Feedwater heater bypass valves
z Protects the feedwater heater steam jacket in z Allows bypassing of the feedwater heater dur-
case of tube rupture or leakage. ing plant start-up at low turbine load.
z Protects the turbine extraction from excessive z Allows bypassing of the feedwater heater at
backpressure. peak loads to increase power output from the
turbine.
z Allows the feedwater heater to be isolated from
the system for inspection or repair without dis-
rupting the circulation through the plant.
Water valve
Feedwater Steam
Control Valve Turbine
Steam
bypass Water valve
valve
Condenser
HP heater
and bypass
Feedwater
Pump
Applications which provides a tight isolation of the feedwater heater. The
valve body is manufactured of forged steel and is specially
The BTG feedwater preheater bypass valves VHB-3, VHBS- designed to handle the high pressure levels and the thermal
2 and VHBS-3 are designed for use in power plants to allow loads typical of feedwater heater bypass applications.
bypassing of the feedwater heater.
The Kv/Cv-value of the valve is dependent on the pressure
The VHB-3 is installed upstream of the feedwater heater and ratio p1/p2 and must ñ for each valve ñ be calculated by the
the VHBS-2 or VHBS-3 is installed downstream. CCI/BTG computer program, where all throttling points in
The VHBS-2 and VHBS-3 are on-off valves with one plug the valve are taken into consideration. A certified dimen-
and one seat, and VHB-3 is an on-off valve with two seats, sional drawing will be supplied by CCI.
©CCI 2003 1 PS570.06/1en
621en
Function Design
The bypass system is always in stand-by position, ready to The VHB valves are specially designed for the feedwater
act if the feedwater heater malfunctions, which will cause heater bypass application. Reliable function and long ser-
the water level in the heater jacket to increase. By monitor- vice life with a minimum of maintenance are the basic
ing the water level, the feedwater heater bypass system can design criteria for the VHB valve series.
be automatically controlled. When the water level becomes
too high, the feedwater heater bypass valve will open and Body
bypass the feedwater around the heater, which is isolated.
The valve is manufactured from fully machined forgings
Another common malfunction may occur when the pressure with a body shape of smooth design and all body penetra-
in the steam heating line increases. This can be monitored tions circular to prevent asymmetrical stress patterns.
and used as a signal to isolate the heater. The switch-over to
bypass mode is automatic and very fast. Resetting the sys- Connections are adapted to match the connecting piping.
tem to normal operating mode can be done manually or Material is typically carbon steel or CrMo low alloy steel.
automatically depending on specifications.
Bonnet
At the inlet side of the feedwater heater, VHB-3, a three-
way block valve passes the feedwater from the feedwater Pressure seal bonnet is standard which provides a safe and
pump side, either to the feedwater heater (normal operation) tight connection that is easily assembled and disassembled.
or to the bypass line (bypass). A two-way block valve All internal parts can be removed through the bonnet cavity.
VHBS-2 is installed at the feedwater heater outlet side. This Material is typically CrMo low alloy steel.
valve either allows the feedwater flow to pass (normal oper-
ation) or to isolate (bypass). The VHBS-2 is also available Plug
in a three-way version - VHBS-3 - with integrated T-piece.
The VHB valves provide an on-off control function. The
A separate T-piece is thus not required.
plugs are accordingly contoured and designed to minimize
the pressure drop over the trim.
Normal operation
The plug for the VHB-3 is provided with two tight shut-off
The VHB-3 passes the feedwater from the pump to the feed-
areas as this valve has two seats.
water heater (FWH). During normal operation, the plug is
so positioned, that the flow is allowed to pass through the
feedwater heater. At the same time, it keeps the passage Seat
through the by-pass line closed. The internal pressure acting The seats are stellited and integrated with the valve body
on the plug results in a force, which tends to maintain the and the bonnet (only for VHB-3).
plug closed. The actuator is also acting in this direction to
secure a tight shut-off towards the bypass line.
Pressure drop
The feedwater from the FWH to the boiler passes through The pressure drop over each valve can be as low as 0.5 bar
the VHBS-2 or the VHBS-3. The internal pressure in the (8 psi).
valve, acting on the plug, tends to keep the valve open. The
actuator on the VHB is also acting in the same direction to
secure the free passage from the FWH to the boiler.
Bypass operation
When the water level in the heater jacket actuates the level
switch, the feedwater heater bypass system automatically
switches the VHB-3 to close the passage to the FWH and
opens the bypass line. At the same time, VHBS-2 or VHBS-
3 will close the passage to the FWH, and the FWH becomes
isolated from the feedwater flow. Other signals, such as high
pressure in the steam line, will similarly switch the valves.
Manual opening of the bypass system is performed exactly
the same way, except that the signal to open is generated in
the control room from a push-button. Normally the VHB
valves cannot be stroked while being in bypass mode due to
the large pressure differential over the plugs owing to the
force available due to the size of the actuators.
Fig 1 VHB3 - Sectional view
PS570.06/1en 2 ©CCI 2003
621en
Actuating system Pneumatic piston actuators
Three actuating systems are available: Standard piston pneumatic actuators are used. Air is
required at a minimum pressure level of 4 bar (60 psi). The
1 Hydraulic, using the feedwater as fluid system control can be included in the actuator assemblies.
The actuator controls can be configured to provide safe
2 Pneumatic, using standard piston actuators operation (normally bypass mode).
3 Electric, using standard electric actuator.
Electric actuators
The actuating time for the valves can be varied, but typical Standard electric actuators with all on the market available
is approx. 3 sec for hydraulic and pneumatic actuators and voltages. System control to be included in DCS.
approx. 15-25 sec for electric actuators.
Three different versions are available
Hydraulic actuators using the feedwater
1 Automatic bypassing and manual resetting.
The hydraulic actuators are double-acting or single-acting
and use the feedwater as power fluid. No external power is 2 Automatic bypassing and spring-opening upon signal,
required for this system. The control system can be supplied except electric actuators.
such that the valves will fail in the safe mode (normally
bypass mode). 3 Automatic bypassing and resetting upon signal with
hydraulics in both directions.
The actuator control manifold contains both the valves and
the electronics for the control of the system.
Configurations
VHB-3
VHBS-2
VHBS-3
Fig 2 VHB valves in shown bypass position
©CCI 2003 3 PS570.06/1en
621en
Bypass signal from DCS
De-energize for bypass
Air supply
Vent
Solenoid valve
Limit switch, normal operation
Limit switch, bypass mode
Switching valve
(4-way ball valve) Valve for pressurizing
of heater (not CCI scope)
Feedwater heater
Flow control valve
for adjustment of
stroke speed
Limit switch, bypass mode
Limit switch, normal operation
Fig 3 Boiler feedwater heater bypass self acting hydraulic control system shown in bypass mode
PS570.06/1en 4 © CCI 2003
621en
CCI reserves the right to make technical improvements.