Professional Documents
Culture Documents
Matrix 424 832 832+: ICON Programming Manual
Matrix 424 832 832+: ICON Programming Manual
EN50131-1
Security Grade 2
RINS917-4 Environmental Class 2
Pyronix Installers Club (PI Club)
Installer Support
The PI Club has been developed with the focus on what you the installer would like to see from
one of the world’s leading manufactures of security equipment.
The philosophy behind the association is that you will receive tangible benefits, which are
applicable to both the work and home environment.
Dedicated Website
You will have access to a dedicated PI Club section of the Pyronix website which is packed full of
features that will keep you updated on Pyronix and industry news.
To Join the PI Club please register at www.pyronix.com, or for further information please contact
our marketing department at marketing@pyronix.com.
As a new member of the PI Club a technical help free phone number will be issued to you.
Matrix 424/832/832+ ICON Programming Guide
CONTENTS
1. ENTERING / EXITING ENGINEER MODE AND CHANGE ENGINEER CODE ...................................................1
2. SYSTEM OPTIONS PROGRAMMING..........................................................................................................1
3. ZONE CONFIGURATION ..........................................................................................................................2
3.1 Zone Connections ...............................................................................................................................2
3.2 Zone Type – Arm Mode A ....................................................................................................................3
3.3 Zone Type – Arm Mode B ....................................................................................................................4
3.4 Zone Type – Arm Mode C ....................................................................................................................5
3.5 Zone Type – Arm Mode D....................................................................................................................6
3.6 Zone Attributes – Arm Mode A, B, C and D ...........................................................................................7
3.7 Assigning Zones to Partitions .............................................................................................................12
3.8 Copy Arm Mode A to Modes B, C & D .................................................................................................13
4. USER CODES........................................................................................................................................14
4.1 Assigning User Codes to Partitions .....................................................................................................14
4.2 User Code Attributes .........................................................................................................................18
4.3 Temporary Code ...............................................................................................................................26
5. REMOTE KEYPAD PARAMETERS ............................................................................................................28
5.1 ICON Keypad Partition Allocation .......................................................................................................28
5.2 ICON Keypad Private / Public Mode....................................................................................................28
5.3 LCD Keypad Partition Allocation .........................................................................................................28
5.4 LCD Keypad Private / Public Mode......................................................................................................28
5.5 Proximity Reader Partition Allocation ..................................................................................................29
5.6 Proximity Reader Private / Public Mode ..............................................................................................29
6. FAULTS................................................................................................................................................29
6.1 System Fault Partition Allocation ........................................................................................................29
6.2 Bell/Tamper Fault Partition Allocation .................................................................................................29
7. PARTITION OPTIONS ...........................................................................................................................30
7.1 Partition Options 1 ............................................................................................................................30
7.2 Partition Options 2 ............................................................................................................................31
8. ARM OPTIONS......................................................................................................................................33
8.1 Exit Terminator .................................................................................................................................33
8.2 Home and Away Allocation ................................................................................................................34
8.3 Partition Dependency ........................................................................................................................34
8.4 Keyswitch Zone Arm Configuration.....................................................................................................35
8.5 Number of Re-Arms ..........................................................................................................................35
9. SYSTEM TIMERS ..................................................................................................................................36
10. OUTPUTS ...........................................................................................................................................37
10.1 Zone To Follow ...............................................................................................................................37
10.2 Output Types ..................................................................................................................................38
10.3 PGM Polarity ...................................................................................................................................39
11. COMMUNICATOR OPTIONS .................................................................................................................40
11.1 Account Code..................................................................................................................................40
11.2 Up/Downloading Code .....................................................................................................................40
11.3 Telephone Line Options ...................................................................................................................40
11.4 Test Dial Time.................................................................................................................................41
11.5 Test Dial Interval ............................................................................................................................41
