Point of ● Run CPU ● DI120-240

TCD - 214 HLON Fault (One or More ) Application


Detection ○ Speed CPU ● DI180-420

[Meaning] When at least one HLON board communication is failed. [Actions to take]

1. Check errors for the SIDE, calling chime, and floor HLON
board communication by means of ANN - A21E(Back-up
Ram Referring Mode).
[Explanation] ※ Example
Enter the followings on ANN board.
Group_Net_Err_Status->Node[fl_side][call_type][fl_zone] TCD 214 K: A21E
ADDR:DAT K : 1040E
0x1040
If 1040=x02(0000 0010),
SIDE1,K-type calling, absolute floor 2nd floor HLON
※ CNL(C-NET LON) sends the results of communication with HLON on each HALL side to 1960 through board fault.
DPRAM, and 1960 checks the HLON board responding status by referring HALL installation SPEC and
If 1040=x30(0011 0000),
stores them by bit. The variable is Group_Net_Err_Status->Node[fl_side][I][fl_zon] (0x1040).
HALL HLON board for each corresponding Bit is as shown below. The HLON is normal if the bit is ‘0’ and SIDE1,K-type calling, absolute floor 5,6th floor button
the HLON is abnormal if the bit is ‘1’. board fault.
Group_Net_Err_Status->Node[fl_side][call_type][fl_zone]
To see 8th or higher floor, enter KEY-PAD ‘0’(INC) on the
ANN board.
Side Side1 Side2 2. Check the failed floor for DHL-2XX board LED-LD1 flickering
Calling Floor Address Floor Address status.
57~64 Floor 0x1060 57~64 Floor 0x1080 (Normally, at 300ms interval)
N
type ∫ ∫ ∫ ∫ 3. Verify that connectors for G-NET LON are connected well.
1~8 Floor 0x1059 1~8 Floor 0x1079 4. Check the voltage between No. 4 and 3 pin plug of DHL-2XX
57~64 Floor 0x1058 57~64 Floor 0x1078 board HA of the failed floor. (DC22V)
M
type ∫ ∫ ∫ ∫ 5. Check the terminal resistance(DIP SW No.14) setting of
1~8 Floor 0x1051 1~8 Floor 0x1071 DHL-2XX board on the failed side.
57~64 Floor 0x1050 57~64 Floor 0x1070 (Refer to terminal resistance setting criteria)
L
∫ ∫ ∫ ∫ 6. Check the DHL-2XX board side, calling chime, and floor ID of the
type
1~8 Floor 0x1049 1~8 Floor 0x1069 failed floor. (Refer to HALL ID setting criteria)
57~64 Floor 0x1048 57~64 Floor 0x1068 7. Measure the resistance between No. 1 and 2 pin of DHL-2XX
K
type ∫ ∫ ∫ ∫ board HA connector of the failed floor. If the resistance value
1~8 Floor 0x1040 1~8 Floor 0x1061 is beyond 6 ±0.5 Ohm, pulse transformer(PST) is judged to
be bad.
8. Replace DOC-U50 ROM of DOC-200.
[Symptoms]
9. Replace DHL-U2 ROM in DHL-2XX of the failed floor.
•LED-LD1 in DHL-2XX board on the side of the HALL does not flicker at 300ms interval.
• All output reset, input, or output control is impossible on the side of the HALL.