Cooling Tower Catalogue

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 21

SUPER TOWER INDUSTRIES

COOLING TOWER
MANUFACTURER

BND Series ADVANTAGES


BHD Series · Space Saver

FBND Series · Energy Saver


· Low Maintenance Cost
FBNZ Series
· Low Noise
FBNG Series · Low Drift Loss
FRP Tank · Compact Unit
· Quake Proof Design
COMPANY
COMPANY PROFILE
PROFILE

SUPER TOWER INDUSTRIES


COOLING TOWER MANUFACTURER

SUPER TOWER INDUSTRIES is established as a professional company manufacturing


cooling towers in Singapore and China, and has been actively involved in supplying,
installing and maintaining top quality cooling towers all over Singapore.

SUPER TOWER INDUSTRIES is certified and registered as a Cooling Tower Institute


(CTI) Member in U.S.A. We hold a unique position in the industry, for not only do we
supply, install and maintain Cooling Towers, our factory in Singapore and China also
manufactures all kinds of Cooling Towers such as : FRP Bottle type, Counter flow round
type, Cross flow square type, special custom made type and other spare parts for all kind
of Cooling Tower, example: crossflow square tower with side discharge.

Our Cooling Tower are featured with energy saving, compact and light weight, reduced
noise pollution, corrosion resistant, fireproof and quakeproof. We provide easy access to
all kinds of Cooling Tower spare parts such as Sprinkler heads, Sprinkler pipes, Suction
Strainers, PVC infill, aluminium infilled, Drift eliminators, etc.
New regulations were imposed by ENV in Singapore to control Legionnaires Disease on
all Cooling Towers under Chapter 95 act. We (SUPER TOWER INDUSTRIES) are
pleased to introduce and highlight that we have innovative design for supplying all
makes and models of round and square Cooling Tower's Drift Eliminator based on the
latest ENV Regulation.

SUPER TOWER INDUSTRIES management spirit is firmly grounded in the belief that
we must offer only the highest quality services to our clients and engage in business
relationship which are not only beneficial to ourselves, but to our clients as well. This
principal has been the guiding influence on all SUPER TOWER INDUSTRIES business
strategies and goals.
Low Noise & Super Low Noise Cross-Flow Cooling Tower

Features
For centrifugal refrigerating machine and other cooling applications:

BHD series - Low noise type


- Super-low noise / Energy-saving type

The advantages of the BHD series are:

1 Energy Saving
The fan power consumption is
greatly reduced by the lower
pressure loss filler together
4 Anti-corrosiveness
All the main components are
made of the anti-corrosive
materials such as FRP and HDG steel.
with the bell-mounted fan stack.

2
Space-saving, light weight and No requirement of any special
package unit
Operating weight, installation
space and time are lower than
5 foundation
All the units supply with the
standard footings so the very
the conventional types since our simple foundation is required.
higher-heat-exchanger-rate filler.

Low noise level Fireproof material

3 Both the series satisfy the standard


noise level specified by CTI & JCI. 6 All the units are constructed with
FRP - the fireproof material.

7 Quakeproof design
Our standard design is based on
1.0th degree and 0.5th degree
vertical. Any other specification
and design are available. ①



Structure ④

1. Motor 11. Ladder ⑥
2. Fan 12. Make Up Water Pipe ⑦
3. Fan Casing 13. Water Basin ⑧

4. Distributor

5. Upper Water Basin ⑪
6. Internal Pipe
7. PVC Infill ⑫
8. Internal Frame Support ⑬
9. Casing Plate
10. Inspection Door
Super Low Noise Cross-Flow Square Cooling Tower

BHD
series
Standard Specifications – Part I
Model Dimensions (mm) Motor Fan Dia. Piping Diameter mm DN x no Weight (kkg)
No.
415/50HZ Drain Manual
BHD-t L W H Ømm x no Inlet x no Outlet x no Dry Wet
Kw x no Overflow Auto