11.6 Telephone Number Allocation ..........................................................................................................41
11.7 Test Dial Sequence..........................................................................................................................41
11.8 Anti-Code Algorithm ........................................................................................................................41
11.9 Number of Voice Message Dials .......................................................................................................41
12. FORMATS...........................................................................................................................................42
12.1 Telephone Number..........................................................................................................................42
RINS917-4 Page i
Matrix 424/832/832+ ICON Programming Guide
12.2 Reporting Formats Allocation ...........................................................................................................42
12.3 BSIA Format Channel Map ...............................................................................................................42
13. SEND OPTIONS ..................................................................................................................................43
13.1 Send Options ..................................................................................................................................43
13.2 Telephone Dial Sequence.................................................................................................................51
13.3 Voice Messages Allocation ...............................................................................................................52
14. DD243 ...............................................................................................................................................54
14.1 DD243 Options ...............................................................................................................................54
14.2 DD243 Zone Map ............................................................................................................................54
14.3 DD243 Partition Confirmation Time ..................................................................................................55
15. RADIO EXPANDER ..............................................................................................................................56
16. ENGINEER AND MAINTENANCE FUNCTIONS ........................................................................................57
16.1 Engineer Code NVM Reset ...............................................................................................................57
16.2 PGM Output Test.............................................................................................................................57
16.3 Walk Test .......................................................................................................................................57
16.4 Scan For Devices.............................................................................................................................58
16.5 Local Up/Downloading – RS232........................................................................................................58
16.6 Software Version Number ................................................................................................................58
16.7 Battery Charger Test .......................................................................................................................58
17. EVENT LOG ........................................................................................................................................59
17.1 Event Log Tables ............................................................................................................................59
18. CONTACT ID EVENT CODES ................................................................................................................62
19. QUICK REFERENCE .............................................................................................................................64
19.1 Programming Functions ...................................................................................................................64
19.2 Engineer Operations........................................................................................................................65
Page ii RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 1
Matrix 424/832/832+ ICON Programming Guide
Toggle
C System Options 3 Select Option – or > @ Save
zOFF zON
1 = Never Hide Display (Off) / Hide After 20 Seconds of Inactivity (On) C
2 = Restore Battery Faults As They Occur (Off) / When Exiting Engineer Mode (On) C
3 = Display Alarm in FTA Mode (Off) / As Alarms Occur (On) C
4 = Allow Arming During Mains Fail (Off) / Disallow (On)* C
5 = Allow Arming With Battery Fault (Off) / Disallow (On)* C
6 = Tamper On User Omitted Zones does not cause alarm (Off) / Causes Alarm (On)# C
7 = Wireless Jamming Fault when armed does not cause tamper (Off) / Causes tamper (On) C
8 = Allow Wireless keyfob disarm during entry period only (Off) / Always (On) C
(Off) / (On) = Default
*NOTE: Belgium - This option MUST be set to “Disallow” to comply with T014.
#NOTE: Belgium - This option MUST be set to “Causes Alarm” to comply with T014.
3. ZONE CONFIGURATION
Option 6 will be set to YES and disabled from the system completely.
Page 2 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Zones 33-64 are only available when Zone Doubling is enabled see Function 250
C |0| |5| |__| |__| C 02 C |3| |7| |__| |__| C 02
C |0| |6| |__| |__| C 02 C |3| |8| |__| |__| C 02
C |0| |7| |__| |__| C 02 C |3| |9| |__| |__| C 02
C |0| |8| |__| |__| C 02 C |4| |0| |__| |__| C 02
C |0| |9| |__| |__| C 02 C |4| |1| |__| |__| C 02
RINS917-4 Page 3
Matrix 424/832/832+ ICON Programming Guide
Zones 33-64 are only available when Zone Doubling is enabled see Function 250
C |0| |5| |__| |__| C 02 C |3| |7| |__| |__| C 02
C |0| |6| |__| |__| C 02 C |3| |8| |__| |__| C 02
C |0| |7| |__| |__| C 02 C |3| |9| |__| |__| C 02
C |0| |8| |__| |__| C 02 C |4| |0| |__| |__| C 02
C |0| |9| |__| |__| C 02 C |4| |1| |__| |__| C 02
Page 4 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Zones 33-64 are only available when Zone Doubling is enabled see Function 250
C |0| |5| |__| |__| C 02 C |3| |7| |__| |__| C 02
C |0| |6| |__| |__| C 02 C |3| |8| |__| |__| C 02
C |0| |7| |__| |__| C 02 C |3| |9| |__| |__| C 02
C |0| |8| |__| |__| C 02 C |4| |0| |__| |__| C 02
C |0| |9| |__| |__| C 02 C |4| |1| |__| |__| C 02
RINS917-4 Page 5
Matrix 424/832/832+ ICON Programming Guide
Zones 33-64 are only available when Zone Doubling is enabled see Function 250
C |0| |5| |__| |__| C 02 C |3| |7| |__| |__| C 02
C |0| |6| |__| |__| C 02 C |3| |8| |__| |__| C 02
C |0| |7| |__| |__| C 02 C |3| |9| |__| |__| C 02
C |0| |8| |__| |__| C 02 C |4| |0| |__| |__| C 02
C |0| |9| |__| |__| C 02 C |4| |1| |__| |__| C 02
Page 6 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |0| |1| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0| |2| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0| |3| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0| |4| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0| |5| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0||6| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
