TROUBLESHOOTING _ DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE + Governor control system 1 Check input signal 1) Check fuel control dial input voltage i) Set to the monitoring mode, and display monitoring code 30. ii) Measure the voltage when the fuel control dial is turned from low idling to high idling Voltage: 0.25 - 4.75 V 2) Check governor potentiometer voltage i) Set to the monitoring mode, and display monitoring code 31 ii) Measure the potentiometer voltage when the fuel contro! dial is turned from low idling to high idling. * Voltage: 0.5 ~ 4.2 V lauto-decle at OFF) Check output signal 1) Check governor motor drive current i) Set to the monitoring mode, and display monitoring codes 33 and 34. ‘%* Code 33 is the A phase and code 34 is the B phase ii) Measure the governor motor drive current when the fuel control dial is turned in the acceleration direction and deceleration direction. * Current: 700 + 70 (mA) 2) Measure battery relay drive output voltage i) Set to the monitoring mode, and display monitoring code 35. ii) Measure the battery relay drive output voltage when the starting switch is turned from ON to OFF. or iii) Set to the monitoring mode, and display monitoring code 37. iv) Check that bit (1) lights up when the starting switch is turned from ON to OFF. 20-254 02006