1 BHD-50t 1200 2170 3100 1.1 x 1 900 x 1 80 x 1 80 x 1 40/40 x 1 20/20 x 1 0.43 1.15
2 BHD-75t 1500 2470 3100 1.1 x 1 1100 x 1 100 x 1 100 x 1 40/40 x 1 20/20 x 1 0.58 1.5
3 BHD-85t 1500 2470 3150 1.5 x 1 1200 x 1 100 x 1 100 x 1 40/40 x 1 25/25 x 1 0.65 1.55
4 BHD-100t 1500 2470 3150 2.2 x 1 1300 x 1 100 x 1 100 x 1 40/40 x 1 25/25 x 1 0.75 1.7
5 BHD-125t 1800 2770 3250 2.2 x 1 1500 x 1 125 x 1 125 x 1 40/40 x 1 25/25 x 1 0.96 1.94
6 BHD-150t 1800 2770 3730 3.0 x 1 1500 x 1 150 x 1 150 x 1 40/40 x 1 32/32 x 1 1.03 2.02
7 BHD-175t 1900 2810 3850 4.0 x 1 1600 x 1 150 x 1 150 x 1 40/40 x 1 32/32 x 1 1.2 2.37
8 BHD-200t 2310 3210 3950 4.0 x 1 1800 x 1 150 x 1 150 x 1 40/40 x 1 32/32 x 1 1.4 2.52
9 BHD-225t 2310 3210 3950 4.0 x 1 1900 x 1 150 x 1 150 x 1 40/40 x 1 32/32 x 1 1.52 2.64
10 BHD-250t 2590 3520 3950 5.5 x 1 2000 x 1 200 x 1 200 x 1 50/50 x 1 32/32 x 1 1.67 4.9
11 BHD-275t 2590 3520 3950 5.5 x 1 2100 x 1 200 x 1 200 x 1 50/50 x 1 32/32 x 1 1.79 5.02
12 BHD-300t 3600 2770 3830 3.0 x 2 1500 x 2 150 x 2 150 x 2 40/40 x 2 32/32 x 2 1.96 3.96
13 BHD-350t 3800 2810 3850 4.0 x 2 1600 x 2 150 x 2 150 x 2 40/40 x 2 32/32 x 2 2.4 4.74
14 BHD-400t 4620 3210 3950 4.0 x 2 1800 x 2 150 x 2 150 x 2 40/40 x 2 32/32 x 2 2.8 5.04
15 BHD-450t 4620 3210 3950 4.0 x 2 1900 x 2 150 x 2 150 x 2 50/50 x 2 32/32 x 2 3.04 5.28
16 BHD-500t 5180 3520 3950 5.5 x 2 2000 x 2 200 x 2 200 x 2 40/40 x 2 32/32 x 2 3.34 6.8
17 BHD-600t 6930 3210 3950 4.0 x 3 1800 x 3 150 x 3 150 x 3 40/40 x 3 32/32 x 3 4.2 7.56
18 BHD-800t 9240 3210 3950 4.0 x 4 1800 x 4 150 x 4 150 x 4 40/40 x 4 32/32 x 4 5.6 10.08
19 BHD-900t 9240 3210 3950 4.0 x 4 1900 x 4 150 x 4 150 x 4 40/40 x 4 32/32 x 4 6.08 10.56
20 BHD-1000t 10360 3520 4200 5.5 x 4 2000 x 4 200 x 4 200 x 4 50/50 x 4 32/32 x 4 6.68 19.6
21 BHD-1200t 12950 3520 4200 5.5 x 5 2000 x 5 200 x 5 200 x 5 50/50 x 5 32/32 x 5 8.35 24
22 BHD-1500t 15540 3520 4200 5.5 x 6 2000 x 6 200 x 6 200 x 6 50/50 x 6 32/32 x 6 10.02 29.4
23 BHD-2000t 20720 3520 4200 5.5 x 8 2000 x 8 200 x 8 200 x 8 50/50 x 8 32/32 x 8 13.36 39.2
24 BHD-2500t 25900 3520 4200 5.5 x 10 2000 x 10 200 x 10 200 x 10 50/50 x 10 32/32 x 10 16.7 49
25 BHD-3000t 31080 3520 4900 5.5 x 12 2000 x 12 200 x 12 200 x 12 50/50 x 12 32/32 x 12 20.04 58.8
26 BHD-3500t 36260 3520 4900 5.5 x 14 2000 x 14 200 x 14 200 x 14 50/50 x 14 32/32 x 14 23.38 68.6
27 BHD-4000t 41440 3520 4900 5.5 x 16 2000 x 16 200 x 16 200 x 16 50/50 x 16 32/32 x 16 26.72 78.4
28 BHD-5000t 51800 3520 4900 5.5 x 20 2000 x 20 200 x 20 200 x 20 50/50 x 20 32/32 x 20 33.4 98
29 BHD-6000t 62160 3520 4900 5.5 x 24 2000 x 24 200 x 24 200 x 24 50/50 x 24 32/32 x 24 40.08 117.6
30 BHD-7000t 72520 3520 4900 5.5 x 28 2000 x 28 200 x 28 200 x 28 50/50 x 28 32/32 x 28 46.76 137.2
31 BHD-8000t 82880 3520 4900 5.5 x 32 2000 x 32 200 x 32 200 x 32 50/50 x 32 32/32 x 32 53.44 156.8
32 BHD-9000t 93240 3520 4900 5.5 x 36 2000 x 36 200 x 36 200 x 36 50/50 x 36 32/32 x 36 60.12 176.4
33 BHD-10000t 103600 3520 4900 5.5 x 40 2000 x 40 200 x 40 200 x 40 50/50 x 40 32/32 x 40 66.8 196
34 BHD-20000t 207200 3520 4900 5.5 x 80 2000 x 80 200 x 80 200 x 80 50/50 x 80 32/32 x 80 133.6 392
35 BHD-30000t 310800 3520 4900 5.5 x 120 2000 x 120 200 x 120 200 x 120 50/50 x 12032/32 x 120 200.4 588
Super Low Noise Cross-Flow Square Cooling Tower

BHD
series
Standard Specifications – Part II - Selection Chart -
Wet Bulb (27°C) Flow Rate (L/min) Wet Bulb (28°C) Flow Rate (L/min)
Dimensions (mm)
Model

Inlet Temp 37 38 40 42 45 35 40 35 43 45 37 38 43 45 35 35

Outlet Temp 32 32 32 32 32 30 30 29.5 33 35 32 32 33 35 29.5 30 L W H

BHD-50t 650 580 452 395 310 420 280 340 452 590 565 485 420 575 255 330 1200 2170 270

BHD-75t 975 875 680 595 465 635 425 510 680 680 850 730 635 865 382 493 1500 2470 2700

BHD-85t 1105 990 768 670 530 720 480 575 768 1008 960 825 720 980 430 555 1500 2470 2750

BHD-100t 1300 1165 905 790 620 848 565 678 905 1185 1130 970 848 1150 510 655 1500 2470 2750

BHD-125t 1625 1450 1130 980 775 1060 705 845 1130 1480 1410 1210 1060 1438 635 818 1800 2770 2850

