F1-Footing Design

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 67

DESIGN OF FLAT FOOTING

CLIENT IMC KRMR


TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1923.99 (kN)
Mx , Mz 372.089 5.891 (kNm)
Fx , Fz 0.466 372.089 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 800 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 7.05
LENGTH , BREADTH OF FOOTING REQUIRED 2.66 2.66 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 3.35 3.35 (mm)
A - sqm AREA OF FOOTING PROVIDED 11.22
LOAD CASE 1
Load from Column 1923.99 (kN)
Weight of Foundation = 10% of Column Load 192.40 (kN)
Weight of Soil 211.61 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 2328.00 W (kN)
207.44 W/A (kN/sqm)
118.77 Mx/Zx (kN/sqm)
1.01 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 327.2 87.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 291.2 51.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 404.01 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 404.01 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 404.01 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 404.01 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 490.8 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1924.0 (kN)
FINAL Mx AND Mz 744.2 6.4 (kNm)
NET UPWARD PRESSURE 291.2 51.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1275 1275 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 236.7 236.7 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 355062551 355062551 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 327 327 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 800 800 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 740 740 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.65 0.65
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.12 0.12
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.15 0.15
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 1139 1139 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
SPACING 150 150 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 26 26
AREA OF STEEL PROVIDED 1608 1608 (sqmm)
pt PROVIDED 0.22 0.22
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 3350 740 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 3350 740 (mm)
SF AT d FROMFACE OF COLUMN 156 28 (kN)
Vu 233705 41457 (kN)
touV = Vux/Bd , Vuy/Bd 0.32 0.06 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.22 0.22
Beta VALUE ALONG X-DIR Y-DIR 13.35 13.35
Final Beta VALUE ALONG X-DIR Y-DIR 13.35 13.35
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.34 0.34 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 4558400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 2371600 (sqmm)
Pu1 2886 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2886 (kN)
p(avg) 207 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 2394 (kN)
touV 0.53 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 3350 3350 (mm)
TOTAL DEPTH PROVIDED 800 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1623.505 (kN)
Mx , Mz 306.356 7.688 (kNm)
Fx , Fz 0.466 306.356 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 800 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.95
LENGTH , BREADTH OF FOOTING REQUIRED 2.44 2.44 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 3.10 3.10 (mm)
A - sqm AREA OF FOOTING PROVIDED 9.61
LOAD CASE 1
Load from Column 1623.51 (kN)
Weight of Foundation = 10% of Column Load 162.35 (kN)
Weight of Soil 183.61 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1969.47 W (kN)
204.94 W/A (kN/sqm)
123.40 Mx/Zx (kN/sqm)
1.64 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 330.0 79.9 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 294.0 43.9
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 345.96 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 345.96 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 345.96 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 345.96 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 495.0 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1623.5 (kN)
FINAL Mx AND Mz 612.7 8.2 (kNm)
NET UPWARD PRESSURE 294.0 43.9 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1150 1150 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 194.4 194.4 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 291594852 291594852 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 296 296 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 700 700 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 640 640 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.71 0.71
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.13 0.13
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.17 0.17
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 1085 1085 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
SPACING 185 185 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 24 24
AREA OF STEEL PROVIDED 1608 1608 (sqmm)
pt PROVIDED 0.25 0.25
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 3100 640 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 3100 640 (mm)
SF AT d FROMFACE OF COLUMN 150 22 (kN)
Vu 224897 33580 (kN)
touV = Vux/Bd , Vuy/Bd 0.35 0.05 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.25 0.25
Beta VALUE ALONG X-DIR Y-DIR 11.55 11.55
Final Beta VALUE ALONG X-DIR Y-DIR 11.55 11.55
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.37 0.37 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 3686400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 2073600 (sqmm)
Pu1 2435 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2435 (kN)
p(avg) 205 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 2010 (kN)
touV 0.55 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 3100 3100 (mm)
TOTAL DEPTH PROVIDED 700 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1413.251 (kN)
Mx , Mz 278.324 6.385 (kNm)
Fx , Fz 0.466 278.324 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 650 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.18
LENGTH , BREADTH OF FOOTING REQUIRED 2.28 2.28 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.95 2.95 (mm)
A - sqm AREA OF FOOTING PROVIDED 8.70
LOAD CASE 1
Load from Column 1413.25 (kN)
Weight of Foundation = 10% of Column Load 141.33 (kN)
Weight of Soil 171.96 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1726.54 W (kN)
198.40 W/A (kN/sqm)
130.10 Mx/Zx (kN/sqm)
1.60 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 330.1 66.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 294.1 30.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 313.29 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 313.29 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 313.29 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 313.29 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 495.1 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1413.3 (kN)
FINAL Mx AND Mz 556.6 6.9 (kNm)
NET UPWARD PRESSURE 294.1 30.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1150 1075 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 194.5 169.9 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 291704216 254896548 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 296 277 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 700 700 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 640 640 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.71 0.62
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.13 0.11
