Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

SER/CAL/CR/01

SCHWING STETTER (INDIA) PVT. LTD.


Door No: 8-2-268/1/C, Plot no-2,
Road No – 3, Arora Colony,
Banjara Hills, Hyderabad - 500034.
Phone: 9182268577
E-mail: servicesupport.hyd@schwingstetterindia.com

Ref: SSI/H/2021/AEL Date: 08.11.2021

M/s. APARNA Enterprises Limited


SY.NO.460/2,461,462/2 & 479 to 482,
Plot # 17&17A, APIIC Industrial Est
IDA Mankhal,Maheshwaram Mandal,
Telangana.

Kind Attn.: Mr. Subba Reddy

Dear Sir,

As per the government of India Rules it is an obligation for the Owners of all Batching
Plants to get an authorized certificate from Weights & Measurement Department in the
respective area. So it is requested to get the certification done by inviting the Local
weights and measures’ concerned Inspector for stamping and get the certificate for
operating the machines.

Required Application Form is enclosed. This application can be typed on your


letter head and send to Govt. for stamping the Batching Plant.

For Further queries, be feel free to call us.

Assuring you the best of services all the times

Encl: - As mentioned above.

Regd., Corporate Office & Works :


F-71, Sipcot Industrial Park, Irungattukottai, Sriperumbudur Taluk, Kancheepuram District, Tamil Nadu – 602105.
Phone +91 - 44 – 37178100 / 47108100 / 27156780 / 27156781 Fax : +91 - 44 – 27156539 / 47100032 / 47100053 E-mail : info@schwingstetterindia.com
Branches - Ahmedabad, Bangalore, Chandigarh, Cochin, Hyderabad, Jamshedpur, Kolkata, Mumbai and Delhi

Page 1 of 6
SCHWING STETTER (INDIA) PVT. LTD.
Door No: 8-2-268/1/C, Plot no-2,
Road No – 3, Arora Colony,
Banjara Hills, Hyderabad - 500034.
Phone: 9182268577
E-mail: servicesupport.hyd@schwingstetterindia.com

CALIBRATION CERTIFICATE

We here by certify that the M1 Batching Plant bearing M/c Sr.No: 224 supplied by
us to M/s. APARNA ENTERPRISES LIMITED was calibrated* on 05-11-2021 by our Service
Engineer Mr. Jinu in presence of Mr. Subba Reddy and the calibration details are
enclosed herewith. We certify that all the parameters are well within the tolerance limit.

Place: Hyderabad
Date: 08-11-2021.

Encl: Calibration Details (Total: 07 Pages)


Regd., Corporate Office & Works :
F-71, Sipcot Industrial Park, Irungattukottai, Sriperumbudur Taluk, Kancheepuram District, Tamil Nadu – 602105.
Phone +91 - 44 – 37178100 / 47108100 / 27156780 / 27156781 Fax : +91 - 44 – 27156539 / 47100032 / 47100053 E-mail : info@schwingstetterindia.com
Branches - Ahmedabad, Bangalore, Chandigarh, Cochin, Hyderabad, Jamshedpur, Kolkata, Mumbai and Delhi

Page 2 of 6
*Calibrated by the Calibrated weights arranged by customer
SER/CAL/WR/01

Calibration Report for Aggregate Weigher

Ascending Order Descending Order

Actual Meter Actual Meter


Error Error
Weight Reading Weight Reading
0 0 0 2000 1999 -1
100 100 0 1900 1899 -1
200 199 -1 1800 1799 -1
300 300 0 1700 1698 -2
400 400 0 1600 1599 -1
500 499 -1 1500 1498 -2
600 599 -1 1400 1398 -2
700 699 -1 1300 1298 -2
800 799 -1 1200 1198 -2
900 899 -1 1100 1099 -1
1000 999 -1 1000 998 -2
1100 1099 -1 900 898 -2
1200 1199 -1 800 798 -2
1300 1299 -1 700 699 -1
1400 1399 -1 600 599 -1
1500 1500 0 500 499 -1
1600 1598 -2 400 399 -1
1700 1699 -1 300 299 -1
1800 1799 -1 200 199 -1
1900 1899 -1 100 99 -1
2000 1999 -1 0 0 0

Page 3 of 6
SER/CAL/WR/01

Calibration Report for Cement Weigher

Ascending Order Descending Order


Actual Meter Actual Meter
Weight Reading Error Weight Reading Error
0 0 0 600 601 1
20 20 0 580 581 1
40 40 0 560 561 1
60 60 0 540 541 1
80 80 0 520 521 1
100 100 0 500 500 0
120 120 0 480 480 0
140 140 0 460 460 0
160 160 0 440 440 0
180 180 0 420 420 0
200 200 0 400 400 0
220 220 0 380 380 0
240 240 0 360 360 0
260 260 0 340 340 0
280 280 0 320 320 0
300 300 0 300 300 0
320 320 0 280 280 0
340 340 0 260 260 0
360 360 0 240 240 0
380 380 0 220 220 0
400 400 0 200 200 0
420 419 -1 180 180 0
440 440 0 160 160 0
460 460 0 140 140 0
480 480 0 120 120 0
500 500 0 100 100 0
520 521 1 80 80 0
540 541 1 60 60 0
560 561 1 40 40 0
580 581 1 20 20 0
600 601 1 0 0 0

Page 4 of 6
Calibration Report for Water Weigher

Ascending Order Descending Order

Actual Meter Actual Meter


Error Error
Weight Reading Weight Reading
0 0 0 300 300 0
20 20 0 280 280 0
40 40 0 260 260 0
60 60 0 240 240 0
80 80 0 220 220 0
100 100 0 200 200 0
120 120 0 180 180 0
140 140 0 160 160 0
160 160 0 140 140 0
180 180 0 120 120 0
200 200 0 100 100 0
220 220 0 80 80 0
240 240 0 60 60 0
260 260 0 40 40 0
280 280 0 20 20 0
300 300 0 0 0 0

SER/CAL/WR/01

Calibration Report for Admixture Weigher

Ascending Order Descending Order

Actual Meter Actual Meter


Error Error
Weight Reading Weight Reading
0 0 0 10000 10000 0
1000 1001 1 9000 9001 1
2000 2001 1 8000 8000 0
3000 3000 0 7000 7000 0
4000 4002 2 6000 6000 0
5000 5000 0 5000 5000 0
6000 6000 0 4000 4001 1
7000 7000 0 3000 3001 1
8000 8000 0 2000 2000 0
9000 9000 0 1000 1000 0
10000 10000 0 0 0 0

Page 5 of 6
Plant Details

Customer name : M/s. APARNA ENTERPRISES LIMITED

Address : IDA Mankhal,Maheshwaram Mandal,

Batching Plant Model : M1

Batching Plant Sl.No : 224

Max. Weight Used For Calibration Of


Aggregate Weigher : 2000 kg

Max. Weight used For Calibration of


Cement Weigher : 600 kg

Max. Weight used For Calibration of


Water Weigher : 300 kg

Max. Weight used For Calibration of


Admixture Weigher : 6000 Grams

Calibration date : 05-11-2021

Next Due Date for calibration* : 04-02-2022

 Provided that the plant is well maintained as per maintenance schedule and
cleaned on a daily basis,

 As per IS 4926 once in every three months the weigher shall be calibrated for the
full working Range

Page 6 of 6