BHD-150t 1950 1745 1356 1185 930 1270 845 1020 1356 1780 1695 1460 1270 1725 760 980 1800 2810 3330

BHD-175t 2275 2040 1585 1385 1090 1485 990 1188 1585 2080 1980 1700 1485 2020 890 1150 1900 2810 2450

BHD-200t 2600 2330 1810 1580 1240 1695 1130 1355 1810 2370 2260 1940 1695 2305 1020 1310 2310 3210 3550

BHD-225t 2925 2620 2040 1780 1400 1910 1270 1530 2040 2675 2545 2189 1910 2595 1145 1475 2310 3210 3550

BHD-250t 3250 2915 2265 1980 1555 2120 1415 1700 2265 2970 2830 2430 2120 2885 1270 1640 2590 3520 3550

BHD-275t 3575 3200 2490 2180 1710 2330 1555 1865 2490 3265 3110 2675 2330 3170 1400 1800 2590 3520 3550

BHD-300t 3900 3490 2710 2375 1865 2540 1695 2030 2710 3560 3390 2915 2540 3455 1525 1966 3600 2810 3330

BHD-350t 4550 4080 3170 2770 2180 2970 1980 2375 3170 4155 3960 3405 2970 4040 1780 2295 3800 2810 3450

BHD-400t 5200 4655 3615 3165 2485 3390 2260 2710 3615 4745 4520 3890 3390 4610 2035 2621 4620 3210 3550

BHD-450t 5850 5240 4070 3560 2800 3820 2545 3055 4070 5345 5090 4380 3820 5190 2290 2950 4620 3210 3550

BHD-500t 6500 5820 4520 3955 3105 4235 2825 3390 4520 5930 5650 4860 4240 5760 2540 3275 5180 3520 3550

BHD-600t 7800 6985 5425 4746 3729 5085 3390 4068 5425 7120 6780 5830 5085 6915 3050 3930 6930 3210 3550

BHD-800t 10400 9320 7240 6335 4980 6785 4525 5430 7240 9500 9050 7785 6785 9230 4075 5250 9240 3210 4210

BHD-900t 11700 10485 8145 7125 5600 7635 5090 6110 8145 10690 10180 8755 7635 10385 4580 5905 9240 3210 4210

BHD-1000t 13000 11650 9048 7915 6220 8480 5655 6785 9045 11875 11310 9725 8480 11535 5090 6560 10360 3520 4210

BHD-1200t 15600 13975 10855 9500 7465 10175 6785 8140 10855 14245 13570 11670 10175 13840 6105 7870 12950 3520 4210

BHD-1500t 19500 17460 13560 11865 9320 12710 8475 10170 13560 17800 16950 14575 12710 17290 7625 9830 15540 3520 4210

BHD-2000t 26000 23300 18095 15830 12440 16965 11310 13570 18095 23750 22620 19450 16965 23070 10180 13120 20720 3520 4210

BHD-2500t 32500 29120 22615 19790 15550 21200 14135 16960 22615 29680 28270 24310 21200 28835 12720 16395 25900 3520 4210

BHD-3000t 39000 34950 27145 23750 18660 25445 16965 20355 27145 35625 33930 29180 25445 34605 15270 19680 31080 3520 4820

BHD-3500t 45500 40765 31665 27705 21770 29685 19790 23750 31665 41560 39580 34040 29685 40370 17810 22955 36260 3520 4820

BHD-4000t 52000 46580 36190 31670 24880 33930 22620 27145 36190 47500 45240 38906 33930 46145 20358 26240 41440 3520 4820

BHD-5000t 65000 58245 45240 39585 31100 42410 28275 33930 45240 59375 56550 48630 42410 57680 25445 32780 51800 3520 4820

BHD-6000t 78000 69895 54290 47500 37320 50895 33930 40715 54290 71250 67860 58360 50895 69215 30535 39360 62160 3520 4820

BHD-7000t 91000 81545 63340 55420 43540 59380 39585 47500 63335 83130 79170 68090 59380 80750 35630 45920 72520 3520 4820
Standard Low Noise Cross-Flow Square Cooling Tower