RINS917-4 Page 7
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |0||7| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0||8| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |0||9| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||0| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||1| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||2| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
Page 8 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |1||3| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||4| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||5| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||6| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||7| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |1||8| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
RINS917-4 Page 9
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |1||9| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||0| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||1| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||2| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||3| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||4| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
Page 10 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |2||5| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||6| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||7| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||8| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |2||9| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |3||0| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
RINS917-4 Page 11
Matrix 424/832/832+ ICON Programming Guide
Arm Toggle
Function Zone Select Option – or > @
Mode zOFF zON Save
C A |3||1| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
C A |3||2| 1 = Chime Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C B 2 = Test Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C C 3 = Mask Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
C D 4 = Double Knock Disabled (Off) / Enabled (On) A= B = C= D = A = B = C= D= C
5 = Zone Polarity Normally Closed (Off) / Normally Open (On) A= B = C= D = A = B = C= D= C
(Off) / (On) = Default
Page 12 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 13
Matrix 424/832/832+ ICON Programming Guide
4. USER CODES
Page 14 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |0| |8| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |0| |9| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |0| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |1| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |2| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |3| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |4| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |5| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
RINS917-4 Page 15
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |1| |6| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |7| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |8| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |1| |9| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |0| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |1| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |2| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |3| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
Page 16 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |2| |4| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |5| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |6| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |7| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |8| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |2| |9| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |3| |0| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
C |3| |1| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
RINS917-4 Page 17
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |3| |2| 1 = Not Assigned to Partition 1 (Off) / Assigned (On) C
2 = Not Assigned to Partition 2 (Off) / Assigned (On) C
3 = Not Assigned to Partition 3 (Off) / Assigned (On) C
4 = Not Assigned to Partition 4 (Off) / Assigned (On) C
(Off) / (On)
= Default
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |0| |1| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On). C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |2| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
Page 18 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |0| |3| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |4| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |5| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |6| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
RINS917-4 Page 19
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |0| |7| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |8| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |0| |9| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |0| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
Page 20 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |1| |1| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |2| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |3| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |4| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
RINS917-4 Page 21
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |1| |5| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |6| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |7| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |1| |8| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
Page 22 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |1| |9| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |0| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |1| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |2| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
RINS917-4 Page 23
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |2| |3| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |4| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |5| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |6| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
Page 24 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |2| |7| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |8| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |2| |9| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |3| |0| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
RINS917-4 Page 25
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function User Select Option – or > @ Save
zOFF zON
C |3| |1| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
C |3| |2| 1 = Do Not Allow Omit (Bypass) Zones (Off) / Allow (On) C
2 = Normal User Code (Off) / Duress Code Only (On) C
3 = Duress Code Disabled (Off) / Enabled (On) C
4 = Do Not Allow Arm (Off) / Allow Arm (On) C
5 = Do Not Allow Disarm (Off) / Allow Disarm (On) C
6 = Forced Rearm Disabled (Off) / Enabled (On) C
7 = Reserved For Future Use. Do Not Change. C
8 = Limited User Code (Off) / Master User Code (On) C
(Off) / (On) =
Default
Page 26 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 27
Matrix 424/832/832+ ICON Programming Guide
Page 28 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
6. FAULTS
*NOTE: Entering 0 as the partition will assign the keypad to ALL partitions.
