1. RLB OFFICE
RLB for Offices – Size: 15 Feet Wide X 40 Feet Long X minimum 8 Feet High
Base frame constructed by I Beam 600x200mm x11 mm size
Purling square tube 60mm x60mm x3mm (400mm Centre to Centre)
All base frames and cross beams one coat primer and two coat paint
Double layer 18mm marine plywood installed on the flooring
Over the plywood flooring 3mm thickness heavy duty PVC welded type vinyl sheet installed
Wall panel installed 100mm thick sandwich panel R20 rating
Roof panel installed 100mm thick sandwich panel with appropriated purlin R20 rating
From floor level 2.4m height 60mmx60mm fire rated ceiling tiles installed
1 mx 1m aluminum 4 Nos. windows installed in the RLB Office
2 Nos of metal door with Sargent lock, door closer, stopper installed in the RLB office
3 Nos of 2 Ton HVAC Mini split unit installed in the RLB office (All HVAC outdoor unit installed metal
stand)
4Nos of 40A isolator switch installed
12 Nos of concrete foundation 75cm x75 cm installed for trailers
2 Nos of fabricated steps installed for doors for entry
10Nos 600mm x600mm 40W LED Panel lights installed as per approved electrical drawings
12 Nos of MK duplex socket installed with necessary GI conduit from distribution box
2 Nos of Orbik exit lights installed over the metal door
4 Nos of bulk head lights installed around the RLB
2 Nos of exhaust fan installed inside the RLB
2 Nos of MK Light switches installed
4-way main distribution panel 250A IP65 Outgoing breakers are 100A -6 Nos
Supply & Installation of 1No. FDP 100A incomer and outgoing branches 10A and 15A
Supply & installation of 250KVA Generator including oil spill containment
MSB 250A 4-way Supply & installation and incoming breaker 250A and 4 nos 100A MCCB with
indicators and stand
Supply and installation of 4CX 70 Sq.mm XLPE Cable excavated with 70cm depth
6 Nos of Furse earth pit with chamber to be installed split units HVAC MSB, FDP
Maintenance:
All light fittings, outlet sockets to check every month, if any damaged lights or sockets to be
replaced
Every 250 hours to maintain the generator for periodic maintenance
During the Generator maintenance, will change the air filter, oil filter, water filter and water
washing.
Daily inspection for Generators
2. RLB BREAKROOM AND OFFICE
RLB for Offices – Size: 15 Feet Wide X 40 Feet Long X minimum 8 Feet High
Base frame constructed by I Beam 600x200mm x11 mm size
Purling square tube 60mm x60mm x3mm (400mm Centre to Centre)
All base frames and cross beams one coat primer and two coat paint
Double layer 18mm marine plywood installed on the flooring
Over the plywood flooring 3mm thickness heavy duty PVC welded type vinyl sheet installed
Wall panel installed 100mm thick sandwich panel R20 rating
Roof panel installed 100mm thick sandwich panel with appropriated purlin R20 rating
Middle partition installed 100mm sandwich panel
From floor level 2.4m height 60mmx60mm fire rated ceiling tiles installed
1 mx 1m aluminum 4 Nos. windows installed in the RLB Office
2 Nos of metal door with Sargent lock, door closer, stopper installed in the RLB office
3 Nos of 2 Ton HVAC Mini split unit installed in the RLB office (All HVAC outdoor unit installed metal
stand)
4Nos of 40A isolator switch installed
12 Nos of concrete foundation 75cm x75 cm installed for trailers
2 Nos of fabricated steps installed for doors for entry
10Nos 600mm x600mm 40W LED Panel lights installed as per approved electrical drawings
12 Nos of MK duplex socket installed with necessary GI conduit from distribution box
2 Nos of Orbik exit lights installed over the metal door
4 Nos of bulk head lights installed around the RLB
2 Nos of exhaust fan installed inside the RLB
2 Nos of MK Light switches installed
4-way main distribution panel 250A IP65 Outgoing breakers are 100A -6 Nos
Supply & Installation of 1No. FDP 100A incomer and outgoing branches 10A and 15A
Supply & installation of 250KVA Generator including oil spill containment
Maintenance:
All light fittings, outlet sockets to check every month, if any damaged lights or sockets to be
replaced
Every 250 hours to maintain the generator for periodic maintenance
During the Generator maintenance, will change the air filter, oil filter, water filter and water
washing.
Daily inspection for Generators
3. RLB FOR MALE & FEMALE LATRINES
RLB for Latrines – Size: 15 Feet Wide X 40 Feet Long X minimum 8 Feet High
Base frame constructed by I Beam 600x200mm x11 mm size
Purling square tube 60mm x60mm x3mm (400mm Centre to Centre)
All base frames and cross beams one coat primer and two coat paint
Double layer 18mm marine plywood installed on the flooring
Over the plywood flooring 3mm thickness heavy duty PVC welded type vinyl sheet installed
Wall panel installed 100mm thick sandwich panel R20 rating
Roof panel installed 100mm thick sandwich panel with appropriated purlin R20 rating
Middle partition installed 100mm sandwich panel
From floor level 2.4m height 60mmx60mm fire rated ceiling tiles installed
1 mx 1m aluminum 4 Nos. windows installed in the RLB Office
2 Nos of metal door with Sargent lock, door closer, stopper installed in the RLB office
2 Nos of 2 Ton HVAC Mini split unit installed in the RLB office (All HVAC outdoor unit installed metal
stand)
2Nos of 40A isolator switch installed
12 Nos of concrete foundation 75cm x75 cm installed for trailers
2 Nos of fabricated steps installed for doors for entry
10Nos 600mm x600mm 40W LED Panel lights installed as per approved electrical drawings
2 Nos of MK duplex socket installed with necessary GI conduit from distribution box
2 Nos of Orbik exit lights installed over the metal door
4 Nos of bulk head lights installed around the RLB
4 Nos of exhaust fan installed inside the RLB
2 Nos of MK Light switches installed
4-way main distribution panel 250A IP65 Outgoing breakers are 100A -6 Nos
Supply & Installation of 1No. FDP 100A incomer and outgoing branches 10A and 15A
8 Nos of wash basin installed with counter top marble 25mm
8 Nos European water closets installed
4 Nos of urinal installed in male latrine
All water closets installed cubicle with aluminum fabricated doors 200mmx90mm (4 nos)
All urinal partition installed
8Nos of soap dispenser installed above the washbasin counter
4Nos of paper dispenser installed above the washbasin counter
8Nos of mirror installed above the washbasin counter
Installed water pipes, faucets, angle valves in the male & female latrine
100 Ltr boiler installed
Supply & installation of water tank 1000 Gal with necessary fittings and pressure pump system
Supply & installation of sewage tank 1000 Gal excavated and buried outside the RLB
All WC drainage lines are connected with the main sewage tank
Maintenance:
All light fittings, outlet sockets to check every month, if any damaged lights or sockets to be
replaced
Every 250 hours to maintain the generator for periodic maintenance
During the Generator maintenance, will change the air filter, oil filter, water filter and water
washing.
Daily inspection for Generators
All Faucets, angle valves, hose will be replaced time to time