BHD
series
Foundation Drawing

W + 300

L - 100

BHD50-275t
Standard Low Noise Cross-Flow Square Cooling Tower

BHD
series
Foundation Drawing

W + 300

BHD300-500t
Standard Low Noise Cross-Flow Square Cooling Tower

BHD
series
Foundation Drawing

W + 300

BHD-600t
Standard Low Noise Cross-Flow Square Cooling Tower

BHD
series
Foundation Drawing

W + 300

BHD800-1000t
Standard Low Noise Cross-Flow Square Cooling Tower

BHD
series
Foundation Drawing

W + 300

BHD-1200t On Wards
Single Cell Counter-Flow Square Cooling Tower

FBND, FBNZ, FBNG


series

Standard Specifications
Fan Noise
Dimensions Motor Piping Diameter Weight
Diameter Level
MODEL
M³/hr. a b c Drain e Manual Dry Wet
L W H DB
KW Inlet Outlet d Overflow f Auto Makeup Weight Weight
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (A)
(kg) (kg)
FBND Single Cell - Low Noise Type
300 4000 4000 5500 5.5 2400 200 250 25/50 50/25 3500 5000 65
375 4000 4000 5500 7.5 2800 200 250 25/50 50/25 3600 5100 66
450 4900 4900 6000 7.5 3400 250 300 25/50 50/25 4350 5850 67
600 5500 5500 6500 11 4200 250 300 50/80 65/40 6500 8000 68
750 6300 6300 7000 18.5 4600 300 350 50/80 65/40 6500 8000 69
900 6300 6300 7500 22 5000 300 350 50/80 65/40 7500 10500 70
1050 7200 7200 7500 30 5000 300 350 50/80 65/40 8500 11500 71
1300 7200 7200 8000 37 5000 300 350 50/80 65/40 9900 18000 72
1500 9400 9400 8500 45 6000 400 450 50/80 65/40 10900 19400 73
1800 10000 10000 9000 55 6000 500 550 50/100 80/50 14500 24000 74
2250 11000 11000 11000 75 7000 550 600 50/100 80/50 16600 28600 75
3000 12600 12600 11500 115 8000 600 650 50/100 80/50 19000 38000 76
4500 15500 15500 12500 132 8500 750 800 50/100 80/50 28000 58000 77
6000 18100 18100 13500 160 9150 900 1000 50/100 80/50 34000 64000 78
Base on inlet water temperature is 37°C outlet water temperature is 32°C and ambient wet bulb temperature is 28°C
FBNZ Single Cell - High Temperature Type
300 4000 4000 6500 7.5 2800 200 250 25/50 50/25 3500 5000 65
750 4900 4900 7000 7.5 3400 250 300 25/50 50/25 4350 5850 67
525 5500 5500 7500 11 4200 250 300 50/80 65/40 5500 7000 68
600 6300 6300 8000 18.5 4600 300 350 50/80 65/40 6500 8000 69
750 6300 6300 9000 22 5000 300 350 50/80 65/40 7500 10500 70
900 7200 7200 9500 30 5000 300 350 50/80 65/40 8500 11500 71
1050 7200 7200 10000 37 5000 300 350 50/80 65/40 9900 18000 72
1350 9400 9400 10500 45 6000 400 450 50/80 65/40 10900 19400 73
1500 10000 10000 11500 55 6000 500 550 50/100 80/50 14500 24000 74
1800 11000 11000 12000 75 7000 550 600 50/100 80/50 16600 28600 75
2550 12600 12600 13500 115 8000 600 650 50/100 80/50 19000 38000 76
3000 15500 15500 14000 132 8000 700 900 50/100 80/50 27000 57000 77
3900 15500 15500 14500 132 8500 750 800 50/100 80/50 28000 58000 77
5250 18100 18100 15500 160 9150 900 1000 50/100 80/50 34000 64000 78
Base on inlet water temperature is 43°C outlet water temperature is 33°C and ambient wet bulb temperature is 28°C
FBNG Single Cell - Super High Temperature Type
300 4900 4900 7000 7.5 3400 250 300 25/50 50/25 4350 5850 67
375 5500 5500 7500 11 4200 250 300 50/80 65/40 5500 7000 68
450 6300 6300 8000 18.5 4600 300 350 50/80 65/40 6500 8000 69
600 6300 6300 9000 22 5000 300 350 50/80 65/40 7500 10500 70
675 7200 7200 9500 30 5000 300 350 50/80 65/40 8500 11500 71
750 7200 7200 10000 37 5000 300 350 50/80 65/40 9900 18000 72
975 9400 9400 10500 45 6000 400 450 50/80 65/40 10900 19400 73
1200 10000 10000 11500 55 6000 500 550 50/100 80/50 14500 24000 74
1500 11000 11000 12000 75 7000 550 600 50/100 80/50 16600 28600 75
1950 12600 12600 13500 115 8000 600 650 50/100 80/50 19000 38000 76
2250 15500 15500 14400 132 8000 700 800 50/100 80/50 27000 57000 77
3000 15500 15500 14500 132 8500 750 800 50/100 80/50 28000 58000 77
3750 18100 18100 15500 160 9150 900 1000 50/100 80/50 34000 64000 78
Base on inlet water temperature is 60°C outlet water temperature is 35°C and ambient wet bulb temperature is 28°C
Note : Please kindly consult Super Tower Industries for other special temperature requirement.
Single Cell Counter-Flow Square Cooling Tower

FBND, FBNZ, FBNG


series
Foundation Drawing

FOUNDATION DIMENSIONS LOADING WEIGHT


MODELS
(MM) (KG)

FBND FBNZ FBNG L H I K X Y


200 4000 5500 1250 3750 300 1500
250 200 4000 5500 1250 3750 400 1600
300 250 200 4900 6000 1550 4650 500 2200
400 350 250 5500 6500 1780 5340 600 2500
500 400 300 6300 7000 2050 6150 700 3500
600 500 400 6300 7500 2050 6150 750 3700
700 600 450 7200 7500 2400 7200 800 4100
800 700 500 7200 8000 2400 7200 1200 5500
H - Height of cooling tower. ( ) - Recommended dimensions
Single Cell Counter-Flow Square Cooling Tower

FBND, FBNZ, FBNG


series
Foundation Drawing

FOUNDATION DIMENSIONS LOADING WEIGHT


MODELS
(MM) (KG)

FBND FBNZ FBNG L H K I J X Y Z


1000 900 650 9400 10500 9400 1680 2000 400 1800 7000
1200 1000 800 10000 11500 10000 2000 2200 500 2200 8000
1500 1200 1000 11000 12000 11000 2200 2400 600 2600 9000
2000 1700 1300 12600 13500 12600 2520 2800 700 3000 12000
3000 2600 2000 15500 14500 15500 3100 3500 1000 5000 20000
4000 3500 2500 18100 15500 18100 3620 4000 1100 5500 22000
H - Height of cooling tower. ( ) - Recommended dimensions
Standard Low Noise Counter-Flow Round Cooling Tower

BND
series
Standard Specifications – Part I
DIMENSION TOWER WEIGHT PIPING DIAMETER FOUNDATION
Motor Fan Fan Water Noise
Model Inlet Outlet Make Over
No.