RINS917-4 Page 29
Matrix 424/832/832+ ICON Programming Guide
7. PARTITION OPTIONS
Page 30 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Partition Options 1 Partition Select Option – or > @ Save
zOFF zON
|4| 1 = Audible PA Alarm (Off) / Silent PA Alarm (On) C
2 = Reserved For Future Use. Do Not Use. C
3 = Internal Sirens Only on Tamper (Off) / Internal and External (On) C
4 = Do Not Display Open Zones When Disarmed (Off) / Display Open Zones (On) C
5 = Do Not Omit (Bypass) Open Zones on Rearm (Off) / Omit Open Zones (On) C
6 = Bell Squawk Off (Off) / Bell Squawk On (On) C
7 = “Kiss-Off” Confirmation Tone Off (Off) / Confirmation Tone On (On) C
8 = Do Not Display Open Zones in Alarm (Off) / Display Open Zones in Alarm (On) C
(Off) / (On) = Default
RINS917-4 Page 31
Matrix 424/832/832+ ICON Programming Guide
*IMPORTANT NOTE
If the below options are both turned ON; an Engineer Reset is only needed for any TAMPER ALARMS.
A user code will be able to reset ALL OTHER ALARMS.
FUNCTION 401
OPTION NUMBER 3 ON = ENGINEER RESET ENABLED
OPTION NUMBER 4 ON = RESET REQUIRED AFTER ALL ALARMS
Page 32 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
8. ARM OPTIONS
Note: If the wireless function ‘quick arm’ is used then the exit timer is suspended. If the user doesn’t want the exit timer to be suspended on
an open zone in silent set then the key fob must not use the quick arm option. The normal timed arm option should be used with a long exit
timer.
RINS917-4 Page 33
Matrix 424/832/832+ ICON Programming Guide
Page 34 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
Function Partition Select Option – or > @ Save
zOFF zON
C |3| 1 = Partition Will Not Arm with Partition 1 (Off) / Partition Will Arm with Partition 1 (On) C
2 = Partition Will Not Arm with Partition 2 (Off) / Partition Will Arm with Partition 2 (On) C
3 = Partition Will Not Arm with Partition 3 (Off) / Partition Will Arm with Partition 3 (On) C
4 = Partition Will Not Arm with Partition 4 (Off) / Partition Will Arm with Partition 4 (On) C
C |4| 1 = Partition Will Not Arm with Partition 1 (Off) / Partition Will Arm with Partition 1 (On) C
2 = Partition Will Not Arm with Partition 2 (Off) / Partition Will Arm with Partition 2 (On) C
3 = Partition Will Not Arm with Partition 3 (Off) / Partition Will Arm with Partition 3 (On) C
4 = Partition Will Not Arm with Partition 4 (Off) / Partition Will Arm with Partition 4 (On) C
(Off) / (On) =
Default
RINS917-4 Page 35
Matrix 424/832/832+ ICON Programming Guide
9. SYSTEM TIMERS
Function Timer Partition Time Save Default Key
C Bell Time |1| |__| |__| C 4 00..99 = Time in Minutes
C Bell Time |2| |__| |__| C 4
C Bell Time |3| |__| |__| C 4
C Bell Time |4| |__| |__| C 4
C Bell Delay |1| |__| |__| C 00 00..99 = Time in Minutes
C Bell Delay |2| |__| |__| C 00
C Bell Delay |3| |__| |__| C 00
C Bell Delay |4| |__| |__| C 00
NOTE – Italy: Bell Delay MUST be set to 0 to comply with CEI79.