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.17 0.15
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 1085 944 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
SPACING 185 213 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 23 23
AREA OF STEEL PROVIDED 1608 1608 (sqmm)
pt PROVIDED 0.25 0.25
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2950 640 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2950 640 (mm)
SF AT d FROMFACE OF COLUMN 150 13 (kN)
Vu 224982 20031 (kN)
touV = Vux/Bd , Vuy/Bd 0.35 0.03 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.25 0.25
Beta VALUE ALONG X-DIR Y-DIR 11.55 11.55
Final Beta VALUE ALONG X-DIR Y-DIR 11.55 11.55
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.37 0.37 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 3494400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1857600 (sqmm)
Pu1 2120 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2120 (kN)
p(avg) 198 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1751 (kN)
touV 0.50 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2950 2950 (mm)
TOTAL DEPTH PROVIDED 700 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 16 16 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1407.875 (kN)
Mx , Mz 5.241 104.587 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 650 650 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.16
LENGTH , BREADTH OF FOOTING REQUIRED 2.27 2.27 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.50 2.50 (mm)
A - sqm AREA OF FOOTING PROVIDED 6.25
LOAD CASE 1
Load from Column 1407.88 (kN)
Weight of Foundation = 10% of Column Load 140.79 (kN)
Weight of Soil 84.21 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1632.88 W (kN)
261.26 W/A (kN/sqm)
2.06 Mx/Zx (kN/sqm)
40.34 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 303.7 218.9 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 267.7 182.9
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 225.00 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 225.00 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 225.00 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 225.00 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 455.5 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1407.9 (kN)
FINAL Mx AND Mz 5.4 105.1 (kNm)
NET UPWARD PRESSURE 267.7 182.9 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 925 925 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 114.5 114.5 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 171765233 171765233 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 227 227 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 600 600 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 540 540 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.59 0.59
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.11 0.11
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.14
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 753 753 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 150 150 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 19 19
AREA OF STEEL PROVIDED 905 905 (sqmm)
pt PROVIDED 0.17 0.17
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2500 540 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2500 540 (mm)
SF AT d FROMFACE OF COLUMN 103 70 (kN)
Vu 154576 105599 (kN)
touV = Vux/Bd , Vuy/Bd 0.29 0.20 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.17 0.17
Beta VALUE ALONG X-DIR Y-DIR 17.32 17.32
Final Beta VALUE ALONG X-DIR Y-DIR 17.32 17.32
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.31 0.31 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2570400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1416100 (sqmm)
Pu1 2112 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2112 (kN)
p(avg) 261 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1742 (kN)
touV 0.68 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2500 2500 (mm)
TOTAL DEPTH PROVIDED 600 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1176.543 (kN)
Mx , Mz 0.793 117.857 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 600 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 4.31
LENGTH , BREADTH OF FOOTING REQUIRED 2.08 2.08 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.30 2.30 (mm)
A - sqm AREA OF FOOTING PROVIDED 5.29
LOAD CASE 1
Load from Column 1176.54 (kN)
Weight of Foundation = 10% of Column Load 117.65 (kN)
Weight of Soil 72.79 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1366.98 W (kN)
258.41 W/A (kN/sqm)
0.46 Mx/Zx (kN/sqm)
58.35 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 317.2 199.6 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 281.2 163.6
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 190.44 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 190.44 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 190.44 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 190.44 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 475.8 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1176.5 (kN)
FINAL Mx AND Mz 0.9 118.3 (kNm)
NET UPWARD PRESSURE 281.2 163.6 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 850 850 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 101.6 101.6 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 152383645 152383645 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 214 214 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.63 0.63
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.12 0.12
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.15 0.15
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 737 737 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 153 153 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 18 18
AREA OF STEEL PROVIDED 905 905 (sqmm)
pt PROVIDED 0.18 0.18
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2300 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2300 490 (mm)
SF AT d FROMFACE OF COLUMN 101 59 (kN)
Vu 151856 88345 (kN)
touV = Vux/Bd , Vuy/Bd 0.31 0.18 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.18 0.18
Beta VALUE ALONG X-DIR Y-DIR 15.72 15.72
Final Beta VALUE ALONG X-DIR Y-DIR 15.72 15.72
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.32 0.32 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2136400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1188100 (sqmm)
Pu1 1765 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1765 (kN)
p(avg) 258 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1458 (kN)
touV 0.68 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2300 2300 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 915.386 (kN)
Mx , Mz 2.621 116.3 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 530 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 3.36
LENGTH , BREADTH OF FOOTING REQUIRED 1.83 1.83 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.10 2.10 (mm)
A - sqm AREA OF FOOTING PROVIDED 4.41
LOAD CASE 1
Load from Column 915.39 (kN)
Weight of Foundation = 10% of Column Load 91.54 (kN)
Weight of Soil 67.22 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1074.15 W (kN)
243.57 W/A (kN/sqm)
1.78 Mx/Zx (kN/sqm)
75.65 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 321.0 166.1 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 285.0 130.1