415/50H Diameter Air Flow Pressure Drain Level


BND-t Casing High Dry Wet Pipe Pipe Up Flow Dimension Diameter NOS
H.P. mm ø cmm Kpa dB
Dmm ø Hmm ø Kg Kkg emm mm ø n
DNmm ø

1 BND-5t 0.25 720 1730 550 41 50 0.2 20 40 40 15 25 25 433 500 3 55

2 BND-10t 0.5 1020 1700 570 67 70 0.4 20 40 40 15 25 25 563 650 3 55

3 BND-15t 0.75 1020 1800 580 83 80 0.4 20 40 40 15 25 25 563 650 3 55

4 BND-20t 0.75 1300 1860 700 125 110 0.6 25 50 50 20 25 25 797 920 3 56

5 BND-30t 1.5 1300 1980 760 167 120 0.6 25 50 50 20 25 25 797 920 3 56

6 BND-40t 1.5 1500 2040 930 250 160 1.2 25 50 50 20 25 25 799 1130 5 57

7 BND-50t 1.5 1760 2320 870 330 185 1.2 25 80 80 20 25 25 990 1400 5 57

8 BND-60t 1.5 1760 2300 880 370 190 1.2 25 80 80 20 25 25 990 1400 5 57

9 BND-75t 2 2020 2400 1200 410 360 1.7 30 80 80 20 40 40 1216 1720 5 58

10 BND-100t 3 2620 2650 1490 625 560 2.1 30 100 100 25 40 40 1030 2060 7 60

11 BND-125t 3 2620 2700 1500 670 570 2.2 30 100 100 25 40 40 1030 2060 7 60

12 BND-150t 4 3040 3200 1800 830 870 3.1 40 125 125 25 50 50 1350 2700 7 61

13 BND-175t 5.5 3500 3300 1900 1040 1170 3.7 40 125 125 40 50 50 1125 2940 9 61

14 BND-200t 5.5 3500 3400 1990 1250 1590 4.0 40 150 150 40 50 50 1125 2940 9 62

15 BND-225t 5.5 3500 3400 2000 1330 1600 4.1 40 150 150 40 50 50 1125 2940 9 62

16 BND-250t 7.5 3500 3500 2100 1460 1700 4.5 40 150 150 40 50 50 1125 2940 9 62

17 BND-275t 7.5 4000 3800 2380 1670 2000 5.4 50 200 200 40 50 50 1335 3490 9 63

18 BND-300t 7.5 4000 3800 2400 1830 2100 5.5 50 200 200 40 50 50 1335 3490 9 63

19 BND-350t 7.5 4000 3900 2800 2080 2500 5.8 50 200 200 40 50 50 1335 3490 9 63

20 BND-400t 10 4900 3890 3390 2500 2900 7.6 50 250 250 50 80 80 1206 4660 13 64

21 BND-450t 10 4900 3900 3400 2670 3000 7.8 50 250 250 50 80 80 1260 4660 13 64

22 BND-500t 15 4900 4200 3600 2900 3100 8.3 50 250 250 50 80 80 1206 4660 13 64

23 BND-600t 20 5540 4400 4200 3300 4000 11.5 55 250 250 50 80 80 1385 5350 13 65

24 BND-700t 25 5540 4600 4200 3750 4500 11.9 55 250 250 50 80 80 1385 5350 13 65

25 BND-800t 25 6340 4890 5000 4100 5200 13.0 55 300 300 50 80 80 1200 6150 17 66

26 BND-900t 30 6340 4900 5000 5000 6200 14.1 55 300 300 50 80 80 1200 6150 17 66

27 BND-1000t 40 7200 5300 5000 5800 7500 19.5 70 300 300 50 80 80 1385 7100 17 67

28 BND-1200t 40 7200 5800 5000 6600 8500 20.5 70 300 300 50 80 80 1385 7100 17 67

29 BND-1500t 50 9000 8800 6000 8300 9800 28.5 90 400 400 50 80 80 1717 8800 17 68

30 BND-1800t 60 9600 9000 6000 10000 11500 32.5 100 500 500 80 100 100 1853 9500 17 69

31 BND-2200t 75 11600 9500 6000 12500 13500 36.5 110 500 500 80 100 100 2200 1130 17 70
Standard Low Noise Counter-Flow Round Cooling Tower

BND
series
Standard Specifications – Part II - Selection Chart -
WET BULB 27°C WATER FLOW RATE L/min WET BULB 28°C WATER FLOW RATE L/min

A B C D E F G H I J K L M N O P Q R MODEL

37 38 40 42 45 35 40 35 43 45 37 38 43 45 35 35 60 90 INLET TEMP.

32 32 32 32 32 30 30 29.5 33 35 32 32 33 35 29.5 30 35 40 OUTLET TEMP.

