CALIBRATION CERTIFICATE & INSPECTION CERTIFICATE OF MASTERBALL CALIBRATION UNIT CARL ZEISS INDIA (BANGALORE) PVT. LTD., Page _1__of _1_pages N Certificate No, : 19-999335EP 4 < INSPECTION Control Number : AQ02679700 ELH! CERTIFICATE Date : September 17,2019 ACRE roby Set Customer ; CARL ZEISS INDIA (BANGALORE) PVT. LTD... Equipment Name ; MASTERBALL CALIBRATION UNIT. ‘Type : Quantity: 1 Serial Number ; 999335EP Calibration Date: September 17,2019 Note) Accuracy is guranteed under the 20°C temperature. Certified by Measurement made by TOKYO SEIMITSU CO., LTD. Metrology Company, Quality Assurance Division 4-2, Higashinakanuki-machi, Tsuchiura-city, Ibaraki, Japan Tel: 81(Japan)-29-831-1234 Fax: $1(Japan)-29-831-8051 DT78034-T001-00 1/1 TOKYO SEIMITSU CO.,LTD. Page | __of _2 pages \ Certificate No. : 19-999335EP_ A CERTIFICATE OF Control Number: A002679700 HUES CALIBRATION Date : September 17,2019 eee a Customer : CARL ZEISS INDIA (BANGALORE) PVT. LTD. Equipment Name : MASTERBALL CALIBRATION UNIT Type MC-S65B, Quantity : 1 Serial Number : 999335EP Manufacture ; TOKYO SEIMITSU CO.,LTD Environmental artimay : Temperature : 20°C £0.5°C Humiditty : 50% 10% Calibration Date: September 17,2019 Calibration standard used Vieasaring Speciicaions Conver Calibration Calibration Laboratory Instruments (Type) No. Validity (Manufacturer) Surfeom s1400D 79.2201 | —Mar-2020 [Tokyo Seimitsu Optical Flat 0130 792065 | Mar-2022 |JQA Rondcom ROSA 79-2235 | Dee-2020 [Tokyo Seimitsu Gauge Blocks Class TQ-2026 | Oct-2019 [Tokyo Seimitsu Electronies Micrometer] E-MD-MSI 79-0223 | _Feb-2020 [Tokyo Seimitsu ‘The measuring instruments used are traceable to the national measurement standards controlled by National Institute of Advanced Industrial Science and Technology of Japan. ‘The above product was calibrated in compliance with a quality system registered to ISO 9001. using applicable Tokyo Seimitsu's procedure based on ISO. We certify that the result of the calibration is in accordance with the following pages. This certificate shall not be reproduced except in full, without the written approval of Tokyo Seimitsu Co., Ltd. Higashinakanuki-machi, Tsuchiura-city, Ibaraki, Japan TOKYO SEIMITSU CO., LTD. Metrology Company, Quality Assurance Division Quality Control Manager _—a beste TSQ3833 TOKYO SEIMITSU CO., LTD. Page 2 of 2 pages Type Results of measurement : CERTIFICATE OF CALIBRATION RESULTS OF MEASUREMENT E-MC-S65B Certificate No. : 1 199335EP, Control Number : A002679700 Serial Number : 999335EP Calibration Procedure : TOKYO SEIMITSU engineering standard DT78034-K0O1 according to JIS B07506 Electric micrometer No tem Result Remarks 1 [Diameter of ball 12.7003 mm 2 |Roundness (P-P) 0.03 um 5 |Ftamess of al reference bases 0.3 um TghraTTaTCe * Toetwieen center base and right base passdb Measuring Condit No tem Instrument Measuring condition Block Gauge 1 |Diameter of ball Etccronies Micromet Stylus: 0.8 mm radius Sphere 2 |Roundness (P-P) RONDCOM 654 } Filter: SO (up). Speed: 4 /min MZC : Minimum zone reference cirles 3 |Ftamess of al reference bases Optical Flat eighr arene a [between center base and right bas ne TSQ3835 TOKYO SEIMITSU CO., LTD. a) Jess Page 1 of 2 pages aes Certificate Number TQ19676 Joss 0047 Tois67 ~~ J6880047 Certificate of Calibration Aalepan _ 2019-09 Customer : CARL ZEISS INDIA (BANGALORE) PVT. LTD., “Ades PLOT NO33, JIGANI LINK ROAD, BOMMASANDRA INDSUTRIAL AREA, BANGALORE - 560099, INDIA Object : Gauge blocks Quantity : 3 Serial Number 2 88740,86654,87021 Manufacturer : KOLB & BAUMANN GMBH & CO. KG Calibration em; Length Comparison Measurement with Calibration Procedure(YQ5181 1) by TOKYO SEIMITSU CO., LTD. Reference Standard(s) : —TQ2392,7Q2226 oe - Calibration Method 4-2, Higashinakanuki-machi, Tsuchiura-shi, Ibaraki, Japan TOKYO SEIMITSU CO., LTD. Tsuchiura Plant Calibration Laboratory Calibration Site Environmental Condition 20°C 0.5 °C ( Room temperature ) of Calibration Room = * 50% + 10% ( Relative humidity ) Date of Calibration; September 13, 2019 We certify that the result of calibration is in accordance with the next page. Date of Issue : September 17, 2019 4-2, Higashinakanuki-machi, Tsuchiura-shi, Ibaraki, Japan TOKYO SEIMITSU CO., LTD. Metrology Company, Tsuchiura Plant, Quality Assurance Department Calibration Laboratory ‘This certificate is based on article 144 of the Measurement Law and indicates the result of calibration in accordance