Huawei Fusionsolar Smart String Ess Solution
Huawei Fusionsolar Smart String Ess Solution
Huawei Fusionsolar Smart String Ess Solution
Huawei Confidential
Continuously Creating Values for Customers
Rose to the Challenges, Sustainable Robust Growth
63.1
Enterprise 3+ million
47.6
serving more than 700 cities
39.3 BG partners with 228 of Global Fortune 500
3 Huawei Confidential
Focusing on ICT technology to provide products, solutions, and services to
three customer groups
Carriers worldwide
Consumer Enterprise
Carrier Business Cloud Business
Business Business
Information transmission
& storage
Information processing
Information distribution &
Smart PV Site Power Data Center Energy mPower Modular Power Supply
Make every PV plant Make each watt to carry Make each watt to support Make every watt drive Enable power consumption in
produce more watt more bits more hash rate more miles every industries
Green power
Efficient power consumption
generation
Key Technology
Power electronics technology ICT Digital technology
Topology encapsulating(3D)
5G
PLC CAN NB-IoT Wifi iMaster TIE Cloud Gauss DB
material(SiC, GaN) Component
5 Huawei Confidential
Continuous Innovation, Leading Solar Industry Development
String solution has been FusionSolar Smart PV 160GW
the MAINSTREAM in utility Accumulative Global Shipment
by the end of 2020
Central String
61%
59%
57%
53%
51%
50%
38%
6 Huawei Confidential
01 Company Overview 02 Trends & Challenge 03 Smart String ESS
Huawei Confidential
No Photo
TWh/yr China
60000
Carbon neutral realized in 2060
40000 EU
Wind Carbon neutral realized in 2050
30000
86% GHG emission -60% by 2030, 32% renewable energy
Solar
20000 25% Renewable
energy Strategic transformation of energy Various Power consumption companies join
Renewable
10000 energy giants accelerate Carbon Neutral RE100 & promise to achieve 100% renewable
energy power consumption
0
8
Huawei Confidential
PV LCOE Continuously Decrease
Speeding Up Innovative Technology
6.8 2020
10 1.3 1500V 450W+
String Inverter Tracker
6MW Bi-facial Mono-
Astronomical Algorithm
PV Grid Parity Times crystalline silicon
11.4
2016
26.6 7.5
SCR estimated based on renewable energy penetration rates released by Bloomberg 100%
7
Shanxi, China
80%
Inverter terminal SCR
3
0
1
2
4
5
6
7
8
9
17
10
11
12
13
14
15
16
18
19
20
21
22
23
4
2020
Grid connection standards become stricter
3 2020 2020
2025
2 2030 2025
2020
Inverter terminal SCR of
1 strong grids 2020
2025
Inverter terminal SCR 2025
of weak grids 2019.08 UK 2020.05 India 2020.06 Spain
0 Black out caused by New grid code put into NTS required terminal to
0% 5% 10% 15% 20% 25% 30% 35% 40% 45% 50% 55% 60% 65% 70%
Lighting effect support SCR=1.5
Renewable energy penetration rate
And more…
10 Huawei Confidential
Storage - Necessary Enabling Technologies
Promoting Renewable Energy from Grid Adaptation to be Gird Strengthening
PV PV + ESS + Algorithm
The electricity cost of solar/wind storage will be close to or even lower Main reasons for choosing PV + storage & wind + storage
than current mainstream peak-shifting methods
200 • Low power supply costs
LCOS [$/MWh]
150 Energy can be directly absorbed from PV or wind systems, reducing power
100 transmission and distribution costs.
