Features: Switching Regulator
Features: Switching Regulator
Selection Guide
Part Input Output Output Efficiency
Number Voltage Range Voltage Current @ min Vin @ max. Vin
[VDC] [VDC] [A] [%] [%]
R-781.8-1.0 4.75 - 18 1.8 1.0 82 76
R-782.5-1.0 4.75 - 18 2.5 1.0 87 81
R-783.3-1.0 4.75 - 18 3.3 1.0 90 84
R-785.0-1.0 6.5 - 18 5.0 1.0 94 89
Model Numbering
R-78__-1.0
Output Voltage Output Current
IEC/EN60950-1 certified
EN55032 compliant
Specifications (measured @ Ta= 25°C, 10% minimum load, unless otherwise stated)
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Quiescent Current Vin = min. to max. at 0% load 5mA 7mA
Internal Power Dissipation 0.4W
Minimum Load (1) 0%
Internal Operating Frequency 280kHz 350kHz 430kHz
Notes:
Note1: Operation under no load will not harm the converter, but specifications may not be met
A minimum load of 10mA is recommended
Ripple [mV]
60 30
50 25
40 20
30 5Vout 15
20 3.3Vout 10
2.5Vout
10 1.8Vout 5
0 0
5 7 9 11 13 15 17 18 5 7 9 11 13 15 17 18
Input Voltage [VDC] Input Voltage [VDC]
Efficiency vs. Load (max. Vin) Ripple vs. Load (max. Vin)
100 50 5Vout
3.3Vout
90 45
2.5Vout
80 40 1.8Vout
70 35
Efficiency [%]
Ripple [mV]
60 30
50 25
40 20
30 5Vout 15
20 3.3Vout 10
2.5Vout
10 1.8Vout 5
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
Efficiency vs. Load (min. Vin) Ripple vs. Load (min. Vin)
100 50 5Vout
3.3Vout
90 45
2.5Vout
80 40 1.8Vout
70 35
Ripple [mV]
Efficiency [%]
60 30
50 25
40 20
30 5Vout 15
20 3.3Vout 10
2.5Vout
10 1.8Vout 5
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Short Circuit Input Current nom. Vin= 12VDC R-78xx-1.0 100mA max.
+Vin +Vin +Vout +Vout
Optional Diode Protection Circuit GND
Derating Graph
100
80
Output Power [%]
60
40
30
20
0
-40 0 20 40 60 80 100
85
Ambient Temperature [°C]
www.recom-power.com REV.: 4/2019 I-3
R-78xx-1.0
DC/DC Converter Series
Specifications (measured @ Ta= 25°C, 10% minimum load, unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
IEC60950-1:2005, 2nd Edition + AM 2:2013
Information Technology Equipment, General Requirements for Safety 1603123
EN60950-1:2006 + AM 2:2013
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS 2011/65/EU + AM2015/863
L1 R-78xx-1.0
+Vin +Vin +Vout +Vout
GND
C1 C2
GND GND
Notes:
Note2: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
embossed logo
11.5 7.55
10.2
Pin # Single
0.51
1 +Vin
2 GND
3 +Vout
4.10
5.08 3.21
Recommended Footprint Details
Top View
1 2 3 1 2 3
2.00
2.54
Bottom View
2.54
GND GND
GND C1, C2: optional GND
C1, C2: optional
- High isolation voltage
-- High isolation
Improved loadvoltage
/ line Regulation
-- Wide
Improved
inputload / line Regulation
voltage
-- Wide input voltage
Point-of-load architecture
- Point-of-load architecture
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.