65 58 45 40 31 42 28 34 45 59 57 49 42 58 26 33 28 23 BND-5T

130 116 91 79 62 85 57 68 90 119 113 97 85 115 51 66 56 45 BND-10T

195 175 136 119 93 127 85 102 136 178 170 146 127 173 76 98 85 68 BND-15T

260 232 181 158 124 170 112 136 181 236 226 194 168 230 102 132 113 90 BND-20T

390 348 272 237 186 252 168 204 271 354 339 291 252 345 153 198 170 136 BND-30T

520 464 362 316 248 336 224 272 362 472 452 388 336 460 204 264 226 180 BND-40T

650 580 452 395 310 420 280 340 452 590 565 485 420 575 255 330 282 226 BND-50T

780 696 542 474 372 504 336 408 542 708 678 582 504 690 306 396 339 271 BND-60T

975 875 680 595 465 635 425 510 680 890 850 730 635 865 382 493 425 340 BND-75T

1300 1165 905 790 620 848 565 678 905 1185 1130 970 848 1150 510 655 565 452 BND-100T

1625 1450 1130 980 775 1060 705 845 1130 1480 1410 1210 1060 1438 635 818 705 564 BND-125T

1950 1745 1356 1185 930 1270 845 1020 1356 1780 1695 1460 1270 1725 760 980 847 678 BND-150T

2275 2040 1585 1385 1090 1485 990 1188 1585 2080 1980 1700 1485 2020 890 1150 990 792 BND-175T

2600 2330 1810 1580 1240 1695 1130 1355 1810 2370 2260 1940 1695 2305 1020 1310 1130 904 BND-200T

2925 2620 2040 1780 1400 1910 1270 1530 2040 2675 2545 2189 1910 2595 1145 1475 1272 1018 BND-225T

3250 2915 2265 1980 1555 2120 1415 1700 2265 2970 2830 2430 2120 2885 1270 1640 1415 1132 BND-250T

3575 3200 2490 2180 1710 2330 1555 1865 2490 3265 3110 2675 2330 3170 1400 1800 1555 1244 BND-275T

3900 3490 2710 2375 1965 2540 1695 2030 2710 3560 3390 2915 2540 3455 1525 1966 1695 1356 BND-300T

4550 4080 3170 2770 2180 2970 1980 2375 3170 4155 3960 3405 2970 4040 1780 2295 1980 1584 BND-350T

5200 4655 3615 3165 2485 3390 2260 2710 3615 4745 4520 3890 3390 4610 2035 2621 2260 1808 BND-400T

5850 5240 4070 3560 2800 3820 2545 3055 4070 5345 5090 4380 3820 5190 2290 2950 2545 2036 BND-450T

6500 5820 4520 3955 3105 4235 2825 3390 4520 5930 5650 4860 4240 5760 2540 3275 2825 2260 BND-500T

7800 6985 5425 4746 3729 5085 3390 4068 5425 7120 6780 5830 5085 6915 3050 3930 3390 2712 BND-600T

9100 8160 6340 5540 4360 5940 3960 4750 6340 8310 7920 6810 5940 8080 3560 4590 3960 3168 BND-700T

10400 9320 7240 6335 4980 6785 4525 5430 7240 9500 9050 7785 6785 9230 4075 5250 4525 3620 BND-800T

11700 10485 8145 7125 5600 7635 5090 6110 8145 10690 10180 8755 7635 10385 4580 5905 5090 4072 BND-900T

13000 11650 9048 7915 6220 8480 5655 6785 9045 11875 11310 9725 8480 11535 5090 6560 5655 4524 BND-1000T

15600 13975 10855 9500 7465 10175 6785 8140 10855 14245 13570 11670 10175 13840 6105 7870 6790 5428 BND-1200T

19500 17460 13560 11865 9320 12710 8475 10170 13560 17800 16950 14575 12710 17290 7625 9830 8475 6780 BND-1500T

23400 20970 16290 14250 11200 15270 10180 12220 16290 21380 20360 17510 15270 20770 9160 11810 10180 8144 BND-1800T

28600 25630 19910 17380 13640 18645 12430 14905 19910 26070 24860 21340 18645 25355 11220 14410 12430 9944 BND-2200T
Standard Low Noise Counter-Flow Round Cooling Tower

BND
series ①
Foundation And Structure
Drawing ② NO ITEM MATERIAL
1 MOTOR 415V
50HZ

③ 2 FAN BLADE ALUM ALLOY

④ 3 CASING FRP

4 SPRINKLER PIPE PVC

⑥ 5 SPRINKER HEAD ALUM ALLOY

⑦ 6 CENTER PIPE PVC

⑧ 7 INFILL PVC

⑨ 8 LADDER H.D.G.S.

⑩ 9 INFILL SUPPORT H.D.G.S.