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 158.76 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 158.76 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 158.76 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 158.76 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 481.5 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 915.4 (kN)
FINAL Mx AND Mz 2.8 116.8 (kNm)
NET UPWARD PRESSURE 285.0 130.1 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 785 750 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 87.8 80.2 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 131720669 120236726 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 199 190 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.55 0.50
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.10 0.09
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.13 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 635 588 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 178 192 (mm)
SPACING PROVIDED 150 150 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 13 13
AREA OF STEEL PROVIDED 754 754 (sqmm)
pt PROVIDED 0.15 0.15
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2100 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2100 490 (mm)
SF AT d FROMFACE OF COLUMN 84 34 (kN)
Vu 126115 50753 (kN)
touV = Vux/Bd , Vuy/Bd 0.26 0.10 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.15 0.15
Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Final Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.29 0.29 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2067800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1111800 (sqmm)
Pu1 1373 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1373 (kN)
p(avg) 244 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1102 (kN)
touV 0.53 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2100 2100 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 150 150 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 678.355 (kN)
Mx , Mz 8.382 97.607 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 450 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 2.49
LENGTH , BREADTH OF FOOTING REQUIRED 1.58 1.58 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 1.90 1.90 (mm)
A - sqm AREA OF FOOTING PROVIDED 3.61
LOAD CASE 1
Load from Column 678.36 (kN)
Weight of Foundation = 10% of Column Load 67.84 (kN)
Weight of Soil 62.12 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 808.32 W (kN)
223.91 W/A (kN/sqm)
7.45 Mx/Zx (kN/sqm)
85.79 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 317.2 130.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 281.2 94.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 129.96 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 129.96 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 129.96 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 129.96 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 475.7 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 678.4 (kN)
FINAL Mx AND Mz 8.5 98.1 (kNm)
NET UPWARD PRESSURE 281.2 94.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 725 650 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 73.9 59.4 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 110834639 89089436 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 183 164 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 500 500 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 440 440 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.57 0.46
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.11 0.08
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 595 528 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
SPACING 132 149 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 14 14
AREA OF STEEL PROVIDED 628 628 (sqmm)
pt PROVIDED 0.14 0.14
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 1900 440 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 1900 440 (mm)
SF AT d FROMFACE OF COLUMN 80 20 (kN)
Vu 120192 29821 (kN)
touV = Vux/Bd , Vuy/Bd 0.27 0.07 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.14
Beta VALUE ALONG X-DIR Y-DIR 20.33 20.33
Final Beta VALUE ALONG X-DIR Y-DIR 20.33 20.33
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.28 0.28 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 1698400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 925600 (sqmm)
Pu1 1018 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1018 (kN)
p(avg) 224 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 810 (kN)
touV 0.48 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 1900 1900 (mm)
TOTAL DEPTH PROVIDED 500 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 436.996 (kN)
Mx , Mz 1.211 90.875 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 450 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 1.60
LENGTH , BREADTH OF FOOTING REQUIRED 1.27 1.27 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 1.65 1.65 (mm)
A - sqm AREA OF FOOTING PROVIDED 2.72
LOAD CASE 1
Load from Column 437.00 (kN)
Weight of Foundation = 10% of Column Load 43.70 (kN)
Weight of Soil 54.31 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 535.01 W (kN)
196.51 W/A (kN/sqm)
1.80 Mx/Zx (kN/sqm)
122.00 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 320.3 72.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 284.3 36.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 98.01 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 98.01 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 98.01 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 98.01 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 480.5 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 437.0 (kN)
FINAL Mx AND Mz 1.3 91.3 (kNm)
NET UPWARD PRESSURE 284.3 36.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 600 525 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 51.2 39.2 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 76763901 58772362 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 152 133 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 450 450 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 390 390 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.50 0.39
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.09 0.07
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 468 468 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
SPACING 168 168 (mm)
SPACING PROVIDED 150 150 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 10 10
AREA OF STEEL PROVIDED 524 524 (sqmm)
pt PROVIDED 0.13 0.13
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 1650 390 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 1650 390 (mm)
SF AT d FROMFACE OF COLUMN 60 5 (kN)
Vu 89558 7435 (kN)
touV = Vux/Bd , Vuy/Bd 0.23 0.02 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.13 0.13
Beta VALUE ALONG X-DIR Y-DIR 21.62 21.62
Final Beta VALUE ALONG X-DIR Y-DIR 21.62 21.62
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.28 0.28 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 1427400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 831600 (sqmm)
Pu1 655 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 655 (kN)
p(avg) 197 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 492 (kN)
touV 0.34 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 1650 1650 (mm)
TOTAL DEPTH PROVIDED 450 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 150 150 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1393.833 (kN)
Mx , Mz 174.214 0.859 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 800 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.11
