DS Series - Flue Clearances

50mm clearance to a
combustible material

combustible framing
member or joinery
unit panel

25mm minimum
insulating board
50 min

exhaust flue behind


intake flue
40

110 OD
876 overall of FL with flue clearance

80 OD
overhang of exhaust
flue above line of fire
chassis

intake flexible flue

exhaust and intake


flue spigots

height from base of fire


to underside of
combustible material

DS Series Gas FIre


Top Clearance 1:5

Applicable for:
DS1150
DS1400
DS1650

notes:
· DO NOT SCALE OFF THESE DRAWINGS. All dimensions are in mm.
· This detail is to assist in the installation the DS Series Gas Fire.
· Wall board can be bonded directly to the faces of the appliance using construction adhesive. Screw fixing of wall board
only, in to wall lining fixing bracket above the glass opening.
· In hutch style, sealed cavity or units with a low top above a DS Series Fire, Escea strongly recommends the installation of an
insulating board to the underside of the top surface. This will assist in protecting heat sensitive surfaces from damage over
time. Refer to the DS Series Sealed Cavity Design Guide.
· It is advisable to secure the flexible flue to prevent movement, vibration and sagging - this may also assist in maintaining the
required 50mm standoff.
· 50mm clearance to all combustible surfaces for the first 1200mm of the exhaust flue - zero clearance beyond this point.
· Escea recommends calcium mineral boards for their insulating and heat resistant properties. Refer to the D-Series Materials
Guide for information on insulating boards.
· This technical sheet must be read in conjunction with the Escea DS Series Installation Manual, the latest version can be
found on our website at www.escea.com

GENERAL CONSTRUCTION AND FINISHES SHOWN INDICATIVE ONLY

Contact the ESCEA Architectural Advisory Team for assistance with the specification of this fire - aa@escea.com

DS_Install_Flue Clearance.dwg 30.11.2020


DS Series - Flue Clearances

50 min 50mm clearance to a


combustible material

25mm minimum
insulating board
110 OD

80 OD

- where adjacent
to flue pipes
155

intake flexible flue


943 overall from base of the appliance

exhaust flue behind


intake flue
788 appliance height

exhaust and intake


flue spigots

combustible framing
member or joinery
unit panel

DS Series Gas FIre

25

50

Side Clearance 1:5

Applicable for:
DS1150
DS1400
DS1650

notes:
· DO NOT SCALE OFF THESE DRAWINGS. All dimensions are in mm.
· This detail is to assist in the installation the DS Series Gas Fire.
· Wall board can be bonded directly to the faces of the appliance using construction adhesive. Screw fixing of wall board
only, in to wall lining fixing bracket above the glass opening.
· In hutch style, sealed cavity or units with a low top above a DS Series Fire, Escea strongly recommends the installation of an
insulating board to the underside of the top surface. This will assist in protecting heat sensitive surfaces from damage over
time. Refer to the DS Series Sealed Cavity Design Guide.
· It is advisable to secure the flexible flue to prevent movement, vibration and sagging - this may also assist in maintaining the
required 50mm standoff.
· 50mm clearance to all combustible surfaces for the first 1200mm of the exhaust flue - zero clearance beyond this point.
· Escea recommends calcium mineral boards for their insulating and heat resistant properties. Refer to the D-Series Materials
Guide for information on insulating boards.
· This technical sheet must be read in conjunction with the Escea DS Series Installation Manual, the latest version can be
found on our website at www.escea.com

GENERAL CONSTRUCTION AND FINISHES SHOWN INDICATIVE ONLY

Contact the ESCEA Architectural Advisory Team for assistance with the specification of this fire - aa@escea.com

DS_Install_Flue Clearance.dwg 30.11.2020