VSP152...

SBM technology
40 bar check valve
G 1/4 ... G 1 1/4

Robust, compact & lightweight design


Proven & reliable technology (no spring)
Maintenance free
Corrosion resistant design

Technical features
Medium: Maintenance free life time: Fluid/Ambient temperature: Materials
Compressed air, 40 μm filtered, Typically exceeds 25 +10 ... +50°C max. (Ambient) Housing and covers: Aluminium
non-lubricated Million cycles 0 ... +50°C max. (Fluid) anodised
Pre-lubrication of the static Operating pressure: Air supply must be dry enough Valve piston: FDA compliant
sealing: 3 ... 40 bar to avoid ice formation at synthetic material
USDA H1 compliant Port size: temperatures below +2°C O-ring: NBR
(registered NSF class H1) G 1/4 ... G 1 1/4
Operation: Mounting:
Check Valve (no spring) Line mounted

Technical data, standard models


Symbol Port size Nominal Ø Kv Weight Model
(mm) (m3/h) (kg)
G1⁄4 8 1,2 0,04 VSP152226
G3⁄8 10 1,9 0,07 VSP152227
G1⁄2 13 3,2 0,17 VSP152035
1 2
G3/4 19 6,7 0,29 VSP152036
G1 25 10,0 0,64 VSP152037
G1 1/4 31 18,0 0,78 VSP152038

Options selector VSP152˙˙˙

Port size Substitute


G1/4 226
G3/8 227
G1/2 035
G3/4 036
G1 037
G1 1/4 038

4/13 Our policy is one of continued research and development. We therefore reserve the right to amend, N/en 5.10.363.01
without notice, the specifications given in this document.
VSP152...

Dimensions
G1/4 & G3/8

1 2

B
B
D
G1/2 ... G1 1/4
C

1 2
B

Port size C ØD Model


B
G1⁄4 50 24 21 VSP152226
G3⁄8 60 29 26 VSP152227
G1⁄2 77 39 34 VSP152035
G3/4 87 49 41 VSP152036
G1 110 64 55 VSP152037
G1 1/4 135 69 60 VSP152038

Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes
systems only. Do not use these products where pressures and of all component parts used in pneumatic systems and to provide
temperatures can exceed those listed under »Technical features«. adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in
for non-industrial applications, life-support systems, or other ap- the system instructional manual if protection against
plications not within published specifications, consult NORGREN. a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with
fluid power systems can fail in various modes. these products.

N/en 5.10.363.02 Our policy is one of continued research and development. We therefore reserve the right to amend, 4/13
without notice, the specifications given in this document.