LENGTH , BREADTH OF FOOTING REQUIRED 2.26 2.26 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.60 2.60 (mm)
A - sqm AREA OF FOOTING PROVIDED 6.76
LOAD CASE 1
Load from Column 1393.83 (kN)
Weight of Foundation = 10% of Column Load 139.38 (kN)
Weight of Soil 103.98 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1637.19 W (kN)
242.19 W/A (kN/sqm)
59.52 Mx/Zx (kN/sqm)
0.45 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 302.2 182.2 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 266.2 146.2
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 243.36 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 243.36 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 243.36 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 243.36 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 453.2 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1393.8 (kN)
FINAL Mx AND Mz 174.3 1.3 (kNm)
NET UPWARD PRESSURE 266.2 146.2 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 900 900 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 107.8 107.8 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 161691358 161691358 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 221 221 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 700 700 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 640 640 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.39 0.39
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.07 0.07
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 768 768 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 147 147 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 20 20
AREA OF STEEL PROVIDED 905 905 (sqmm)
pt PROVIDED 0.14 0.14
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2600 640 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2600 640 (mm)
SF AT d FROMFACE OF COLUMN 69 38 (kN)
Vu 103802 57025 (kN)
touV = Vux/Bd , Vuy/Bd 0.16 0.09 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.14
Beta VALUE ALONG X-DIR Y-DIR 20.53 20.53
Final Beta VALUE ALONG X-DIR Y-DIR 20.53 20.53
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.28 0.28 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 3686400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 2073600 (sqmm)
Pu1 2091 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2091 (kN)
p(avg) 242 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1589 (kN)
touV 0.43 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2600 2600 (mm)
TOTAL DEPTH PROVIDED 700 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1256.168 (kN)
Mx , Mz 117.163 0.774 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 600 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 4.61
LENGTH , BREADTH OF FOOTING REQUIRED 2.15 2.15 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.35 2.35 (mm)
A - sqm AREA OF FOOTING PROVIDED 5.52
LOAD CASE 1
Load from Column 1256.17 (kN)
Weight of Foundation = 10% of Column Load 125.62 (kN)
Weight of Soil 73.19 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1454.98 W (kN)
263.46 W/A (kN/sqm)
54.23 Mx/Zx (kN/sqm)
0.57 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 318.3 208.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 282.3 172.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 198.81 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 198.81 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 198.81 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 198.81 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 477.4 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1256.2 (kN)
FINAL Mx AND Mz 117.3 1.2 (kNm)
NET UPWARD PRESSURE 282.3 172.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 875 875 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 108.1 108.1 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 162082604 162082604 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 221 221 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 600 600 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 540 540 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.56 0.56
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.10 0.10
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.13 0.13
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 709 709 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 160 160 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 18 18
AREA OF STEEL PROVIDED 905 905 (sqmm)
pt PROVIDED 0.17 0.17
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2350 540 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2350 540 (mm)
SF AT d FROMFACE OF COLUMN 95 58 (kN)
Vu 141839 86762 (kN)
touV = Vux/Bd , Vuy/Bd 0.26 0.16 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.17 0.17
Beta VALUE ALONG X-DIR Y-DIR 17.32 17.32
Final Beta VALUE ALONG X-DIR Y-DIR 17.32 17.32
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.31 0.31 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2462400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1299600 (sqmm)
Pu1 1884 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1884 (kN)
p(avg) 263 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1542 (kN)
touV 0.63 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2350 2350 (mm)
TOTAL DEPTH PROVIDED 600 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1665.388 (kN)
Mx , Mz 11.764 261.712 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 650 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 6.11
LENGTH , BREADTH OF FOOTING REQUIRED 2.47 2.47 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.75 2.75 (mm)
A - sqm AREA OF FOOTING PROVIDED 7.56
LOAD CASE 1
Load from Column 1665.39 (kN)
Weight of Foundation = 10% of Column Load 166.54 (kN)
Weight of Soil 105.71 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1937.64 W (kN)
256.22 W/A (kN/sqm)
3.43 Mx/Zx (kN/sqm)
75.64 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 335.3 177.1 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 299.3 141.1
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 272.25 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 272.25 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 272.25 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 272.25 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 502.9 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1665.4 (kN)
FINAL Mx AND Mz 11.9 262.2 (kNm)
NET UPWARD PRESSURE 299.3 141.1 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1050 975 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 165.0 142.3 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 247474476 213383604 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 273 253 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 700 700 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 640 640 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.60 0.52
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.11 0.10
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 916 786 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 124 144 (mm)
SPACING PROVIDED 100 100 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 27 27
AREA OF STEEL PROVIDED 1131 1131 (sqmm)
pt PROVIDED 0.18 0.18
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2750 640 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2750 640 (mm)
SF AT d FROMFACE OF COLUMN 123 47 (kN)
Vu 184063 70925 (kN)
