Air-Cooled

Chillers
operation was matter of survival, the only
Low-Sound acceptable mechanical designs were
Engineering selected using YORK’s “low sound”
engineered equipment. These same YORK
Quiet performance in air-cooled chillers technologies have been used to provide “low
is critical in many commercial, industrial and sound” commercial chillers, which customers
institutional installations. To meet this are demanding.
®
requirement, YORK offers a wide range In-depth experience, careful materials
of proven sound-attenuation technologies selection and innovative design — exemplified
for our air-cooled chiller line. by our HCFC-22 and HFC-407C Eco 2
“Low sound” is the direct result of intelligent chillers — are your assurance that YORK
engineering. YORK has achieved this advanced systems can provide low-sound and
technology through intense laboratory examin- environmentally safe performance.
ation of equipment acoustics and vibrations. To hear how we can meet sound levels
This extensive knowledge and expertise required in your application, call your
allows YORK to provide quiet equipment to nearest YORK sales representative
the United States Navy. When quiet submarine for model ratings engineered options.

Our Features, Your Benefits

Air management
with specially matched
fan motor/fan blade
sets, positioned
within partitioned
condenser sections for
control over the sound
of discharged air

Compressor isolation
using resilient elastomers
under compressor feet
minimizes vibration
transmitted into the
On screw chillers, main unit frame enhancing
Screw chillers include discharge gas lines between low sound characteristics
an acoustically tuned the compressor and oil
internal muffler matched separator are fitted with a
to the compressor for specially formulated, high-
greater sound attenuation density, inorganic polymeric
by harnessing discharge material that dampens
gas pulsations sound transmission
Sound Attenuation Options
Low-Sound Fans Compressor Blanket
In place of standard speed Fitted in two pieces around
fan motors, lower-speed fan the compressor with Velcro
motors can be specified to seams for easy serviceability.
minimize sounds caused Polyester material: high tensile
by air traveling through the strength, both UV and
condenser section coils. mildew protected, waterproof,
Regular motors and pitched rip-resistant and fire-resistant
fan blades can be replaced (meeting State of California
FACTORY-MOUNTED with steeper pitched blades FACTORY- OR FIELD- Fire Marshall flame
OPTION and matched lower RPM MOUNTED OPTION specifications). Easily
motors to provide the cleanable with soap and water.
required airflow volume.

Screw Compressor
Attenuation
Compressor Condenser
Attenuation
Condenser
Heavy-gauge, galvanized- Baffle
The aerodynamic neutral
steel baffles are field zone of the “W” section of
installed around the lower each fan cell is baffled by
Perimeter
half of the chiller and epoxy- Attenuators specially formulated,
painted to match the unit’s inorganic-spun fiber that
FACTORY-MOUNTED color. The baffle design FACTORY-MOUNTED is inert and non-flame
OPTION facilitates air flow through OPTION propagating. (The same
the compressor section material is used in compressor
while blocking sound perimeter baffling.)
emissions and allowing easy
removal for service access.

Typical Installations
Elementary School, Library, Michigan
Pennsylvania Books require temperature
Sited in a residential and humidity control; people
community, this 400-student require comfort and quiet —
school uses a 200-ton low- both are achieved by a 150-
sound unit to maintain ton YORK chiller in this
indoor comfort and an ideal library application.
learning environment. Its
quiet operation blends with
the neighborhood by
preventing noise from being
heard by nearby residents.

P.O. Box 1592, York, Pennsylvania USA 17405-1592 Tele. 800-861-1001 Subject to change without notice. Printed in USA
© 2003 YORK International Corporation www.york.com ALL RIGHTS RESERVED