Wiring diagram Installation IQAN-MD3

Publ.no: HY33-8395-IS/UK
Ed. 01/2013

IQAN-MD3
levers and IQAN
sensors expansion unit

6 7 6 7

6
7
6
7

C2 C1

8
5
5
8

1 2 3 4
12 11 10 9
4
9
12 11 10
1 2 3

1 12 1 12

1 DIN-A / VIN-A 7 USB-D+ 1 -BAT 7 +RTC


2 DIN-B / VIN-B 8 +VREF 2 CAN-A-L 8 RS232 DATA OUT
3 DIN-C / VIN-C 9 DIN-E / VIN-E 3 CAN-B-L 9 CAN-C-H/Diag CAUTION
4 DIN-D / VIN-D 10 DIN-F / VIN-F 4 CAN-C-L/Diag 10 CAN-B-H Do not connect the module directly to the 80
5 -VREF 11 DIN-G / VIN-G 5 RS232 DATA IN 11 CAN-A-H USB port of your computer! 60
6 USB-D- 12 DOUT-A 6 ADDR-L* 12 +BAT • Possible “ground loops” can damage 40
your PC or the module. 20 -30 - +60C o
Mating connectors kit: 20073081 * for addressing in multi-master systems, • A USB isolation device should be used to 0
idTag is connected between +VREF and safely connect your PC to the module.
-20
-40
ADDR-L.
NOTICE -60
Connectors must be properly installed We recommend using a CAN interface -80
to meet environmental specification. instead of USB. Contact Parker for a list of
• Sealing plugs must be inserted in compatible USB to CAN adapters. (2004/108/EC)
unused pin positions.
• Both connectors must be installed.
WARNING
NOTICE FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR
Screw engagement must be 8-11 mm. Mv: 0.8 - 1.0 Nm SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
• Less engagement and the screw PT40 screw INJURY AND PROPERTY DAMAGE.
may not hold.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
• More engagement and the product and/or system options for further investigation by users having technical expertise. It is important that you analyze
housing may be damaged. 91 all aspects of your application, including consequences of any failure, and review the information concerning the product or
82
system in the current product catalogue. Due to the variety of operating conditions and applications for these products or
R8.0 max systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
ø4.5
96

8
11

For further information see:


HY33-8395-IB/UK Instructions IQAN-MD3

Eng. no: M5010047A


Rev. G
unit = mm

You might also like