touV = Vux/Bd , Vuy/Bd 0.29 0.11 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.18 0.18
Beta VALUE ALONG X-DIR Y-DIR 16.43 16.43
Final Beta VALUE ALONG X-DIR Y-DIR 16.43 16.43
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.31 0.31 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 3494400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1857600 (sqmm)
Pu1 2498 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2498 (kN)
p(avg) 256 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 2022 (kN)
touV 0.58 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2750 2750 (mm)
TOTAL DEPTH PROVIDED 700 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 100 100 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 300 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 336 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 1454.031 (kN)
Mx , Mz 6.409 253.421 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 600 800 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.33
LENGTH , BREADTH OF FOOTING REQUIRED 2.31 2.31 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.65 2.65 (mm)
A - sqm AREA OF FOOTING PROVIDED 7.02
LOAD CASE 1
Load from Column 1454.03 (kN)
Weight of Foundation = 10% of Column Load 145.40 (kN)
Weight of Soil 107.41 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1706.84 W (kN)
243.05 W/A (kN/sqm)
2.11 Mx/Zx (kN/sqm)
81.86 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 327.0 159.1 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 291.0 123.1
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 252.81 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 252.81 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 252.81 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 252.81 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 490.5 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 1454.0 (kN)
FINAL Mx AND Mz 6.5 253.9 (kNm)
NET UPWARD PRESSURE 291.0 123.1 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1025 925 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 152.9 124.5 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 229314203 186752614 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 263 237 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.96 0.78
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.18 0.14
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.23 0.19
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 1128 910 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
SPACING 70 86 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING REVISE REVISE
no. BARS IN EACH DIRECTION 20 20
AREA OF STEEL PROVIDED 628 628 (sqmm)
pt PROVIDED 0.13 0.13
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2650 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2650 490 (mm)
SF AT d FROMFACE OF COLUMN 156 54 (kN)
Vu 233543 80314 (kN)
touV = Vux/Bd , Vuy/Bd 0.48 0.16 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.13 0.13
Beta VALUE ALONG X-DIR Y-DIR 22.64 22.64
Final Beta VALUE ALONG X-DIR Y-DIR 22.64 22.64
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.27 0.27 (MPa)
CHECK FOR SHEAR REVISE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2332400 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1406100 (sqmm)
Pu1 2181 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 2181 (kN)
p(avg) 243 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1839 (kN)
touV 0.79 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2650 2650 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 150 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 186 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 467.683 (kN)
Mx , Mz 30.674 6.097 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 380 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 3.43
LENGTH , BREADTH OF FOOTING REQUIRED 1.85 1.85 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.10 2.10 (mm)
A - sqm AREA OF FOOTING PROVIDED 4.41
LOAD CASE 1
Load from Column 467.68 (kN)
Weight of Foundation = 10% of Column Load 46.77 (kN)
Weight of Soil 111.99 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 626.44 W (kN)
142.05 W/A (kN/sqm)
19.96 Mx/Zx (kN/sqm)
4.25 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 166.3 117.8 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 130.3 81.8
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 158.76 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 158.76 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 158.76 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 158.76 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 249.4 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 467.7 (kN)
FINAL Mx AND Mz 30.8 6.6 (kNm)
NET UPWARD PRESSURE 130.3 81.8 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 860 750 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 48.2 36.6 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 72256566 54954460 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 147 129 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 500 500 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 440 440 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.37 0.28
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.07 0.05
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 528 528 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
SPACING 149 149 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 16 16
AREA OF STEEL PROVIDED 628 628 (sqmm)
pt PROVIDED 0.14 0.14
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2100 440 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2100 440 (mm)
SF AT d FROMFACE OF COLUMN 55 25 (kN)
Vu 82065 38055 (kN)
touV = Vux/Bd , Vuy/Bd 0.19 0.09 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.14
Beta VALUE ALONG X-DIR Y-DIR 20.33 20.33
Final Beta VALUE ALONG X-DIR Y-DIR 20.33 20.33
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.28 0.28 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 1636800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 852800 (sqmm)
Pu1 702 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 702 (kN)
p(avg) 142 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 580 (kN)
touV 0.35 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2100 2100 (mm)
TOTAL DEPTH PROVIDED 500 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 150 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 186 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 914.03 (kN)
Mx , Mz 13.235 13.235 (kNm)
Fx , Fz 0.466 52.234 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 380 600 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 6.70
LENGTH , BREADTH OF FOOTING REQUIRED 2.59 2.59 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.50 3.30 (mm)
A - sqm AREA OF FOOTING PROVIDED 8.25
LOAD CASE 1
Load from Column 914.03 (kN)
Weight of Foundation = 10% of Column Load 91.40 (kN)
Weight of Soil 205.60 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1211.03 W (kN)
146.79 W/A (kN/sqm)
14.43 Mx/Zx (kN/sqm)
3.99 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 165.2 128.4 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 129.2 92.4
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 297.00 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 297.00 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 297.00 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 297.00 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 247.8 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 914.0 (kN)