⑪ 10 AIR INLET LOUVRE PP



11 CASING SUPPORT H.D.G.S.

12 WATER BASIN FRP

13 AUX. SUCTION TANK FRP

14 TOWER SUPPORT STRUCTURE H.D.G.S. or FRP

15 WATER INLET / OUTLET H.D.G.S.

H
Outlet

Inlet
O/F M/A
D Outlet Pipe
Inlet Pipe

Inlet Outlet Inlet Outlet Inlet Outlet

BND 5-350t BND 5-30t BND 40-75t BND 100-150t BND 175-350t

h = 300

Section A-A
H Outlet Outlet

Inlet Inlet
M/A Outlet Pipe h = 500
Inlet
D
Pipe

Section B-B

BND 400-2200t BND 400-700t BND 800-2200t


Standard Low Noise Counter-Flow Round Cooling Tower

BND
series
Noise Level Table
TESTING
POINT
STANDARD LOW NOISE SUPER LOW NOISE
MODEL
5 45 56 59 40 51 55 37 46 55
10 47 57 60 41 52 57 38 47 56
15 48 58 62 41 52 58 38 47 56
20 49 58 62 42 53 59 39 48 58
25 49 59 63 43 54 61 40 49 59
30 49 60 65 43 54 62 40 49 59
40 49 60 65 44 55 63 41 50 60
50 50 61 66 46 56.5 64 42 51 62
60 50 61 66 46 56.5 64 42 51 62
75 51 62 67 47 58 66 43 52 63
100 51 63.5 69 47 58 67 43 52 63
125 52 64.5 70 47.5 59 68 43 53 63
150 52 65 72 48 60 68 44 54 64
175 52 65 72 49 60.5 69.5 44 54 64
200 53 66 74 49 60.5 69.5 44 55 65
225 53 66 74 50 61 70 45 56 65
250 53 67 75 50 61 70 45.5 56 66
300 53 67.5 76 51 62 71 46 57 66
350 54 68 77 51 63 71 47 58 67
400 54 68 77 52 64 72 47 59 67
500 55 69 77 52 64 72 48 60 68
600 57 70.5 79 53 65 73 49 61 69
700 57 71 79 53 66.5 73.5 49 61 69
800 59 72 79.5 54 67.5 74 50 62.5 70
1000 60 73 81 54 68 75 50 63 70

 The testing point is for the comparison purpose between the


same amount cooling water.

①  The testing point is 1.5M from the ground and is at 2 times of


the tower diameter distance from the wall vertically and in the
air input direction.

 The testing point is at times of the output diameter distance


from the wind shaft in the 45° direction.


SUPER TANK SPECIFICATION
TYPE 1m Height 1.5m Height 2m Height 2.5m Height
NO.
L x W (mm) Volume (m³) Dry Wt (kg) Wet Wt (t) Volume (m³) Dry Wt (kg) Wet Wt (t) Volume (m³) Dry Wt (kg) Wet Wt (t) Volume (m³) Dry Wt (kg) Wet Wt (t)

1 1x1 1 105 1.1 2 215 2.2


2 2x1 2 165 2.2 3 230 3.2 4 330 4.3 5 505 5.5
3 3x1 3 220 3.2 6 450 6.4
4 2x2 4 245 4.3 6 340 6.3 8 480 9 10 750 11
5 3x2 6 330 6.3 9 455 10 12 635 13 15 995 16
6 4x2 8 410 9 16 920 17 20 1255 22
7 3x3 9 455 10 18 965 19
8 4x3 12 565 13 18 785 19 24 1030 26 30 1500 33
9 5x3 15 690 16 30 1235 33
10 6x3 18 805 19 27 1080 28 36 1420 39 45 2150 49
11 4x4 16 710 17 24 985 25 32 1305 35 40 1880 44
12 5x4 20 885 21 30 1165 32 40 1550 44 50 2250 55
13 6x4 24 1020 26 36 1350 39 48 1710 52 60 2590 66
14 5x5 25 1060 27 50 1780 56
15 6x5 30 1225 33 45 1595 48 60 2020 66 75 2950 84
16 7x5 35 70 2410 77
17 8x5 40 80 2950 88 100 3900 112
18 9x5 45 90 3050 99
19 10 x 5 50 100 3500 110 125 4400 135
20 6x6 36 72 2400 75 90 3400 99
21 7x6 42 84 2980 90 105 4000 115
22 8x6 48 96 3250 101 120 4300 140
23 9x6 54 108 3750 120 135 4700 155
24 10 x 6 60 120 3960 130 150 5100 170
25 7x7 49 98 3300 108
26 8x7 56 112 3800 122 140 4800 160
27 9x7 63 126 4100 136
28 10 x 7 70 140 4500 144 175 5700 195
29 8x8 64 128 4200 138 160 5300 180
30 9x8 72 144 4700 154 180 600 200
31 10 x 8 80 160 4990 175 200 6300 225
32 9x9 81 162 5080 177
33 10 x 9 90 180 5120 195 255 6900 255
34 10 x 10 100 200 5660 220 250 7300 280
35 12 x 10 120 240 6730 260 300 8600 340
36 15 x 10 150 300 8100 330 375 10600 405
37 18 x 10 180 360 9590 390 450 11500 490
38 20 x 10 200 400 10400 450 500 12900 560
SUPER TANK SPECIFICATION
3m Height 3.5m Height 4m Height Connection Pipe Size
Volume (m³) Dry Wt (kg) Wet Wt (t) Volume (m³) Dry Wt (kg) Wet Wt (t) Volume (m³) Dry Wt (kg) Wet Wt (t) Inlet Outlet Drain Overflow Warining

