Professional Documents
Culture Documents
Prod Spec Guide
Prod Spec Guide
SPECIFICATION
GUIDE
A CO M P R E H E N S I V E B AT T E RY
SELECTION GUIDE
PRODUCT SPECIFICATION GUIDE
The battery specifications below provide details on battery type, capacity, energy rate, terminal type, dimensions and weight to ensure selection of the proper battery model.
For more information on choosing the proper battery for your system type, please visit www.trojanbattery.com/tech-support/battery-maintenance/
ENERGY
CAPACITY A MINUTES CAPACITY B AMP-HOURS (Ah) DIMENSIONS C INCHES (mm) HYDROLINK™
BCI (kWh)
MODEL TERMINAL WEIGHT I LBS. OR
GROUP NAME TYPE G (kg) SINGLE-POINT
SIZE @25 @56 @75 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr LENGTH WIDTH HEIGHT F WATERING KIT H
AMPS AMPS AMPS RATE RATE RATE RATE RATE
TERMINAL TYPE
1 - ELPT 2 - EHPT 3 - EAPT 4 - EUT/R 5 - LT 6 - DT 7 - UT 8 - AP
Embedded Embedded Embedded Embedded Automotive
L-Terminal Universal Automotive Post
Low Profile High Profile Automotive Post Universal/Reverse Post & Stud
14 - IND
9 - WNT 10 - DWNT 11 - ST 12 15 - M6/M8 16 - SLT
Industrial 6mm/8mm Small
Wingnut Dual Wingnut Stud Cable & Plug Insert L-Terminal
ENERGY HYDROLINK™
BCI CAPACITY A MINUTES CAPACITY B (Ah) DIMENSIONS C INCHES (mm)
MODEL (kWh) TERMINAL WEIGHT I LBS. OR
GROUP NAME @25 @56 @75 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr TYPE G (kg) SINGLE-POINT
SIZE LENGTH WIDTH HEIGHT F
AMPS AMPS AMPS RATE RATE RATE RATE RATE WATERING KIT H
ENERGY HYDROLINK™
BCI CAPACITY A MINUTES CAPACITY B AMP-HOURS (Ah) DIMENSIONS C INCHES (mm)
MODEL (kWh) TERMINAL WEIGHT I LBS. OR
GROUP NAME @25 @56 @75 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr TYPE G (kg) SINGLE-POINT
SIZE LENGTH WIDTH HEIGHT
AMPS AMPS AMPS RATE RATE RATE RATE RATE
F
WATERING KIT H
A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a F. Dimensions taken from bottom of the battery to the highest point on the battery. Heights may vary depending on
voltage above 1.75 V/cell. Capacities are based on peak performance. type of terminal.
B. The amount of amp-hours (Ah) a battery can deliver when discharged at a constant rate at 80°F (27°C) and G. Terminal images are representative only.
* Polyon™ Case maintain a voltage above 1.75 V/cell. Capacities are based on peak performance. H. N/A = Not Available. For more information on HydroLink™ or the Single-Point Watering Kit (SPWK), please contact
C. Dimensions may vary depending on type of handle or terminal. Batteries to be mounted with .5 inches (12.7mm) your Trojan Battery representative. Gel and AGM batteries do not require watering.
spacing minimum. I. Weight may vary.
D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for
30 seconds at 0°F at a voltage above 1.2 V/cell. Trojan’s battery testing procedures adhere to both BCI and IEC test standards.
E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at ** Unavailable with T2 Technology *** Also available in 30.50
32°F at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking amps @ 32°F or M.C.A. @ 32°F.
CRANKING ENERGY HYDROLINK™
CAPACITY A MINUTES CAPACITY B AMP-HOURS (Ah) DIMENSIONS C INCHES (mm)
BCI PERFORMANCE (kWh) OR
MODEL TERMINAL WEIGHT I
GROUP SINGLE-POINT
NAME TYPE G LBS. (kg)
SIZE @25 @56 @75 C.C.A. D C.A. E 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr WATERING
LENGTH WIDTH HEIGHT F KIT H
AMPS AMPS AMPS @0°F @32°F RATE RATE RATE RATE RATE
31
OVERDRIVE 180 — — 730 875 84 93 102 112 1.34 11 12.80 (325) 6.81 (173) 9.43 (240) 67 (30) N/A
AGM 31™
921 J185-AGM 389 — 110 — — 157 171 200 212 2.54 5, 6, 15 14.97 (380) 6.94 (176) 14.45 (367) 122 (55) N/A
GC12 T1275-AGM 254 — 70 — — 114 126 132 135 1.62 5, 8, 15 12.96 (329) 7.06 (179) 10.96 (278) 83 (38) N/A
6 VOLT DUAL-PURPOSE AGM BATTERY
GC2 6V-AGM 385 — — 1100 1400 154 184 200 221 1.33 6 10.28 (261) 7.08 (180) 10.74 (273) 65 (29) N/A
12 VOLT DUAL-PURPOSE AGM BATTERY
8D 8D-AGM 460 — — 1450 1850 179 210 230 254 3.05 6 20.47 (520) 10.64 (270) 9.08 (231) 161 (73) N/A
12 VOLT DEEP-CYCLE AGM BATTERIES
GC12 12-AGM 280 — — 825 900 112 127 140 144 1.72 15 13.54 (344) 6.76 (172) 10.88 (276) 100 (45) N/A
24 24-AGM 137 — — 500 600 67 70 76 84 1.01 6 10.77 (274) 6.84 (174) 8.62 (219) 54 (24) N/A
27 27-AGM 158 — — 550 660 77 82 89 99 1.19 6 12.05 (306) 6.84 (174) 9.32 (237) 64 (29) N/A
A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for
a voltage above 1.75 V/cell. Capacities are based on peak performance. 30 seconds at 32°F at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking amps
B. T he amount of amp-hours (Ah) a battery can deliver when discharged at a constant rate at 80°F (27°C) and @ 32°F or M.C.A. @ 32°F.
* Polyon™ Case maintain a voltage above 1.75 V/cell. Capacities are based on peak performance. F. Dimensions taken from bottom of the battery to the highest point on the battery. Heights may vary depending
C. Dimensions may vary depending on type of handle or terminal. Batteries to be mounted with .5 inches on type of terminal.
(12.7mm) spacing minimum. G. Terminal images are representative only.
D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can H. N/A = Not Available. For more information on HydroLink™ or the Single-Point Watering Kit (SPWK), please
maintain for 30 seconds at 0°F at a voltage above 1.2 V/cell. contact your Trojan Battery representative. Gel and AGM batteries do not require watering.
I. Weight may vary.
Trojan’s battery testing procedures adhere to both BCI and IEC test standards.
AGM Only
TRO1043_PSG_ENG_061721