FINAL Mx AND Mz 65.5 13.7 (kNm)
NET UPWARD PRESSURE 129.2 92.4 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1060 1350 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 72.6 117.7 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 108881635 176608028 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 181 230 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.45 0.74
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.08 0.14
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.18
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 588 859 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 192 132 (mm)
SPACING PROVIDED 125 125 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 19 26
AREA OF STEEL PROVIDED 905 905 (sqmm)
pt PROVIDED 0.18 0.18
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2500 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 3300 490 (mm)
SF AT d FROMFACE OF COLUMN 74 79 (kN)
Vu 110471 119167 (kN)
touV = Vux/Bd , Vuy/Bd 0.23 0.24 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.18 0.18
Beta VALUE ALONG X-DIR Y-DIR 15.72 15.72
Final Beta VALUE ALONG X-DIR Y-DIR 15.72 15.72
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.32 0.32 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 1920800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 948300 (sqmm)
Pu1 1371 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1371 (kN)
p(avg) 147 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1232 (kN)
touV 0.64 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2500 3300 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 125 125 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 150 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 186 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 413.374 (kN)
Mx , Mz 2.396 21.886 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 230 450 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 3.03
LENGTH , BREADTH OF FOOTING REQUIRED 1.74 1.74 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 1.80 2.10 (mm)
A - sqm AREA OF FOOTING PROVIDED 3.78
LOAD CASE 1
Load from Column 413.37 (kN)
Weight of Foundation = 10% of Column Load 41.34 (kN)
Weight of Soil 94.74 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 549.45 W (kN)
145.36 W/A (kN/sqm)
1.91 Mx/Zx (kN/sqm)
19.71 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 167.0 123.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 131.0 87.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 136.08 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 136.08 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 136.08 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 136.08 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 250.5 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 413.4 (kN)
FINAL Mx AND Mz 2.5 22.4 (kNm)
NET UPWARD PRESSURE 131.0 87.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 785 825 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 40.4 44.6 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 60535454 66861850 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 135 142 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 450 450 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 390 390 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.40 0.44
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.07 0.08
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 468 468 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
SPACING 168 168 (mm)
SPACING PROVIDED 150 150 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 11 13
AREA OF STEEL PROVIDED 524 524 (sqmm)
pt PROVIDED 0.13 0.13
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 1800 390 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2100 390 (mm)
SF AT d FROMFACE OF COLUMN 52 38 (kN)
Vu 77606 57247 (kN)
touV = Vux/Bd , Vuy/Bd 0.20 0.15 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.13 0.13
Beta VALUE ALONG X-DIR Y-DIR 21.62 21.62
Final Beta VALUE ALONG X-DIR Y-DIR 21.62 21.62
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.28 0.28 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 1138800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 520800 (sqmm)
Pu1 620 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 620 (kN)
p(avg) 145 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 544 (kN)
touV 0.48 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 1800 2100 (mm)
TOTAL DEPTH PROVIDED 450 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 10 10 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 150 150 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 150 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 186 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 564.259 (kN)
Mx , Mz 0.276 133.217 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 380 750 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 4.14
LENGTH , BREADTH OF FOOTING REQUIRED 2.03 2.03 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.60 2.60 (mm)
A - sqm AREA OF FOOTING PROVIDED 6.76
LOAD CASE 1
Load from Column 564.26 (kN)
Weight of Foundation = 10% of Column Load 56.43 (kN)
Weight of Soil 186.93 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 807.62 W (kN)
119.47 W/A (kN/sqm)
0.14 Mx/Zx (kN/sqm)
45.64 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 165.2 73.7 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 129.2 37.7
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 243.36 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 243.36 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 243.36 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 243.36 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 247.9 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 564.3 (kN)
FINAL Mx AND Mz 0.4 133.7 (kNm)
NET UPWARD PRESSURE 129.2 37.7 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1110 925 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 79.6 55.3 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 119433192 82939717 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 190 158 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.50 0.35
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.09 0.06
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.12 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 588 588 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 192 192 (mm)
SPACING PROVIDED 150 150 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 17 17
AREA OF STEEL PROVIDED 754 754 (sqmm)
pt PROVIDED 0.15 0.15
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2600 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2600 490 (mm)
SF AT d FROMFACE OF COLUMN 80 16 (kN)
Vu 120199 24596 (kN)
touV = Vux/Bd , Vuy/Bd 0.25 0.05 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.15 0.15
Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Final Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.29 0.29 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2067800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1078800 (sqmm)
Pu1 846 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 846 (kN)
p(avg) 119 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 718 (kN)
touV 0.35 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2600 2600 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 150 150 (mm)