25 32 25 40 50
25 32 25 40 50
9 950 10 25 32 25 40 50
12 985 13 40 50 25 50 65
18 1325 19 21 1890 23 50 65 40 65 80
24 1660 26 28 2030 30 32 2240 35 50 65 40 65 80
27 1750 29 36 2310 40 65 80 50 80 80
36 2150 39 42 255 46 48 2800 56 65 80 50 80 80
45 2550 49 60 3290 67 80 100 50 100 100
54 2935 59 63 3465 69 72 3780 80 80 100 50 100 100
48 2505 53 56 3080 64 64 3360 71 80 100 50 100 100
60 3025 66 70 3605 77 80 3920 89 80 100 50 100 100
72 3400 79 84 4130 98 96 4480 106 100 150 80 150 150
75 3450 85 100 4550 112 100 150 80 150 150
90 3950 99 105 4795 118 120 5180 135 100 150 80 150 150
105 4500 115 140 5810 155 100 150 80 150 150
120 4740 135 140 5985 156 160 6440 177 100 150 80 150 150
135 5100 150 180 7070 199 150 200 100 200 150
150 5700 165 175 7175 195 200 7700 230 150 200 100 200 150
108 4700 118 126 5460 138 144 5880 160 150 200 100 200 150
126 4920 136 147 6125 170 168 6580 190 150 200 100 200 150
144 5300 154 168 6790 190 192 7280 202 150 200 100 200 150
162 5950 180 189 7455 210 216 7980 236 150 200 100 200 150
180 6500 198 210 8120 230 240 8680 265 150 200 100 200 150
147 5350 159 150 200 100 200 150
168 6050 190 196 7595 218 224 8120 250 150 200 100 200 150
189 6650 199 252 8890 277 150 200 100 200 150
210 7370 230 245 9065 265 280 9660 303 150 200 100 200 150
192 6750 212 224 8400 248 256 8960 286 150 200 100 200 150
216 7510 236 252 9205 277 288 9800 318 150 200 100 200 150
240 8150 264 280 10010 300 320 10640 360 150 200 100 200 150
243 8230 268 324 10710 370 150 200 100 200 150
270 8950 296 315 10955 345 360 11600 400 150 200 100 200 150
300 9600 330 350 11900 390 400 12600 450 150 200 100 200 150
360 11260 390 420 13790 465 480 14560 530 150 200 100 200 150
450 13500 490 525 16625 555 600 17500 670 150 200 100 200 150
540 15950 590 630 19460 670 720 20440 790 150 200 100 200 150
600 17400 660 700 21350 770 800 22400 890 150 200 100 200 150
Suitable Model Selection Chart

1000
900
Take the following operating conditions as an example: 800
700
Hot water temperature 37°C
600
Cold water temperature 32°C 500
Range (hot-cold water temp. difference) 5°C
400
Ambient wet-bulb temperature 27°C

Circulation water flow rate m² / h


Circulating water flow rate 450m³/h 300

How to read the chart 200

1 Trace up the Hot water temperature of 37°C vertically to find the intersecting 150
point 1 with the 27°C ambient wet-bulb temperature curve.
2 Shift the point 1 to the right to find the intersection point 2 with the 5°C range 100
curve. 90
80
3 Then trace up again from the point 2 to find the intersecting point 3 with the 70
450m³/h circulating water flow rate. 60

4 If point 3 falls on the curve of a model, select this model. If point 3 falls 50

between two curves, select the larger model. 40


5 Because point 3 falls between the curves of 500 & 600, the selection is model 30
600.
Remarks 20
1 For cooling tower hot water temperature exceeding 50°C, heat-resistant version
should be used (delivered by special order).
2 If suitable model cannot be found from the chart, please inquire us.

60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30
Hot water temperature °C
A INSTALLATION HANDING INSTRUCTIONS
1. LOCATION 3. PIPING
To keep the cooling tower in full swing, choose a a. The pipes above the cold water basin’s water
place according to the following conditions. level especially the horizontal line atop the
tower body should be as short as possible. This
a. Well- ventilated, clean. helps to keep backwater at minimum when the
cooling tower stops
b. Exhaust air from the cooling tower is not circulated
and sucked again into the tower. b. There are plural pipes leading to the distribution
basin. Be sure to equip a flow control valve with
c. Free from much dust and dirt, sulfurous acid and each of the hot water inlet pipes. The internal
other hazard gases; these are major cause to piping type is equipped with a simple flow
damage the refrigerator condenser. control valve. An overall flow control valve
should be equipped at the circulating water
d. Not in the vicinity of kitchen or restroom exhaust pump outlet.
ports, or ammonia type copying machine.
c. To fix the tower-top pipe supports, use
e. Not near smokestack or stovepipe, or radiant heat distribution basin mounting bolts. The bolts at
from any other heat source. fan side can be screwed from inside, while those
at louver side can be tightened after detaching
f. Open and not affected by sound echo. the style strip.

g. 2.7m or more space between the cooling tower air d. The inlet pipe should be positioned about
inlet and the wall or other barrier. 50mm below the cooling tower top deck.

2. PROCEDURE e. To prevent the make-up water inlet pipe from


a. Prepare the foundation, referring to the related damage by freezing in winter, equip a drain cock
drawings. at the bottom in between the valve and the
make-up water inlet pipe connection.
b. Make the foundation top even and level.

B BEFORE OPERATION
1. Turn the fan blade by hand to make sure the blade 5. Bring the circulating pump into full operation
tips are out of contact with the fan stack. and adjust the flow control valve so that the
water level of the distribution basin is well
2. Run the fan for a while and check for turning balanced. The circulating water flow rate is
direction (arrow-marked), unusual sound, excess than adjusted with the overall flow control
vibrations, etc. valve located at the circulating pump outlet.

3. Fill the cold water basin up to the top level of the 6. The ball tap of the automatic make-up water
overflow pipe. inlet pipe should be adjusted so that water
interrupted slightly below the overflow water
4. Run the circulating pump for a while to force air level.
out of the pipes until the pipes and cold water
basin are filled up with water. Be careful not to
allow air to be suck into the cooling water pipe.

SUPER TOWER INDUSTRIES Distributor :

Singapore Office:

Block 9002, Tampines Street 93


#04-44, Singapore 528836
TEL : (65) 6583-9587
FAX : (65) 6583-0450
WEBSITE : www.supertower.com.sg
EMAIL : sales@supertower.com.sg

You might also like