with measurement standards traceable to Primary Measurement Standards (National Standards) which realizes the physical units of measurement according to the International System of Units (SI). The accreditation symbol is attestation of which the result of calibration is treceable to Primary Measurement Standards (National Standards). ‘The certificate shall not be reproduced except in full, without the written approval ofthe issuing laboratory, ‘The ealibration laboratory who issued this calibration certificate conforms to ISO/IEC 17025. This calibration certificate was issued by the calibration laboratory accredited by IAJapan who is a signatory to the Mutual Recognition Arrangement (MRA) of International Laboratory Accreditation Cooperation (ILAC) and Asia Pacifie Laboratory Accreditation Cooperation (APLAC). This (These) calibration result(s) may be accepted internationally through ILAC/APLAC MRA. Calibration label is to identify calibration status easily by attaching same information of Calibration Certificate to the calibrated item, TSQaz10P TOKYO SEIMITSU CO.,LTD. ew, ule) css Page 2 of 2 pages seme Certificate Number TQ19676 “eS JOSS 0047 Results of Calibration Nominal Seri) PDevation of each Tengih fom nominal length Gam] Variation length Number | *i€ eal pont [tthe highest point] atthe owes point | in length Remark Zn (mm) ALe ALmax 4Lmin V (um) 4 88740 -0.03 -0.02 -0.08 0.06 16 86654 “0.11 0.11 0.16 0.05 40 87021 0.00 0.00 -0.03 0.03 1) Expanded uncertainty of the calibration Expanded uncertainty of the length deviations from the no from 0.5 mm up to 100 mm U = 0.08 um ‘over 100 mm up to 250 mm. U = (0.05 + £ £2500) um (L Nominal length of calibrated gauge block ( mm )) ‘The above reported expanded uncertainty of the calibration is stated as the standard uncertainty of calibration multiplied by the coverage factor & = 2 such that, for an approximately normal distribution, the coverage probability corresponds to approximately 95 %. 2) The calibrated lengths are values on 20 °C. 3) Material and coefficient of thermal expansion “Material of object is steel with rich carbon and crome. Coefficient of thermal expansion is (11.9 #0.5 )*10°/K (The coefficient is not the actual number but the number by the gage suppliet:) 4) Symbols used inthe table (see the figure below.) Abmax ‘Nominal length at the central point Ln lengths are as follows. Length at the central point Le Length at the highest point Emax erin Deviation from nominal length at the central point ALe=Le-Ln al t Deviation from nominal length at the highest point AL max~£max-Ln L ! Deaton om nominal engh she loves point AL n=Lninen Variation in length VoL max-Lmin=AL max-AL- min ‘Note: Variation in length is only a reference calculated with ALmax and ALmin, nd TSQ32175 TOKYO SEIMITSU CO., LTD. What is JCSS ? Confident Evidence of ‘Traceability and Competence! Japan libration Service System Jucss is... the Calibration Laboratory Accreditation System based on the Japanese Measurement Law in order to ensure the metrological traceability in Japan. IAJapan, National Institute of Technology and Evaluation, Accreditation Body of JCSS assesses and approves the technical competence and conformity to the requirements of ISO/EC17025U1SQ17025) for calibration laboratories. [CSS Calibration Certificate means... JCSS Calibration Certificates issued by JCSS Laboratories, accredited by [AJapan under the ILAC and APLAC MRA, certify formally the metrological traceability to National Measurement Standards of Japan provided by NMIJ. There are no needs to trace back to upper traceability hierarchy if you are with a JCSS Calibration Certificate. A JCSS Calibration Certificate is more confident “Evidence of Traceability" with Technical Competence and an appropriate Measurement Uncertainty than a Certificate with Legal metrology, QMS Certification, and Manufacturers’ self declaration. As lAJapan is one of signatories for ILAC and APLAC MRA, JCSS calibration certificates are equivalent to those of laboratories accredited by other ILAC and APLAC MRA signatories, such as NVLAP, A2LA, UKAS, DKD, NATA, etc. Also for calibration laboratories with overseas metrological traceability, [AJapan assesses ‘them and grants accreditation under “ASNITE program.” |S LAC & APLAC MRA NATA : (Grange 085 Curatn Canta) Sas 1AJapan, National Institute of Technology and Evaluation 2-49-10 Naina Seba ku, Tokyo 151

You might also like