E N D

56
DESIGN OF FLAT FOOTING
BODHAN
CLIENT HOSTEL
BUILDING
TYPE F1
NODE NO.S
Dt. 4/14/2022
INPUT DATA
Fck , Fy GRADE OF CONC., STEEL 25 500 (MPa)
Q -LIMIT 3.325
S.B.C.SOIL 150 (kN/sqm)
Total Depth of Footing below GL 2 m
Unit Weight of Soil 18 w (kN/sqm)
Gross SBC = Net SBC + (Height * Unit wt.) 186 (kN/sqm)

LOAD CASE:1.0(D+L)
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 766.295 (kN)
Mx , Mz 10.097 105.748 (kNm)
Fx , Fz 0.466 0.134 (kN)
PARTIAL SAFETY FACTOR 1.5

LOAD CASE 2:
P (Fy)AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LOAD CASE3::
P (Fy) AXIAL LOAD (WITHOUT Wt. OF FOOTING and SOIL.) 0 (kN)
Mx , Mz 0 0 (kNm)
Fx , Fz 0 0 (kN)
PARTIAL SAFETY FACTOR 0

LENGTH , BREADTH OF COLUMN/PEDESTAL 380 750 (sqmm)


A - sqm AREA OF FOOTING REQUIRED 5.62
LENGTH , BREADTH OF FOOTING REQUIRED 2.37 2.37 (mm)
LENGTH , BREADTH OF FOOTING PROVIDED 2.80 2.80 (mm)
A - sqm AREA OF FOOTING PROVIDED 7.84
LOAD CASE 1
Load from Column 766.30 (kN)
Weight of Foundation = 10% of Column Load 76.63 (kN)
Weight of Soil 205.61 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 1048.54 W (kN)
133.74 W/A (kN/sqm)
2.80 Mx/Zx (kN/sqm)
29.03 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 165.6 101.9 (kN/sqm)
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 129.6 65.9
LOAD CASE 2
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 282.24 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 282.24 W (kN)

56
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)