C Entry Time |1| |__| |__| C 20 00..99 = Time in Seconds
C Entry Time |2| |__| |__| C 20
C Entry Time |3| |__| |__| C 20
C Entry Time |4| |__| |__| C 20
C Exit Time |1| |__| |__| C 20 00..99 = Time in Seconds
C Exit Time |2| |__| |__| C 20
C Exit Time |3| |__| |__| C 20
C Exit Time |4| |__| |__| C 20
C Final Exit Delay |1| |__| |__| C 07 00..99 = Time in Seconds
C Final Exit Delay |2| |__| |__| C 07
C Final Exit Delay |3| |__| |__| C 07
C Final Exit Delay |4| |__| |__| C 07
C Auto Arm Commencing Time |1| |__| |__| |__| |__| C 0000 0000..2359 = Time (0000 = Disabled)
C Auto Arm Commencing Time |2| |__| |__| |__| |__| C 0000
C Auto Arm Commencing Time |3| |__| |__| |__| |__| C 0000
C Auto Arm Commencing Time |4| |__| |__| |__| |__| C 0000
NOTE: Italy - If Auto Arm is to be used, Allow Arm if H,I,P,F,M,T Zones Open must be set to “Yes” and Immediate Zones Open on Exit must be
set to “Causes an Alarm” (System Options 2) in order to comply with CEI79.
Page 36 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
10. OUTPUTS
RINS917-4 Page 37
Matrix 424/832/832+ ICON Programming Guide
OUTPUT TYPES
00 Not USed 12 Follow Confirmed Alarm 24 Follow Digital Output Confirmed 36 Follow Momentary Burglary
01 E- LED Enable 13 Follow Tamper Alarm 25 Follow Digital Output Omit 37 Follow Momentary 24HR
02 C+ Latch 14 External Bell 26 Follow Hidden Display 38 Follow Momentary Fire
03 RKP Controlled 15 GND Fire Detector (PGM4 only) 27 Follow Mains Fail 39 Follow Momentary Medical
04 Follow Arm/Disarm 16 Twin Alert (PGM3 only) 28 Follow Battery Low 40 Follow Momentary PA
05 Follow Zone 17 Follow Entry/Exit 29 Follow Battery Missing 41 Follow Momentary Tamper
06 Follow Tel Line Fail 18 Follow Digital Output Fire 30 Internal Sounder 42 Follow Momentary Duress
07 Follow Kiss Off 19 Follow Digital Output PA 31 Follow Medical Alarm 43 Follow Momentary ComFail
08 Shock/Fire Sensor Reset 20 Follow Digital Output Intruder 32 Follow Battery Faults 44 Follow Momentary RKP Fail
09 Follow Strobe 21 Follow Digital Output Open/Close 33 Follow Duress 45 Follow Momentary Test Call
10 Follow Fire Alarm 22 Follow Digital Output Abort 34 Follow Disarmed 46 Status LED Output
11 Follow PA Alarm 23 Follow Digital Output Medial 35 Follow System Faults 47 Keyfob Controlled
48 Follow Supervision Timer
Page 38 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 39
Matrix 424/832/832+ ICON Programming Guide
Page 40 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 41
Matrix 424/832/832+ ICON Programming Guide
12. FORMATS
Page 42 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 43
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Disarmed Mode Send Options Partition Select Option – or > @ Save
zOFF zON
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
Page 44 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Arm Mode A Send Options Partition Select Option – or > @ Save
zOFF zON
|3| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
RINS917-4 Page 45
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Arm Mode B Send Options Partition Select Option – or > @ Save
zOFF zON
|2| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|3| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
Page 46 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 47
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Arm Mode C Send Options Partition Select Option – or > @ Save
zOFF zON
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
Page 48 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Arm Mode D Send Options Partition Select Option – or > @ Save
zOFF zON
|3| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
RINS917-4 Page 49
Matrix 424/832/832+ ICON Programming Guide
Toggle
C Restoral Send Options Partition Select Option – or > @ Save
zOFF zON
|2| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|3| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
|4| 1 = Intruder Events Not Sent (Off) / Sent (On) C
2 = Panic Alarm Events Not Sent (Off) / Sent (On) C
3 = Fire Alarm Events Not Sent (Off) / Sent (On) C
4 = Maintenance Events Not Sent (Off) / Sent (On) C
5 = Open/Close Events Not Sent (Off) / Sent (On) C
6 = Medical Alarm Events Not Sent (Off) / Sent (On) C
7 = Confirmed Alarm Events Not Sent (Off) / Sent (On) C
8 = Omits (Bypass) Events Not Sent (Off) / Sent (On)* C
(Off) / (On) = Default
*NOTE: Italy - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with CEI79.
