Cargo Hatch Cover(s) Test Report

Vessel’s name: Karya Mandiri IMO/ Distintive No.: 85195338

Hatch cover type: Sliding type Manufacturer: -

Total no. of hatches: 1 Hatch Cover(s) tested: Ultrasonic Test

Date of test: 31/3/2022 Place of test: pangkalan Bun

Test method: Ultrasonic Test Time commenced / completed: 1350 / 1450

Ultrasonic Transmitter: Cygnus Date last calibrated: 16/1/2022


equipment
type: Receiver: Ultra sonic Hatch Leak Detectior Date last calibrated: 16/1/2023

Measurements with opened hatch (Minimum preferred Opened Hatch Value (OHV) is 40dB)

Hatch No. OHV Measured (dB)


(from forward) (To be uniform over the tested area) 10% of OHV (dB) Remarks
1 76 0 Fwd hatch 1
…….. …….. 0 Fwd hatch 2
…….. …….. 3 Fwd hatch 3
…….. …….. 0 Fwd hatch 4
…….. …….. 0 Fwd hatch 5
…….. …….. 1 Aft hatch 1
…….. …….. 0 Aft hatch 2
…….. …….. 2 Aft hatch 3
…….. …….. 0 Aft hatch 4
…….. …….. 0 Aft hatch 5

Fail / Pass Criterion1 -


 Measured reading = 76 dB – Hatch cover is leaktight
 3 dB <measured reading< 10% of OHV – Hatch cover considered weathertight, subject to visual inspection and consideration
of hatch design
 Measured reading ≧10 % of OHV – Hatch cover is not considered weathertight, appropriate corrective action(s) are to
be taken/ effected

Note: Where the preferred ultrasonic test is not possible to conduct at time of attendance, the attending surveyor should conduct
appropriate alternate assessment test where practicable as far as reasonable.

Alternate evaluation test method conducted: ☐ Hose test ☐ Light test ☐ Chalk test

1 With accordance to the general criteria adopted by IACS

Cargo Hatch Cover(s) Test Report_Version 1.0 Page 1 of 3


Test Result/ Measurements with closed hatch where measured readings Re-test result/ Re-measurements after
≧10% OHV corrective actions (if applicable) Hatch Cover Diagram
Measured Measured (Surveyor to indicate roughly positions the areas where leakage (≧10% OHV)
based on the Hatch Cover Diagram enclosed)
Position reading reading
Hatch (dB)
Visual/ Test (dB)
(to be indicated in the Hatch
Cover Diagram) cover # (where applicable) inspection findings Corrective action(s) taken (where applicable) Remarks
Fwd 1 76 0 Fwd, Port & Starboard side …….. Avarage Reading
hatch 1
…….. …….. …….. 0 Fwd, Port & Starboard side …….. Avarage Reading
hatch 2
…….. …….. …….. 3 Fwd, Port & Starboard side …….. Avarage Reading
hatch 3
…….. …….. …….. 0 Fwd, Port & Starboard side …….. Avarage Reading
hatch 4
…….. …….. …….. 0 Aft, Port & Starboard side …….. Avarage Reading
hatch 5
…….. …….. …….. 1 Aft, Port & Starboard side …….. Avarage Reading
hatch 1
…….. …….. …….. 0 Aft, Port & Starboard side …….. Avarage Reading
hatch 2
…….. …….. …….. 2 Aft, Port & Starboard side …….. Avarage Reading
hatch 3
…….. …….. …….. 0 Aft, Port & Starboard side …….. Avarage Reading
hatch 4
…….. …….. …….. 0 Aft, Port & Starboard side …….. Avarage Reading
hatch 5
…….. …….. …….. Click here to enter text. Click here to enter text. …….. Click here to enter text.
…….. …….. …….. Click here to enter text. Click here to enter text. …….. Click here to enter text.
…….. …….. …….. Click here to enter text. Click here to enter text. …….. Click here to enter text.
…….. …….. …….. Click here to enter text. Click here to enter text. …….. Click here to enter text.

Note: Testing and objective defects observation photos are to be attached together with this test report.

Cargo Hatch Cover(s) Test Report_Version 1.0 Page 2 of 3


(Where applicable)

(signature and official stamp) (signature and official stamp) (signature and official stamp)
Name of (lead) surveyor: Muchlis Rumalutur Name of ultrasonic operator: Click here to enter text. Name of Master: Kasino
Name of organisation: PT. Areva Maritim Perdana Name of service provider: Click here to enter text.

Cargo Hatch Cover(s) Test Report_Version 1.0 Page 3 of 3