56
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0

LOAD CASE 3
Load from Column 0.00 (kN)
Weight of Foundation = 10% of Column Load 0.00 (kN)
Weight of Soil 282.24 (kN)
Total weight on foundation = Fy + 0.1 Fy +[(L*B*H*w) - 0.1Fy] 282.24 W (kN)
36.0 W/A (kN/sqm)
0.0 Mx/Zx (kN/sqm)
0.0 Mz/Zz (kN/sqm)
P max P min - MAX. PR., MIN. PR. OF SOIL 36.0 36.0
CHECK FOR SBC AND NEGATIVE PRESSURE SAFE SAFE
Pnet - NET DESIGN PRESSURE 0.0 0.0
FACTORED PRESSURES
CASE 1 248.4 (kN/sqm)
CASE 2 0.0 (kN/sqm)
CASE 3 0.0 (kN/sqm)

GUIDING LOAD CASE CASE1


DESIGN LOADS AND MOMENTS
P - kN AXIAL LOAD 766.3 (kN)
FINAL Mx AND Mz 10.2 106.2 (kNm)
NET UPWARD PRESSURE 129.6 65.9 (kN/sqm)
PARTIAL SAFETY FACTOR 1.5
OFFSET - ALONG X-DIR Y-DIR 1210 1025 (mm)
Mx , My (UNFACTORED B.M ALONG X- DIR , Y -DIR) 94.9 68.1 (kNm)
Mux , Muy (FACTORED B.M ALONG X- DIR , Y -DIR) 142276345 102096226 (Nmm)
d - EFFECTIVE DEPTH REQUIRED ALONG X-DIR Y-DIR 207 175 (mm)
CLEAR COVER PROVIDED 50 50 (mm)
D - TOTAL DEPTH PROVIDED ALONG X-DIR Y-DIR 550 550 (mm)
d - EFFECTIVE DEPTH PROVIDED ALONG X-DIR Y-DIR 490 490 (mm)
CHECK FOR EFFECTIVE DEPTH OK OK
Mu/bdd 0.59 0.43
CHECK FOR Mu LIMIT OK OK
CALCULATION OF REINFORCEMENT
X=4.6*Mu/Fck*B*d*d 0.11 0.08
Y= 0.5*Fck/Fy 0.03 0.03
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.14 0.12
Astx, Asty AREA OF STEEL REQUD ALONG X-DIR , Y-DIR 687 588 (sqmm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
SPACING 165 192 (mm)
SPACING PROVIDED 150 150 (mm)
CHECK FOR SPACING OK OK
no. BARS IN EACH DIRECTION 18 18
AREA OF STEEL PROVIDED 754 754 (sqmm)
pt PROVIDED 0.15 0.15
CHECK FOR ONE WAY SHEAR
AT `d ' FROM FACE OF COLUMN/PEDESTAL
B, d - WIDTH, DEPTH OF FOOTING ALONG X-DIR 2800 490 (mm)
B, d - WIDTH, DEPTH OF FOOTING ALONG Y-DIR 2800 490 (mm)
SF AT d FROMFACE OF COLUMN 93 35 (kN)
Vu 139934 52896 (kN)
touV = Vux/Bd , Vuy/Bd 0.29 0.11 (MPa)

56
ptx , pty - % OF STEEL ALONG X-DIR Y-DIR 0.15 0.15
Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Final Beta VALUE ALONG X-DIR Y-DIR 18.86 18.86
Toucx, Toucy ALLOWABLE ALONG X-DIR Y-DIR 0.29 0.29 (MPa)
CHECK FOR SHEAR SAFE SAFE
IF pt IS TO BE INCREASED FOR HIGHER VALUE OF Tc >> CHANGE DIA OR SPACING OF BARS
CHECK FOR TWO WAY SHEAR
AT `d/2' FROM FACE OF COLUMN/PEDESTAL
AREA RESISTING SHEAR 2067800 (sqmm)
EFFECTIVE AREA UNDER COLUMN FOR PUNCHING LOAD 1078800 (sqmm)
Pu1 1149 (kN)
Pu2 0 (kN)
Pu3 0 (kN)
Guiding loadcase for Punching Shear CASE-1
Pu [MAX(Pu1,Pu2,Pu3)] 1149 (kN)
p(avg) 134 (kN/sqm)
LOAD CAUSING PUNCHING SHEAR 1005 (kN)
touV 0.49 (MPa)
touC (ALLOWED) 1.25 (MPa)
CHECK FOR SHEAR SAFE (MPa)

SUMMARY OF FOOTING PROVIDED


LENGTH , BREADTH - mm OF FOOTING PROVIDED 2800 2800 (mm)
TOTAL DEPTH PROVIDED 550 (mm)
Dia. OF BAR IN mm (ALONG X AND Y DIRECTION) 12 12 (mm)
mm - SPACING ALONG X-DIR Y-DIR PROVIDED 150 150 (mm)

E N D

56

You might also like