Water Quality Analysis

3. Name the new alternative Chlorine Injection and double-click to open.

4. Click the Ellipsis (…) next to the Constituent drop-down menu to open the
Constituents manager.
5. Make sure that the Chlorine Label is highlighted, and enter the data below in that
dialog box.

Label Chlorine

Diffusivity 1.2e-9 m2/s

First Order Wall


-0.08 m/day
Reaction Rate

Bulk Reaction Rate -0.10 (mg/L)^(1-n)/day

6. Leave the Unlimited Concentration check box selected, and click OK.

7. Click Close to exit the Constituent Library. You should now be back in the
Constituent Alternative Editor.
8. Select Chlorine from the Constituent list box.