Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HALLIBURTON

Compact Burner
The Halliburton Compact Burner has four nozzle ports. • Stable pilot assembly provides the reliable
The nozzles atomize the oil as it exits the burner. ignition source.
The fixed orifice type nozzle has orifices that direct oil • A rupture disc type safety head is located in the short
through a swirl chamber. The oil is atomized as it exits. joint immediately upstream of the burner to protect
An external air blast enhances the atomization process. the system in the event of oil nozzle plug-off and
The combination of the swirl and the air blast produces over-pressure.
the atomization necessary for the most efficient burn.
• Operation of the assembly is simple.
The burner can also accept internal air mix type
nozzles. These are limited to the lower flow rate
applications, but provide a more efficient burn at Operation
those rates. Burner operating sequence:

A water spray ring around the burner head discharges 1. Turn on and ignite the pilot gas.
a water blanket over the flame for cooling and 2. Turn on the compressed air. To be most
black smoke reduction. A pilot system with remote effective, supply pressure should be at least 100 psi.
igniter provides the ignition source for the finely
atomized spray. 3. Slowly direct oil flow to the burner.
4. Turn on the water supply.
Features and Benefits
• The burner is compact, which allows the use of a
minimal sized platform. Monitor oil pressure, water pressure, and air pressure
during the job.
• The assembly is easily serviced on the boom, or may
be carried to the rig for servicing.
CN03947

Compact Burner

Surface Test Equipment


Compact Burner Specifications
Part Number 684.40100
Description 12,000 BOPD Burner
Service H2S*
Oil Connection 3-in. Fig. 602
Maximum Oil Pressure 1,440 psig
Water Requirements 1.25 x Oil rate
Air Requirements 750 scfm @ 100 psig
Swivel Integral
Length 18 in.
in. (cm) (45)
Width 19
in. (cm) (48)
Height 26
in. (cm) (66)
Weight 180
lb (kg) (82)

* Meets requirements of NACE MR-01-75.

Note: Other sizes, configurations, and pressure ratings


are available to meet most applications.

These rating are guidelines only. For more information,


contact your local Halliburton representative.

Sales of Halliburton products and services will be in accord solely with the terms and conditions
contained in the contract between Halliburton and the customer that is applicable to the sale.

H00746 11/97 © 1997 Halliburton Energy Services, Inc. All Rights Reserved Printed in USA