3 3
window ledge window ledge window ledge window ledge

ELECTRICAL SYMBOLS
20WATTS COMPACT FLUORESCENT LAMP
WITH MEDIUM BASE, KEYLESS TYPE
PORCELAIN RECEPTACLE OUTLET

window ledge
2 2 DUPLEX CONVENIENCE OUTLET,
GROUNDING TYPE,10A, 250VOLTS "WP"
DENOTES WEATHERPROOF OUTLET
CIRCUIT HOMERUN

window ledge
DISTRIBUTION PANELBOARD

window ledge
M ELECTRICAL SERVICE METER

window ledge
window ledge

CO ELECTRICAL SERVICE ENTRANCE

1 window ledge window ledge


01

1 window ledge
CO
02 2-POLE CIRCUIT BREAKER,
PLUG-IN TYPE

1 GR. FL. LIGHTING LAYOUT 2 2ND FL. LIGHTING LAYOUT


E1 SCALE = 1:100 m E1 SCALE = 1:100 m
GENERAL NOTES
A B C
1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISION

A B C
OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, EXISTING
APPLICABLE ORDINANCES, RULES AND REGULATIONS OF THE LOCAL
GOVERNMENT AND WITH THE REQUIREMENTS OF THE LOCAL POWER COMPANY.
2. THE TYPE OF SERVICE POWER SUPPLY TO BE USED SHALL BE SINGLE-PHASE,
2-WIRE, 230V, 60 HERTZ, A.C.

3 3
window ledge window ledge window ledge window ledge

3. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF


SERVICE ENTRANCE FOR CONNECTION TO THE POWER COMPANY SERVICE POINT.
4. UNLESS OTHERWISE SPECIFIED, THE MINIMUM SIZES OF WIRE AND GALVANIZED
RIGID STEEL CONDUIT TO BE USED SHALL BE 3.5mm2, THHN AND 15mm NOMINAL
DIAMETER, RESPECTIVELY. LIKEWISE ALL ELECTRICAL WIRES SHALL BE
COLOR-CODED.
5. ALL LIGHTING CIRCUIT HOMERUNS AND CONVENIENCE OUTLETS SHALL BE WIRED
WITH NOT LESS THAN 3.5mm2 IN SIZE.
6. WHEREVER REQUIRED AND NECESSARY, PULL OR JUNCTION BOXES SHALL BE
window ledge

INSTALLED AT CONVENIENT AND INCONSPICUOUS LOCATION, ALTHOUGH SUCH

2 2 7.
BOXES ARE NOT SHOWN ON THE PLAN NOR MENTIONED IN THE SPECIFICATIONS.
ALL NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL
BE PROPERLY GROUNDED IN ACCORDANCE WITH THE PROVISIONS IN ARTICLE 2.50
"GROUNDING" PHILIPPINE ELECTRICAL CODE, VOLUME 1, 2000 EDITION.
8. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE APPROVED TYPE
FOR LOCATION AND PURPOSE.

window ledge
9. STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES, TERMINATIONS AND OTHER
window ledge

APPURTENANCES FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE USED.


10. ALL WALL OUTLETS SHALL BE INSTALLED AT THE FOLLOWING HEIGHTS ABOVE
window ledge

THE FINISHED FLOOR LEVEL UNLESS NOTED IN THE PLANS.


window ledge

A) WALL SWITCHES @ 1200mm

1 1
CO CO B) WALL CONVENIENCE OUTLETS @ 300mm OR 150mm ABOVE WORKTABLE/COUNTER
window ledge
03 window ledge
window ledge
04 C) WALL FAN OUTLET @ CONVENIENCE HEIGHT
11. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER.

3 GR. FL. POWER LAYOUT 4 2ND FL. POWER LAYOUT


E1 SCALE = 1:100 m E1 SCALE = 1:100 m

ENGINEER PROJECT TITLE/ LOCATION OWNER PROJECT NUMBER

PROPOSED CONSTRUCTION OF A TWO- BLDG. 3


PRC NO: PTR NO: STOREY RESIDENTIAL BUILDING DATE SHEET NO. PAGE NO.
ISSUED ON: ISSUED ON: BRGY. LENIENZA, PAGADIAN CITY, ZAMBOANGA DEL SUR
ISSUED AT: ISSUED AT:
December 30, 2021 E1 21