(CS-2020-047 - EN) Work Procedure For DX22 GEN ECU Replacement

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Ref No.

: CS-2020-047_EN

Service Bulletin
Application: GEN-SET
Date: Sep 14, 2020
Editor: Dongwuk Lee

Subject Work Procedure for DX22 ECU Replacement


Model DX22 GEN
Applied Date Aug. 2020 Region ALL

1. Background 2) Loosen Hex bolt x 6ea

This Service Bulletin provides information for


replacement procedure of DX22 GEN ECU

2. Work Procedure
A. Preparation
1) Tool
- Wrench ratchet with 10mm socket or 10mm spanner

3) Disconnect ECU connector x 8ea


- Disconnect connector from 1st to 8th

- ECU (New one)


- Press Hold key and Pull down Lever one by one

4) Remove Harness holder x 4ea


- Lift up Harness holder from ECU Bracket. Holder will
B. Work Procedure
be separated easily from ECU Brackets
1) Key OFF and wait over 30 seconds so that Main ECU
power relay turns off. Engine Power off

Warranty Part / CS Engineering Team / Sales&PS / Engine Business Group


Doosan Infracore Co., Ltd Page 1 / 2
- Pull down Lever tightly at bottom line then Lift up
Lever until hear “tick” locking sound

5) Replace old ECU to New ECU


8) Fix Harness holder x 4ea

- Press down Harness holder to ECU Bracket. Check


Harness holder is fixed on ECU Bracket

6) Assemble Hex bolt x 6ea

9) Engine Power on and and Key on. Check system.

7) Connect ECU connector x 8ea E.O.D


Warranty Part / CS Engineering Team / Sales&PS / Engine Business Group
Doosan Infracore Co., Ltd Page 2 / 2

You might also like