Belgium - Omit (Bypass) Events MUST be reported for all Arm Modes to comply with T014.
Page 50 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 51
Matrix 424/832/832+ ICON Programming Guide
Function Part’n Alarm Type Tel 1 Save Tel 2 Save Tel 3 Save Default
C |4| |1| (Intruder Events) |__| C |__| C |__| C 1, 2, 0
C |4| |2| (Personal Attack Events) |__| C |__| C |__| C 1, 2, 0
C |4| |3| (Fire Alarm Events) |__| C |__| C |__| C 1, 2, 0
C |4| |4| (Maintenance Events) |__| C |__| C |__| C 1, 2, 0
C |4| |5| (Open/Close Events) |__| C |__| C |__| C 1, 2, 0
C |4| |6| (Medical Alarm Events) |__| C |__| C |__| C 1, 2, 0
C |4| |7| (Confirmed Alarm Events) |__| C |__| C |__| C 1, 2, 0
C |4| |8| (Omit (Bypass) Events) |__| C |__| C |__| C 1, 2, 0
Page 52 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 53
Matrix 424/832/832+ ICON Programming Guide
14. DD243
Page 54 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 55
Matrix 424/832/832+ ICON Programming Guide
Page 56 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 57
Matrix 424/832/832+ ICON Programming Guide
Battery 12V
Page 58 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Page 59 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Page 60 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 61
Matrix 424/832/832+ ICON Programming Guide
18. CONTACT ID EVENT CODES
Q EEE English Equivalent Matrix System Events PP NNN
Group 1: INTRUDER ALARMS
1 or 3 130 Burglary Immediate or Access Zone – Alarm / Restoral 01-04 001-032
1 or 3 133 24 Hour 24 Hour Zone – Alarm / Restoral 01-04 001-032
1 or 3 134 Entry / Exit Entry / Exit Zone – Alarm / Restoral 01-04 001-032
1 or 3 137 Tamper Global Tamper Loop (GT Input) – Alarm / Restoral 01-04 001
1 or 3 137 Tamper Keypress Tamper – Alarm / Restoral 01-04 003
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-IX16) 01-04 002
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-RIX16 – ID1) 01-04 061
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-RIX16 – ID2) 01-04 062
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-ROX8) 01-04 041
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-LCD) 01-04 001-004
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-LCD ICON) 01-04 011-014
1 or 3 143 Expansion Module Fault Remote Device Missing / Restoral (MX-PROX) 01-04 021-024
1 or 3 144 Sensor Tamper EOL Zone – Tamper / Restoral 01-04 001-032
1 or 3 146 Silent Burglary Immediate or Access Zone – Bell Delay Alarm / Restoral 01-04 001-032
1 or 3 321 Bell Tamper Bell Tamper Loop (BT Input) – Alarm / Restoral 01-04 000
1 or 3 373 Tamper 2 Wire Fire Detector Loop (on PGM4) – Tamper / Restoral 01-04 099
1 or 3 Tamper Zone – Alarm / Restoral (Internal alarm only / no bell
383 Sensor Tamper 01-04 001-032
activation)
Group 2: PERSONAL ATTACK ALARMS
1 121 Duress Arm or Disarm by Duress User Code 01-04 001-032
1 or 3 122 Silent Panic Silent PA Alarm / Restoral from Keypad 01-04 000
1 or 3 122 Silent Panic Personal Attack Zone – Silent Alarm / Restoral 01-04 001-032
1 or 3 123 Audible Panic Audible PA Alarm / Restoral from Keypad 01-04 000
1 or 3 123 Audible Panic Personal Attack Zone – Audible Alarm / Restoral 01-04 001-032
