the vortex
impellers are those used in FB-Series
pumps. They are of semi-open design, eli- The finite element method has been used to check
minating all clogging risks, and have that the adequate rigidity has been achieved in the
backvanes to reduce axial thrust. design.
1450 r/min
*) FV 100/100-32 and larger sizes are also 50
available with impeller of cast iron 0120. 50/50-20
40
2900 r/min
Max. setting
30 depth 1m
Technical Data 20
100/100-32
Capacity 3-600 m /h
3 50/50-26
150/150-32
Head 5-65 m
Temperature Max. 220°C 80/80-26 200/200-32
Flange ISO 7005 PN 10 10
50/50-20
Lubrication Grease
Setting depth Max. 2* m
*) Can be increased by 1 m by fitting an
extension pipe to the inlet. 5
3 4 5 10 20 30 40 50 100 200 300 400 500 m3/h
Series FV
Dimensions
y1
x
lb
200 DN2
v1
Z
20
40
lp
DN1
max 1000
min 100
lp