50
11 Huawei Confidential
01 Company Overview 02 Trends & Challenge 03 Smart String ESS
Huawei Confidential
Smart String ESS: Delicacy Management, More Discharge Capacity
Traditional“Central”ESS Smart String ESS
13 Huawei Confidential
Smart String ESS:Optimal LCOS,Active Safety
Step-up
LUNA2000 LUNA2000 Smart Transformer Station
Station
Grid
Smart String ESS Smart PCS
Smart DC LV Panel
Smart Management System
14 Huawei Confidential
Prefabricated & Pre-installed Battery Container
1 – Door Mounted HVAC
12 distributed AC for 1C
6 distributed AC for 0.5C
2 – Battery Pack
2 16S 320Ah Battery Cell
1 4 Pack-level Optimizer
3 – Battery Rack
21 x Battery Pack per Rack
5 6 x Rack per Container
3
4 – BCU
Smart Cooling System 3 x Battery Control Unit
20ft Battery Container Distributed AC Distributed AC Distributed AC
6 x Smart Rack Controller
LPF Battery Cell
4 5 6
15 Huawei Confidential
Distributed AC Distributed AC Distributed AC
LFP Cell: Most Stable cell than Others, Less Fire Risk
Heat(J/g) Temp(℃)
Huawei Other Li-ion Battery
1200 600
1000 500
800 400
600 300
400 200
200 100
LFP LMO LCO NCM
0 0
Most Stable Stable Less Stable Less Stable LFP LMO NCM LCO
Heat Thermal Runaway
16 Huawei Confidential
Modular Smart PCS Design+ DC Panel
Smart PCS
Rated AC Capacity:200KW
Rated Input Voltage:1200Vdc
Rated Output Voltage :800Vac
Efficiency:DC-AC Max 99%
AC-DC Max 98.7%
Protection:IP66
Corrosion:C5M
Weight:<90kg
Dimensions: 875×850×365mm
Smart PCS
LUNA2000-200KTL-P0
DC Panel
Max Inputs:9
DC Panel Max Outputs:5
DCBOX-9/5-H0 Rated Breaker Current:500A
Dimensions :2000*900*1300mm
17 Huawei Confidential
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Prefabricated installation
Batteries and devices are prefabricated and pre-
installed. Reduced on-site installation cost
accounts for 2~3% of initial Capex
18 Huawei Confidential
18
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Central Solution
Min. Module SOC
19 Huawei Confidential
19
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Central Solution
20 Huawei Confidential
20
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Publicized Data
0 0
Distributed AC to replace 1
0
1
1
0
1
4 5 6 0 0
3
1 Optimal LCOS Point
1
Air Conditioner
minimize temp-rise difference in the
Environment Model
container
21 Huawei Confidential
21
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Old Rack
Old Rack Rated Capacity 70%,Usable Capacity 70%
Rated Capacity 70%,Usable Capacity 70% Smart Rack
Controller
U1 U1 U
U2 U
Smart Rack
Controller
U1
New Rack New Rack
Rated Capacity 100%,Usable Capacity 70% Rated Capacity 100%,Usable Capacity 100%
22 Huawei Confidential
22
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
LUNA2000-2064-S0 LUNA2000-2064-S0
LUNA2000-2064-S0 LUNA2000-2064-S0
LUNA2000-2064-S0 LUNA2000-2064-S0
Reserved Place
Foundation Finished
LUNA2000-2064-S0
23 Huawei Confidential
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
① O&M personnel visit ②Replace the pack onsite Auto-adjustment of new battery packs
the site No manual adjustment is required.
Pack Pack Pack
Travel expenses 0 USD
Optimizer Optimizer Optimizer
X On On On Maintenance labor
~50 USD
cost
100% 100% 100%
X X Maintenance
SOC 50% ~150 USD
SOC 50% 20~30 labor cost
minutes
24 Huawei Confidential
24
More
Lower CAPEX Optimal Design Simple O&M Safe & Reliable
Energy
Voltage/V
trigger thermal runaway & • 100% capture the fluctuation of the
charge/discharge curve.
cause fire Instantaneous fluctuation of cell • Instantly identify & cut out packs with hazard
charge/discharge curve
t/s
for maintenance safety.
Separator damage
caused by crystal
dendrite, high internal Series circuit cycle curve Derived Internal Short Circuit
temp, etc. – AI Outliers Algorithm
Voltage/V
Lithium plating caused
Voltage/V
• Accurately calculate internal resistance &
by extra-high charging
Chronic offset of cell charge and capture the slight deviation in the curve
current / low temp, etc.
discharge curve
caused by resistance change.
• Accurately locate and warn potential risks in
t/s
advance
25 Huawei Confidential
Optimal
Lower CAPEX Extended Life Simple O&M Safe & Reliable
Configuration
…
On Off Off
2 The system will not shut down when
the device fails, and
greatly reduces the impact on system
availability.
Modular PCS
Central PCS
…
26 Huawei Confidential
Network Diagram
1. Each pack has a BMU monitoring its status.
2. Each rack has a BCU communicating with BMU within
the rack and monitoring other rack level status.
3. BCU is also communicated with rack controller.
4. Each battery container has a CMU. The CMU reports
BCU information and other data in the container to the
SACU.
5. Each array has a SACU which communicates with all
PCSs, CMU/BCU, transformer monitoring device within
the array.
6. PPC gets the power set point from
EMS/AGC/AVC/SCADA or other devices, then
distributed into each SACU according to the status of
each array (power capacity, energy capacity, equipment
status, etc).
7. SACU gets the power set point from PPC, then
distributed into each PCS & Rack controller according
to the status of each PCS/Rack(power capacity, energy
capacity, equipment status, etc.).
27 Huawei Confidential
FFS Configuration & Logic
Device Num Remarks
28 Huawei Confidential
Over 10-year R&D Experience and Application in ESS Storage
ESS R&D
Team 50℃
Pole-mounted Site
Power
29 Huawei Confidential