Group 3: FIRE ALARMS
1 or 3 110 Fire Fire Alarm / Restoral from Keypad 01-04 000
1 or 3 110 Fire 2 Wire Fire Detector Loop (on PGM4) – Alarm / Restoral 01-04 099
1 or 3 110 Fire Fire Zone – Alarm / Restoral 01-04 001-032
Group 4: MAINTENANCE
1 or 3 301 AC Power AC Mains – Fail / Restoral 01 000
1 or 3 302 Low Battery Battery Missing or Low Battery – Fail / Restoral 01 000
1 305 System Reset Panel Powered Up 01 000
1 or 3 344 Jam Detect RF Expander experiencing Jamming 01-04 000
1 or 3 381 Supervision Loss Detector stopped checking in 01-04 016-032
1 or 3 384 RF Low Battery Low battery in RF detector 01-04 016-032
1 412 Successful UDL Data was successfully uploaded from / downloaded from panel 01 000
1 or 3 607 Walk Test Mode Walk Test Mode – Entered / Left 01-04 000
1 or 3 623 Event Log 90% Full Event Log 90% of Capacity 01 000
1 627 Program Mode Entry Engineer Mode Entered 01 099
1 628 Program Mode Exit Engineer Mode Left 01 099
Group 5: OPEN/CLOSE
1 or 3 401 User Open (Disarm) / Close (Arm) by User Code 01-04 001-032
1 or 3 401 User Open (Disarm) / Close (Arm) from Engineer Mode or PC 01-04 099
1 403 Automatic Open (Disarm) by Partition Dependency 01-04 000
3 403 Automatic Close (Arm) by Inactivity ot Auto Arm Timers 01-04 000
3 403 Automatic Close (Arm) On Power Up 01-04 099
1 or 3 409 Keyswitch Open (Disarm) / Close (Arm) by Keyswitch Zone 01-04 000
Group 6: MEDICAL ALARMS
1 or 3 100 Personal Emergency Medical Alarm / Restoral from Keypad 01-04 000
1 or 3 100 Personal Emergency Medical Zone – Alarm / Restoral 01-04 001-032
Group 7: CONFIRMED ALARMS
1 or 3 139 Confirmed Alarm Alarm code send after activation of any 2 zones within one arm period 01-04 000
Group 8: OMIT (BYPASS)
1 570 Zone Bypass Normal Zone Omitted (Bypassed) On Arm or Auto Rearm 01-04 001-032
1 571 Zone Bypass Fire Zone Bypasses on Arm 01-04 001-032
1 572 24 Hour Bypass 24 Hour Zone Omitted (Bypassed) On Arm or Auto Rearm 01-04 001-032
ABORT
1 406 Open After Alarm Abort / Cancel with User Code after Alarm 01-04 000
TEST DIALS
1 602 Periodic Periodic Test Call 01 000
1 or 3 250 Keybox & Patrol Keybox Zone – Opened / Closed 01-04 001-032
1 406 Open After Alarm Abort / Cancel with User Code after Alarm 01-04 000
Page 62 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
Q EEE English Equivalent Matrix System Events PP NNN
KEYBOX & PATROL
1 or 3 250 Keybox & Patrol Keybox Zone – Open (Disarm) / Close (Arm) 01-04 001-016
Message string of CID: [AAAA] [CC] [Q] [EEE] [PP] [NNN] [m]
[AAAA] Account Number
[CC] Reporting Format (18 for CID)
[Q] Event Qualifier: 1 = New Event or Opening, 3 = New Restore or Closing
[EEE] Digital Event Code
[PP] Partition Number
[NNN] Zone Number / User Number / Component Qualifier
[m] Checksum
RINS917-4 Page 63
Matrix 424/832/832+ ICON Programming Guide
19. QUICK REFERENCE
Page 64 RINS917-4
Matrix 424/832/832+ ICON Programming Guide
RINS917-4 Page 65
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, UK
Customer Support Line : +44 (0)845 6434 999 (local rate)
Or +44 (0) 1709 535225
Hours of business: 07:00 AM– 7:30 PM, Monday to Friday
email: customer.support@pyronix.com
Website: www.pyronix.com